These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 21392761)

  • 61. Correlation of shear to compression for progressive fracture obliquity.
    Lowenberg DW; Nork S; Abruzzo FM
    Clin Orthop Relat Res; 2008 Dec; 466(12):2947-54. PubMed ID: 18820987
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Wire tension versus wire frequency: an experimental Ilizarov frame study.
    La Russa V; Skallerud B; Klaksvik J; Foss OA
    J Biomech; 2010 Aug; 43(12):2327-31. PubMed ID: 20472242
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Direct and indirect loading of the Ilizarov external fixator: the effect on the interfragmentary movements and compressive loads.
    Gessmann J; Baecker H; Jettkant B; Muhr G; Seybold D
    Strategies Trauma Limb Reconstr; 2011 Apr; 6(1):27-31. PubMed ID: 21589679
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Biomechanical comparison of proximal locking plates and blade plates for the treatment of comminuted subtrochanteric femoral fractures.
    Floyd JC; O'Toole RV; Stall A; Forward DP; Nabili M; Shillingburg D; Hsieh A; Nascone JW
    J Orthop Trauma; 2009 Oct; 23(9):628-33. PubMed ID: 19897983
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Wire tension in the Ilizarov system: accuracy of the wire-tensioning device.
    Watson MA; Mathias KJ; Ashcroft GP; Maffulli N; Hukins DW; Shepherd DE
    Proc Inst Mech Eng H; 2005 Sep; 219(5):355-9. PubMed ID: 16225152
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Monitoring in vivo load transmission through an external fixator.
    Grasa J; Gómez-Benito MJ; González-Torres LA; Asiaín D; Quero F; García-Aznar JM
    Ann Biomed Eng; 2010 Mar; 38(3):605-12. PubMed ID: 20052616
    [TBL] [Abstract][Full Text] [Related]  

  • 67. [Biodegradable meniscus fixations: a comparative biomechanical study].
    Seil R; Rupp S; Jurecka C; Georg T; Kohn D
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Feb; 89(1):35-43. PubMed ID: 12610434
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study.
    Horn J; Linke B; Höntzsch D; Gueorguiev B; Schwieger K
    Injury; 2009 Jul; 40(7):767-71. PubMed ID: 19450799
    [TBL] [Abstract][Full Text] [Related]  

  • 69. [Mechanical study of stiffness in LIM-41 external fixator assemblages submitted to torsion strain].
    Bolliger Neto R; Rossi JD; Leivas TP; Basile Júnior R; Pereira CA; Toledo CS
    Rev Hosp Clin Fac Med Sao Paulo; 1998; 53(6):283-6. PubMed ID: 10413942
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Mechanical forces as predictors of healing during tibial lengthening by distraction osteogenesis.
    Aronson J; Harp JH
    Clin Orthop Relat Res; 1994 Apr; (301):73-9. PubMed ID: 8156700
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Tensioning technique and fixator stability of a circular external fixator with threaded fine wires.
    Rickman M; Saleh M; Yang L
    J Biomech; 2006; 39(3):544-50. PubMed ID: 16389095
    [TBL] [Abstract][Full Text] [Related]  

  • 72. The effect of transfixion wire crossing angle on the stiffness of fine wire external fixation: a biomechanical study.
    Roberts CS; Antoci V; Antoci V; Voor MJ
    Injury; 2005 Sep; 36(9):1107-12. PubMed ID: 16098336
    [TBL] [Abstract][Full Text] [Related]  

  • 73. A new treatment for avulsion fracture of the calcaneus using an Ilizarov external fixator.
    Takahashi M; Noda M; Saegusa Y
    Injury; 2013 Nov; 44(11):1640-3. PubMed ID: 23735503
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Axial stiffness and ring deformation of complete and incomplete single ring circular external skeletal fixator constructs.
    Hudson CC; Lewis DD; Cross AR; Horodyski M; Banks SA; Pozzi A
    Am J Vet Res; 2012 Dec; 73(12):2021-8. PubMed ID: 23176434
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Rigidity of unilateral external fixators--a biomechanical study.
    Burgers PT; Van Riel MP; Vogels LM; Stam R; Patka P; Van Lieshout EM
    Injury; 2011 Dec; 42(12):1449-54. PubMed ID: 21703616
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Reduction in wire tension caused by wire clamping and wire tensioner removal: an experimental Ilizarov frame study.
    La Russa V; Skallerud B; Klaksvik J; Foss OA
    Proc Inst Mech Eng H; 2011 Mar; 225(3):220-7. PubMed ID: 21485324
    [TBL] [Abstract][Full Text] [Related]  

  • 77. [Mechanical behavior of Ilizarov ring fixators. Effect of frame parameters on stiffness and consequences for clinical use].
    Duda GN; Kassi JP; Hoffmann JE; Riedt R; Khodadadyan C; Raschke M
    Unfallchirurg; 2000 Oct; 103(10):839-45. PubMed ID: 11098743
    [TBL] [Abstract][Full Text] [Related]  

  • 78. [Biomechanical properties of external Ilizarov fixator with hybrid implants system].
    Filipiak J; Morasiewicz L
    Chir Narzadow Ruchu Ortop Pol; 2005; 70(1):49-56. PubMed ID: 16021824
    [TBL] [Abstract][Full Text] [Related]  

  • 79. The impact of the type of derotation mechanism on the stiffness of the Ilizarov fixator.
    Morasiewicz P; Filipiak J; Konietzko M; Dragan S
    Acta Bioeng Biomech; 2012; 14(1):67-73. PubMed ID: 22742714
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Evaluation of a novel semicircular locking external fixator for treating fractures of long bones: Biomechanical comparison with a circular external fixator.
    Bilgili F; Sardoğan C; Bozdağ E
    Injury; 2022 Apr; 53(4):1353-1360. PubMed ID: 35101257
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.