232 related articles for article (PubMed ID: 21396640)
1. The detection of premalignant colon polyps during colonoscopy is stable throughout the workday.
Freedman JS; Harari DY; Bamji ND; Bodian CA; Kornacki S; Cohen LB; Miller KM; Aisenberg J
Gastrointest Endosc; 2011 Jun; 73(6):1197-206. PubMed ID: 21396640
[TBL] [Abstract][Full Text] [Related]
2. Fewer polyps detected by colonoscopy as the day progresses at a Veteran's Administration teaching hospital.
Chan MY; Cohen H; Spiegel BM
Clin Gastroenterol Hepatol; 2009 Nov; 7(11):1217-23; quiz 1143. PubMed ID: 19631284
[TBL] [Abstract][Full Text] [Related]
3. A morphologic analysis of sessile serrated polyps observed during routine colonoscopy (with video).
Tadepalli US; Feihel D; Miller KM; Itzkowitz SH; Freedman JS; Kornacki S; Cohen LB; Bamji ND; Bodian CA; Aisenberg J
Gastrointest Endosc; 2011 Dec; 74(6):1360-8. PubMed ID: 22018553
[TBL] [Abstract][Full Text] [Related]
4. Adenoma and sessile serrated polyp detection rates: variation by patient sex and colonic segment but not specialty of the endoscopist.
Sanaka MR; Gohel T; Podugu A; Kiran RP; Thota PN; Lopez R; Church JM; Burke CA
Dis Colon Rectum; 2014 Sep; 57(9):1113-9. PubMed ID: 25101608
[TBL] [Abstract][Full Text] [Related]
5. High colonoscopic prevalence of proximal colon serrated polyps in average-risk men and women.
Kahi CJ; Li X; Eckert GJ; Rex DK
Gastrointest Endosc; 2012 Mar; 75(3):515-20. PubMed ID: 22018551
[TBL] [Abstract][Full Text] [Related]
6. Adenoma detection rate is not influenced by full-day blocks, time, or modified queue position.
Lurix E; Hernandez AV; Thoma M; Castro F
Gastrointest Endosc; 2012 Apr; 75(4):827-34. PubMed ID: 22321696
[TBL] [Abstract][Full Text] [Related]
7. Participation by experienced endoscopy nurses increases the detection rate of colon polyps during a screening colonoscopy: a multicenter, prospective, randomized study.
Lee CK; Park DI; Lee SH; Hwangbo Y; Eun CS; Han DS; Cha JM; Lee BI; Shin JE
Gastrointest Endosc; 2011 Nov; 74(5):1094-102. PubMed ID: 21889137
[TBL] [Abstract][Full Text] [Related]
8. Increased adenoma detection rate with system-wide implementation of a split-dose preparation for colonoscopy.
Gurudu SR; Ramirez FC; Harrison ME; Leighton JA; Crowell MD
Gastrointest Endosc; 2012 Sep; 76(3):603-8.e1. PubMed ID: 22732876
[TBL] [Abstract][Full Text] [Related]
9. Prevalence of missed adenomas in patients with inadequate bowel preparation on screening colonoscopy.
Chokshi RV; Hovis CE; Hollander T; Early DS; Wang JS
Gastrointest Endosc; 2012 Jun; 75(6):1197-203. PubMed ID: 22381531
[TBL] [Abstract][Full Text] [Related]
10. Increased polyp detection using narrow band imaging compared with high resolution endoscopy in patients with hyperplastic polyposis syndrome.
Boparai KS; van den Broek FJ; van Eeden S; Fockens P; Dekker E
Endoscopy; 2011 Aug; 43(8):676-82. PubMed ID: 21811939
[TBL] [Abstract][Full Text] [Related]
11. [Does endoscopist fatigue play a role in incomplete colonoscopies and detection of polypoid lesions?].
