107 related articles for article (PubMed ID: 21414744)
1. Factors affecting flexural strength in cement within cement revisions.
Dang K; Pelletier MH; Walsh WR
J Arthroplasty; 2011 Dec; 26(8):1540-8. PubMed ID: 21414744
[TBL] [Abstract][Full Text] [Related]
2. Physical and mechanical properties of PMMA bone cement reinforced with nano-sized titania fibers.
Khaled SM; Charpentier PA; Rizkalla AS
J Biomater Appl; 2011 Feb; 25(6):515-37. PubMed ID: 20207779
[TBL] [Abstract][Full Text] [Related]
3. Shear properties of bilaminar polymethylmethacrylate cement mantles in revision hip joint arthroplasty.
Weinrauch PC; Bell C; Wilson L; Goss B; Lutton C; Crawford RW
J Arthroplasty; 2007 Apr; 22(3):394-403. PubMed ID: 17400096
[TBL] [Abstract][Full Text] [Related]
4. The role of cement viscosity on cement-bone apposition and strength: an in vitro model with medullary bleeding.
Miller MA; Race A; Gupta S; Higham P; Clarke MT; Mann KA
J Arthroplasty; 2007 Jan; 22(1):109-16. PubMed ID: 17197317
[TBL] [Abstract][Full Text] [Related]
5. Relative influence of composition and viscosity of acrylic bone cement on its apparent fracture toughness.
Lewis G
Biomed Mater Eng; 2000; 10(1):1-11. PubMed ID: 10950202
[TBL] [Abstract][Full Text] [Related]
6. Influence of airborne-particle abrasion on mechanical properties and bond strength of carbon/epoxy and glass/bis-GMA fiber-reinforced resin posts.
Soares CJ; Santana FR; Pereira JC; Araujo TS; Menezes MS
J Prosthet Dent; 2008 Jun; 99(6):444-54. PubMed ID: 18514666
[TBL] [Abstract][Full Text] [Related]
7. In vivo behavior of acrylic bone cement in total hip arthroplasty.
Ries MD; Young E; Al-Marashi L; Goldstein P; Hetherington A; Petrie T; Pruitt L
Biomaterials; 2006 Jan; 27(2):256-61. PubMed ID: 16039712
[TBL] [Abstract][Full Text] [Related]
8. Interfacial strength of novel PMMA/HA/nanoclay bone cement.
Wang CX; Tong J
Biomed Mater Eng; 2008; 18(6):367-75. PubMed ID: 19197113
[TBL] [Abstract][Full Text] [Related]
9. Cement-within-cement revision hip arthroplasty; should it be done?
Li PL; Ingle PJ; Dowell JK
J Bone Joint Surg Br; 1996 Sep; 78(5):809-11. PubMed ID: 8836076
[TBL] [Abstract][Full Text] [Related]
10. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis].
Massin P; Astoin E; Lavaste F
Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057
[TBL] [Abstract][Full Text] [Related]
11. Influence of femoral stem surface finish on the apparent static shear strength at the stem-cement interface.
Zhang H; Brown LT; Blunt LA; Barrans SM
J Mech Behav Biomed Mater; 2008 Jan; 1(1):96-104. PubMed ID: 19627775
[TBL] [Abstract][Full Text] [Related]
12. The effect of surface finish and interstitial fluid on the cement-in-cement interface in revision surgery of the hip.
Rudol G; Wilcox R; Jin Z; Tsiridis E
J Bone Joint Surg Br; 2011 Feb; 93(2):188-93. PubMed ID: 21282757
[TBL] [Abstract][Full Text] [Related]
13. Biomechanical properties of bone cement with addition of cefuroxime antibiotic.
Mohd Fuad D; Masbah O; Shahril Y; Jamari S; Norhamdan MY; Sahrim SH
Med J Malaysia; 2006 Feb; 61 Suppl A():27-9. PubMed ID: 17042225
[TBL] [Abstract][Full Text] [Related]
14. Cemented fixation with PMMA or Bis-GMA resin hydroxyapatite cement: effect of implant surface roughness.
Walsh WR; Svehla MJ; Russell J; Saito M; Nakashima T; Gillies RM; Bruce W; Hori R
Biomaterials; 2004 Sep; 25(20):4929-34. PubMed ID: 15109853
[TBL] [Abstract][Full Text] [Related]
15. Nanoparticulate fillers improve the mechanical strength of bone cement.
Gomoll AH; Fitz W; Scott RD; Thornhill TS; Bellare A
Acta Orthop; 2008 Jun; 79(3):421-7. PubMed ID: 18622848
[TBL] [Abstract][Full Text] [Related]
16. Mechanical effects of the use of vancomycin and meropenem in acrylic bone cement.
Persson C; Baleani M; Guandalini L; Tigani D; Viceconti M
Acta Orthop; 2006 Aug; 77(4):617-21. PubMed ID: 16929439
[TBL] [Abstract][Full Text] [Related]
17. Mixed-mode failure strength of implant-cement interface specimens with varying surface roughness.
Zelle J; Janssen D; Peeters S; Brouwer C; Verdonschot N
J Biomech; 2011 Feb; 44(4):780-3. PubMed ID: 21074772
[TBL] [Abstract][Full Text] [Related]
18. The effect of hydrofluoric acid surface treatment and bond strength of a zirconia veneering ceramic.
Chaiyabutr Y; McGowan S; Phillips KM; Kois JC; Giordano RA
J Prosthet Dent; 2008 Sep; 100(3):194-202. PubMed ID: 18762031
[TBL] [Abstract][Full Text] [Related]
19. Penetration and shear strength of cement-bone interfaces in vivo.
MacDonald W; Swarts E; Beaver R
Clin Orthop Relat Res; 1993 Jan; (286):283-8. PubMed ID: 8425359
[TBL] [Abstract][Full Text] [Related]
20. Precooling of the femoral canal enhances shear strength at the cement-prosthesis interface and reduces the polymerization temperature.
Hsieh PH; Tai CL; Chang YH; Lee MS; Shih HN; Shih CH
J Orthop Res; 2006 Sep; 24(9):1809-14. PubMed ID: 16865715
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]