These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
331 related articles for article (PubMed ID: 21403484)
41. Discrepancies between medication orders and infusion pump programming in a paediatric intensive care unit. Russell RA; Murkowski K; Scanlon MC Qual Saf Health Care; 2010 Oct; 19 Suppl 3():i31-5. PubMed ID: 20959316 [TBL] [Abstract][Full Text] [Related]
42. Development of a web-based observational tool for detecting intravenous medication errors with smart infusion pumps. Ohashi K; Dykes P; McIntosh K; Buckley E; Wien M; Kreitzman K; Dumais M; Bates DW Stud Health Technol Inform; 2013; 192():1102. PubMed ID: 23920876 [TBL] [Abstract][Full Text] [Related]
43. JCAHO's National Patient Safety Goal for infusion pump free-flow protection: ECRI's assessment of the protection offered by general-purpose, PCA, and ambulatory pumps. Health Devices; 2004 Dec; 33(12):430-5. PubMed ID: 15675739 [TBL] [Abstract][Full Text] [Related]
44. Accidents and Incidents Related to Intravenous Drug Administration: A Pre-Post Study Following Implementation of Smart Pumps in a Teaching Hospital. Guérin A; Tourel J; Delage E; Duval S; David MJ; Lebel D; Bussières JF Drug Saf; 2015 Aug; 38(8):729-36. PubMed ID: 26108297 [TBL] [Abstract][Full Text] [Related]
45. Intravenous Smart Pumps: Usability Issues, Intravenous Medication Administration Error, and Patient Safety. Giuliano KK Crit Care Nurs Clin North Am; 2018 Jun; 30(2):215-224. PubMed ID: 29724440 [TBL] [Abstract][Full Text] [Related]
46. Smart Use of Smart Infusion Pumps. Aschenbrenner DS Am J Nurs; 2023 Jun; 123(6):18-19. PubMed ID: 37233135 [TBL] [Abstract][Full Text] [Related]
47. Impact of intravenous insulin protocols on hypoglycemia, patient safety, and nursing workload. Sauer P; Van Horn ER Dimens Crit Care Nurs; 2009; 28(3):95-101. PubMed ID: 19387267 [TBL] [Abstract][Full Text] [Related]
48. Safety implications of the dose change alert function in smart infusion pumps on the administration of high-alert medications. Goulding C; Bedard M Can J Crit Care Nurs; 2015; 26(4):23-7. PubMed ID: 26837122 [TBL] [Abstract][Full Text] [Related]
49. System-Level Patient Safety Practices That Aim to Reduce Medication Errors Associated With Infusion Pumps: An Evidence Review. Bacon O; Hoffman L J Patient Saf; 2020 Sep; 16(3S Suppl 1):S42-S47. PubMed ID: 32810000 [TBL] [Abstract][Full Text] [Related]
50. Are you putting patients in danger? Heed warning on infusion pumps. ED Manag; 2001 Jun; 13(6):61-4. PubMed ID: 11406939 [TBL] [Abstract][Full Text] [Related]
51. Programmable infusion pumps in ICUs: an analysis of corresponding adverse drug events. Nuckols TK; Bower AG; Paddock SM; Hilborne LH; Wallace P; Rothschild JM; Griffin A; Fairbanks RJ; Carlson B; Panzer RJ; Brook RH J Gen Intern Med; 2008 Jan; 23 Suppl 1(Suppl 1):41-5. PubMed ID: 18095043 [TBL] [Abstract][Full Text] [Related]
53. An assessment of currently available i.v. push medication delivery systems. Fanikos J; Burger M; Canada T; Ebright P; Fleming J; Harder KA; Pham JC; Sawyer MD; Stevenson JG Am J Health Syst Pharm; 2017 May; 74(9):e230-e235. PubMed ID: 28438828 [No Abstract] [Full Text] [Related]
54. Nursing implications for prevention of adverse drug events in the intensive care unit. George EL; Henneman EA; Tasota FJ Crit Care Med; 2010 Jun; 38(6 Suppl):S136-44. PubMed ID: 20502167 [TBL] [Abstract][Full Text] [Related]