Borda F; Borda A; Jiménez FJ; Fernández-Urién I; Vila JJ; Zozaya JM
Gastroenterol Hepatol; 2014 Jan; 37(1):9-16. PubMed ID: 24342118
[TBL] [Abstract][Full Text] [Related]
12. High definition colonoscopy vs. standard video endoscopy for the detection of colonic polyps: a meta-analysis.
Subramanian V; Mannath J; Hawkey CJ; Ragunath K
Endoscopy; 2011 Jun; 43(6):499-505. PubMed ID: 21360420
[TBL] [Abstract][Full Text] [Related]
13. Randomized comparison of surveillance intervals after colonoscopic removal of newly diagnosed adenomatous polyps. The National Polyp Study Workgroup.
Winawer SJ; Zauber AG; O'Brien MJ; Ho MN; Gottlieb L; Sternberg SS; Waye JD; Bond J; Schapiro M; Stewart ET
N Engl J Med; 1993 Apr; 328(13):901-6. PubMed ID: 8446136
[TBL] [Abstract][Full Text] [Related]
14. A novel method with significant impact on adenoma detection: combined water-exchange and cap-assisted colonoscopy.
Yen AW; Leung JW; Leung FW
Gastrointest Endosc; 2013 Jun; 77(6):944-8. PubMed ID: 23473001
[TBL] [Abstract][Full Text] [Related]
15. Impact of endoscopist withdrawal speed on polyp yield: implications for optimal colonoscopy withdrawal time.
Simmons DT; Harewood GC; Baron TH; Petersen BT; Wang KK; Boyd-Enders F; Ott BJ
Aliment Pharmacol Ther; 2006 Sep; 24(6):965-71. PubMed ID: 16948808
[TBL] [Abstract][Full Text] [Related]
16. Superiority of a Split-dose Regimen of Sodium Picosulfate/Magnesium Citrate (SPMC) in Comparison to a Prior-day Schedule (AM/PM) for Colonoscopy Preparation. A Randomized Single-blinded Study.
Schulz C; Müller J; Sauter J; Miehlke S; Schmöcker C; Hartmann D; Malfertheiner P; Badiola C
J Gastrointestin Liver Dis; 2016 Sep; 25(3):295-302. PubMed ID: 27689192
[TBL] [Abstract][Full Text] [Related]
17. Trainee participation is associated with increased small adenoma detection.
Buchner AM; Shahid MW; Heckman MG; Diehl NN; McNeil RB; Cleveland P; Gill KR; Schore A; Ghabril M; Raimondo M; Gross SA; Wallace MB
Gastrointest Endosc; 2011 Jun; 73(6):1223-31. PubMed ID: 21481861
[TBL] [Abstract][Full Text] [Related]
18. Self-reported Metabolic Risk Factor Associations with Adenomatous, Sessile Serrated, and Synchronous Adenomatous and Sessile Serrated Polyps.
Santiago CN; Rifkin S; Drewes J; Mullin G; Spence E; Hylind LM; Gills JJ; Kafonek D; Cromwell DM; La Luna L; Giardello F; Sears CL;
Cancer Prev Res (Phila); 2021 Jul; 14(7):697-708. PubMed ID: 33947705
[TBL] [Abstract][Full Text] [Related]
19. Colonoscopic withdrawal times and adenoma detection during screening colonoscopy.
Barclay RL; Vicari JJ; Doughty AS; Johanson JF; Greenlaw RL
N Engl J Med; 2006 Dec; 355(24):2533-41. PubMed ID: 17167136
[TBL] [Abstract][Full Text] [Related]
20. Adenoma detection rates vary minimally with time of day and case rank: a prospective study of 2139 first screening colonoscopies.
Leffler DA; Kheraj R; Bhansali A; Yamanaka H; Neeman N; Sheth S; Sawhney M; Lamont JT; Aronson MD
Gastrointest Endosc; 2012 Mar; 75(3):554-60. PubMed ID: 22341102
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]