These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 21404086)

  • 1. Collagen-elastin ratio predicts burst pressure of arterial seals created using a bipolar vessel sealing device in a porcine model.
    Sindram D; Martin K; Meadows JP; Prabhu AS; Heath JJ; McKillop IH; Iannitti DA
    Surg Endosc; 2011 Aug; 25(8):2604-12. PubMed ID: 21404086
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of collagen and elastin content on the burst pressure of human blood vessel seals formed with a bipolar tissue sealing system.
    Latimer CA; Nelson M; Moore CM; Martin KE
    J Surg Res; 2014 Jan; 186(1):73-80. PubMed ID: 24035229
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Variation in electrosurgical vessel seal quality along the length of a porcine carotid artery.
    Wyatt HL; Richards R; Pullin R; Yang TJ; Blain EJ; Evans SL
    Proc Inst Mech Eng H; 2016 Mar; 230(3):169-74. PubMed ID: 26743899
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bipolar electrosurgical vessel-sealing device with compressive force monitoring.
    Chen RK; Chastagner MW; Geiger JD; Shih AJ
    J Biomech Eng; 2014 Jun; 136(6):061001. PubMed ID: 24658542
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The impact of atherosclerosis and vascular collagen on energy-based vessel sealing.
    Martin K; Krugman K; Latimer C; Moore C
    J Surg Res; 2013 Dec; 185(2):485-92. PubMed ID: 23866786
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices.
    Newcomb WL; Hope WW; Schmelzer TM; Heath JJ; Norton HJ; Lincourt AE; Heniford BT; Iannitti DA
    Surg Endosc; 2009 Jan; 23(1):90-6. PubMed ID: 18483824
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of a Laparoscopic Ferromagnetic Technology-based Vessel Sealing Device and Comparative Study to Ultrasonic and Bipolar Laparoscopic Devices.
    Chen J; Jensen CR; Manwaring PK; Glasgow RE
    Surg Laparosc Endosc Percutan Tech; 2017 Apr; 27(2):e12-e17. PubMed ID: 28234706
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Differential response of arteries and veins to bipolar vessel sealing: evaluation of a novel reusable device.
    Richter S; Kollmar O; Neunhoeffer E; Schilling MK; Menger MD; Pistorius G
    J Laparoendosc Adv Surg Tech A; 2006 Apr; 16(2):149-55. PubMed ID: 16646707
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safety and effectiveness of a novel generator algorithm for bipolar vessel sealing: a randomised controlled chronic animal study.
    Kraemer B; Tsaousidis C; Kruck S; Schenk M; Scharpf M; Kommoss S; Brucker S; Nuessle D; Enderle MD; Biber U
    BMC Surg; 2019 Nov; 19(1):160. PubMed ID: 31690302
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Perpendicular blood vessel seals are stronger than those made at an angle.
    Voegele AC; Korvick DL; Gutierrez M; Clymer JW; Amaral JF
    J Laparoendosc Adv Surg Tech A; 2013 Aug; 23(8):669-72. PubMed ID: 23755852
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thermal conduction, compression, and electrical current--an evaluation of major parameters of electrosurgical vessel sealing in a porcine in vitro model.
    Wallwiener CW; Rajab TK; Zubke W; Isaacson KB; Enderle M; Schäller D; Wallwiener M
    J Minim Invasive Gynecol; 2008; 15(5):605-10. PubMed ID: 18640881
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Infrared laser sealing of porcine vascular tissues using a 1,470 nm diode laser: Preliminary in vivo studies.
    Cilip CM; Kerr D; Latimer CA; Rosenbury SB; Giglio NC; Hutchens TC; Nau WH; Fried NM
    Lasers Surg Med; 2017 Apr; 49(4):366-371. PubMed ID: 27785787
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of two different energy-based vascular sealing systems for the hemostasis of various types of arteries: a porcine model-evaluation of LigaSure ForceTriad™.
    Katsuno G; Nagakari K; Fukunaga M
    J Laparoendosc Adv Surg Tech A; 2010 Nov; 20(9):747-51. PubMed ID: 20925574
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of multiple use and sterilization on sealing performance of bipolar vessel sealing devices.
    Gardeweg S; Bockstahler B; Duprè G
    PLoS One; 2019; 14(8):e0221488. PubMed ID: 31430327
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.
    Landman J; Kerbl K; Rehman J; Andreoni C; Humphrey PA; Collyer W; Olweny E; Sundaram C; Clayman RV
    J Urol; 2003 Feb; 169(2):697-700. PubMed ID: 12544345
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An evaluation of electrosurgical vessel-sealing devices in biliary tract surgery in a porcine model.
    Hope WW; Padma S; Newcomb WL; Schmelzer TM; Heath JJ; Lincourt AE; Heniford BT; Norton HJ; Martinie JB; Iannitti DA
    HPB (Oxford); 2010 Dec; 12(10):703-8. PubMed ID: 21083796
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the efficacy of the electrosurgical bipolar vessel sealer (LigaSure) devices in sealing lymphatic vessels.
    Novitsky YW; Rosen MJ; Harrell AG; Sing RF; Kercher KW; Heniford BT
    Surg Innov; 2005 Jun; 12(2):155-60. PubMed ID: 16034506
    [TBL] [Abstract][Full Text] [Related]  

  • 18. PlasmaKinetic bipolar vessel sealing: burst pressures and thermal spread in an animal model.
    Pietrow PK; Weizer AZ; L'Esperance JO; Auge BK; Silverstein A; Cummings T; Preminger GM; Albala DM
    J Endourol; 2005; 19(1):107-10. PubMed ID: 15735394
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid sealing and cutting of porcine blood vessels, ex vivo, using a high-power, 1470-nm diode laser.
    Giglio NC; Hutchens TC; Perkins WC; Latimer C; Ward A; Nau WH; Fried NM
    J Biomed Opt; 2014 Mar; 19(3):38002. PubMed ID: 24658792
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of linear and torsional mode ultrasonic coagulating shears for the sealing of medium- to large-sized arteries.
    Ching SS; McMahon MJ
    Surg Endosc; 2007 Jul; 21(7):1165-9. PubMed ID: 17149550
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.