These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 21398434)

  • 21. Collection tubes containing citrate stabiliser over-estimate plasma glucose, when compared to other samples undergoing immediate plasma separation.
    Carey R; Lunt H; Heenan HF; Frampton CM; Florkowski CM
    Clin Biochem; 2016 Dec; 49(18):1406-1411. PubMed ID: 27234599
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Rapid blood separation is superior to fluoride for preventing in vitro reductions in measured blood glucose concentration.
    Shi RZ; Seeley ES; Bowen R; Faix JD
    J Clin Pathol; 2009 Aug; 62(8):752-3. PubMed ID: 19638548
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Recentrifugation of Lithium Heparin Gel Separator Tubes up to 8 h after Blood Collection Has No Relevant Influence on the Stability of 30 Routine Biochemical Analytes.
    van Balveren JA; Gemen EFA; Kusters R
    J Appl Lab Med; 2019 Mar; 3(5):864-869. PubMed ID: 31639761
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Elimination of heparin interference during microarray processing of fresh and biobank-archived blood samples.
    Hebels DG; van Herwijnen MH; Brauers KJ; de Kok TM; Chalkiadaki G; Kyrtopoulos SA; Kleinjans JC
    Environ Mol Mutagen; 2014 Jul; 55(6):482-91. PubMed ID: 24740823
    [TBL] [Abstract][Full Text] [Related]  

  • 25. What´s floating on my plasma?
    Cadamuro J; Wiedemann H; Felder TK; Mrazek C; Kipman U; Hannes O; Haschke-Becher E
    Biochem Med (Zagreb); 2017 Jun; 27(2):430-433. PubMed ID: 28694735
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Establishing a practical blood platelet threshold to avoid reporting spurious potassium results due to thrombocytosis.
    Thurlow V; Ozevlat H; Jones SA; Bailey IR
    Ann Clin Biochem; 2005 May; 42(Pt 3):196-9. PubMed ID: 15949154
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Stability of chemical and immunochemical analytes in uncentrifuged plasma samples.
    Leino A; Koivula MK
    Ann Clin Biochem; 2009 Mar; 46(Pt 2):159-61. PubMed ID: 19151172
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Stability of blood potassium: effects of duration, temperature and transport during 10 hours storage of human whole blood in serum and plasma.
    Dromigny JA; Robert E
    Ann Biol Clin (Paris); 2017 Aug; 75(4):369-374. PubMed ID: 28751282
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Rapid centrifugation for routine coagulation testing].
    Boudaoud L; Divaret G; Marie P; Bezeaud A
    Ann Biol Clin (Paris); 2006; 64(4):315-7. PubMed ID: 16829473
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Better Glucose Stability in Serum than in Plasma Samples after 12-h Stay at Room Temperature.
    Grzych G; Pekar JD; Maboudou P
    Diabetes Technol Ther; 2019 Jul; 21(7):413-414. PubMed ID: 31135187
    [No Abstract]   [Full Text] [Related]  

  • 31. [The National Institute of Health quality control program. II. Follow- up studies (phase 2)].
    Loría A
    Rev Invest Clin; 1985; 37(4):385-90. PubMed ID: 4095404
    [No Abstract]   [Full Text] [Related]  

  • 32. Is heparinized plasma suitable for use in routine biochemistry?
    Donnelly JG; Soldin SJ; Nealon DA; Hicks JM
    Pediatr Pathol Lab Med; 1995; 15(4):555-9. PubMed ID: 8597842
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of biochemical variables in plasma samples obtained from healthy dogs and cats by use of standard and microsample blood collection tubes.
    Whittemore JC; Flatland B
    J Am Vet Med Assoc; 2010 Aug; 237(3):288-92. PubMed ID: 20673109
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Whole blood glucose: what are we actually measuring?
    Wiener K
    Ann Clin Biochem; 1995 Jan; 32 ( Pt 1)():1-8. PubMed ID: 7762948
    [No Abstract]   [Full Text] [Related]  

  • 35. Right or wrong sample received for coagulation testing? Tentative algorithms for detection of an incorrect type of sample.
    Lippi G; Salvagno GL; Adcock DM; Gelati M; Guidi GC; Favaloro EJ
    Int J Lab Hematol; 2010 Feb; 32(1 Pt 2):132-8. PubMed ID: 19220524
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [The Seralyzer system. Evaluation of the tests for glucose, urea-N, uric acid, bilirubin, cholesterol and lactate dehydrogenase].
    Burger E; Lapin A; Gabl F
    Med Lab (Stuttg); 1982; 35(6):153-7. PubMed ID: 7162452
    [No Abstract]   [Full Text] [Related]  

  • 37. [Influence of temperature and delayed centrifugation: stability studies of 28 analytes currently analysed].
    Foucher B; Pina G; Desjeux G; Prevosto JM; Chaulet JF; Cheminel V
    Ann Biol Clin (Paris); 2005; 63(1):93-100. PubMed ID: 15689318
    [TBL] [Abstract][Full Text] [Related]  

  • 38. An attempt to reduce the interlaboratory variability of clinical chemistry results in a cooperative clinical investigation programme using a common reference serum.
    Elion-Gerritzen WE; Schippers HM
    Z Klin Chem Klin Biochem; 1974 May; 12(5):253. PubMed ID: 4613042
    [No Abstract]   [Full Text] [Related]  

  • 39. Check-in and sorting of centrifuged serum and lithium-heparin tubes may be unsuitable using a bulk input module.
    Da Rin G; Lippi G
    J Lab Autom; 2014 Oct; 19(5):474-7. PubMed ID: 24865175
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Quality standards for sample processing, transportation, and storage in hemostasis testing.
    Adcock Funk DM; Lippi G; Favaloro EJ
    Semin Thromb Hemost; 2012 Sep; 38(6):576-85. PubMed ID: 22706973
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.