113 related articles for article (PubMed ID: 21392161)
1. Value of fat suppression in gadolinium-enhanced magnetic resonance neuroimaging.
D'Anjou MA; Carmel EN; Tidwell AS
Vet Radiol Ultrasound; 2011; 52(1 Suppl 1):S85-90. PubMed ID: 21392161
[TBL] [Abstract][Full Text] [Related]
2. [Gadolinium-DTPA combined with a fat suppression technique in studies with magnetic resonance at 0.5 T in soft-tissue neoplasms].
Battolla L; Zampa V; Mascalchi M; Falaschi F; Bagnolesi P; Tessa C; Paolicchi A; Bartolozzi C
Radiol Med; 1994 Oct; 88(4):353-8. PubMed ID: 7997603
[TBL] [Abstract][Full Text] [Related]
3. Elimination of chemical shift artifacts of thoracic spine with contrast-enhanced FLAIR imaging with fat suppression at 3.0 T.
Lavdas E; Mavroidis P; Vassiou K; Roka V; Fezoulidis IV; Vlychou M
Magn Reson Imaging; 2010 Dec; 28(10):1535-40. PubMed ID: 20850235
[TBL] [Abstract][Full Text] [Related]
4. Magnetic resonance imaging of musculoskeletal lesions: comparison of three fat-saturation pulse sequences.
Pui MH; Goh PS; Choo HF; Fok EC
Australas Radiol; 1997 May; 41(2):99-102. PubMed ID: 9153802
[TBL] [Abstract][Full Text] [Related]
5. Magnetic resonance imaging enhancement of intervertebral disc disease in 30 dogs following chemical fat saturation.
Freeman AC; Platt SR; Kent M; Howerth E; Holmes SP
J Small Anim Pract; 2012 Feb; 53(2):120-5. PubMed ID: 22250714
[TBL] [Abstract][Full Text] [Related]
6. [Fat-suppressing STIR sequences with and without contrast media in the MRT of ENT tumors].
BrĂ¼ning R; Heuck A; Naegele M; Seelos K; Vahlensieck M; Reiser M
Rofo; 1994 May; 160(5):412-6. PubMed ID: 8173051
[TBL] [Abstract][Full Text] [Related]
7. Gadolinium-enhanced liver magnetic resonance imaging using a 2-point Dixon fat-water separation technique: impact upon image quality and lesion detection.
Rosenkrantz AB; Mannelli L; Kim S; Babb JS
J Comput Assist Tomogr; 2011; 35(1):96-101. PubMed ID: 21160433
[TBL] [Abstract][Full Text] [Related]
8. Improved detection of gadolinium enhancement using magnetization transfer imaging.
Elster AD; Mathews VP; King JC; Hamilton CA
Neuroimaging Clin N Am; 1994 Feb; 4(1):185-92. PubMed ID: 8130949
[TBL] [Abstract][Full Text] [Related]
9. Non-T1-weighted spin-echo MR imaging with contrast material: experimental and preliminary clinical assessment.
Mihara F; Gupta KL; Righi AM
Radiat Med; 1994; 12(5):209-12. PubMed ID: 7863024
[TBL] [Abstract][Full Text] [Related]
10. [The MRT of the orbit: the value of T1-weighted frequency-selective fat saturation at 1.0 and 1.5 tesla].
Link TM; Reimer P; Rummeny EJ; Schuierer G; Grenzebach U; Peters PE
Rofo; 1995 Nov; 163(5):406-10. PubMed ID: 8527754
[TBL] [Abstract][Full Text] [Related]
11. Contrast-enhanced MR imaging in neuroimaging.
Kim BS; Gutierrez JE
Magn Reson Imaging Clin N Am; 2012 Nov; 20(4):649-85. PubMed ID: 23088944
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of residual acoustic schwannoma using gadolinium-DTPA enhanced magnetic resonance imaging with the fat suppression technique.
Battista RA; Bojrab DI; Wang AM
Am J Otol; 1995 Sep; 16(5):628-33. PubMed ID: 8588668
[TBL] [Abstract][Full Text] [Related]
13. [Dixon's technic for fat suppression. Its potential applications in combination with gadolinium-DTPA].
Mascalchi M; Battolla L; Zampa V; Falaschi F; Caramella D; Bartolozzi C
Radiol Med; 1994; 87(1-2):118-26. PubMed ID: 8128013
[TBL] [Abstract][Full Text] [Related]
14. Effect of acquisition time and chemical fat suppression on meningeal enhancement on MR imaging in dogs.
D'Anjou MA; Carmel EN; Blond L; Beauchamp G; Parent J
Vet Radiol Ultrasound; 2012; 53(1):11-20. PubMed ID: 22092922
[TBL] [Abstract][Full Text] [Related]
15. Contrast-enhanced fat-suppression neuroimaging.
Simon JH; Rubinstein D
Neuroimaging Clin N Am; 1994 Feb; 4(1):153-73. PubMed ID: 8130947
[TBL] [Abstract][Full Text] [Related]
16. Contrast-enhanced magnetic resonance imaging in a nontraumatic rabbit osteonecrosis model.
Sakai T; Sugano N; Tsuji T; Miyazawa T; Nakamura N; Haraguchi K; Ochi T; Ohzono K
J Orthop Res; 1999 Sep; 17(5):784-92. PubMed ID: 10569492
[TBL] [Abstract][Full Text] [Related]
17. Use of contrast media in neuroimaging.
Essig M; Dinkel J; Gutierrez JE
Magn Reson Imaging Clin N Am; 2012 Nov; 20(4):633-48. PubMed ID: 23088943
[TBL] [Abstract][Full Text] [Related]
18. Fat suppression in MR imaging: techniques and pitfalls.
Delfaut EM; Beltran J; Johnson G; Rousseau J; Marchandise X; Cotten A
Radiographics; 1999; 19(2):373-82. PubMed ID: 10194785
[TBL] [Abstract][Full Text] [Related]
19. Image subtraction in gadolinium-enhanced MR imaging.
Lee VS; Flyer MA; Weinreb JC; Krinsky GA; Rofsky NM
AJR Am J Roentgenol; 1996 Dec; 167(6):1427-32. PubMed ID: 8956572
[TBL] [Abstract][Full Text] [Related]
20. Diagnostic image quality of gadolinium-enhanced T1-weighted MRI with and without fat saturation in children with retinoblastoma.
Sirin S; Schlamann M; Metz KA; Bornfeld N; Schweiger B; Holdt M; Schuendeln MM; Lohbeck S; Krasny A; Goericke SL
Pediatr Radiol; 2013 Jun; 43(6):716-24. PubMed ID: 23314985
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]