These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Proximal humeral fractures: the role of calcium sulphate augmentation and extended deltoid splitting approach in internal fixation using locking plates. Somasundaram K; Huber CP; Babu V; Zadeh H Injury; 2013 Apr; 44(4):481-7. PubMed ID: 23199758 [TBL] [Abstract][Full Text] [Related]
3. Proximal humeral fractures treated with an intramedullary cage and plate: clinical and radiographic outcomes at a minimum of 1 year postoperatively. Favorito P; Kohrs B; Donnelly D J Shoulder Elbow Surg; 2021 Dec; 30(12):2786-2794. PubMed ID: 34022366 [TBL] [Abstract][Full Text] [Related]
4. Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. Südkamp N; Bayer J; Hepp P; Voigt C; Oestern H; Kääb M; Luo C; Plecko M; Wendt K; Köstler W; Konrad G J Bone Joint Surg Am; 2009 Jun; 91(6):1320-8. PubMed ID: 19487508 [TBL] [Abstract][Full Text] [Related]
5. Shoulder arthroscopy combined to hardware removal in proximal humeral fractures: a series of 58 cases with a mean follow-up of 2 years. Maroun C; Aliani D; Hass A; Werthel JD; Vidil A; Valenti P Eur J Orthop Surg Traumatol; 2017 Apr; 27(3):317-321. PubMed ID: 28289904 [TBL] [Abstract][Full Text] [Related]
6. [Type C2 proximal humeral fracture fixation using locking-plate with an intramedullary fibular allograft]. Chen X; Chen H; Zou Y; Feng H; Wu J; Zhang J; Peng Z Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Feb; 28(2):201-4. PubMed ID: 24796193 [TBL] [Abstract][Full Text] [Related]
7. Minimally invasive percutaneous plating of proximal humeral shaft fractures with the Proximal Humerus Internal Locking System (PHILOS). Brunner A; Thormann S; Babst R J Shoulder Elbow Surg; 2012 Aug; 21(8):1056-63. PubMed ID: 21872493 [TBL] [Abstract][Full Text] [Related]
8. Locked plating of 3- and 4-part proximal humerus fractures in older patients: the effect of initial fracture pattern on outcome. Solberg BD; Moon CN; Franco DP; Paiement GD J Orthop Trauma; 2009 Feb; 23(2):113-9. PubMed ID: 19169103 [TBL] [Abstract][Full Text] [Related]
9. Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. Owsley KC; Gorczyca JT J Bone Joint Surg Am; 2008 Feb; 90(2):233-40. PubMed ID: 18245580 [TBL] [Abstract][Full Text] [Related]
10. Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus. Matassi F; Angeloni R; Carulli C; Civinini R; Di Bella L; Redl B; Innocenti M Injury; 2012 Nov; 43(11):1939-42. PubMed ID: 22921382 [TBL] [Abstract][Full Text] [Related]
11. Fractures and fracture-dislocations of the proximal humerus: A retrospective analysis of 82 cases treated with the Philos(®) locking plate. Erasmo R; Guerra G; Guerra L Injury; 2014 Dec; 45 Suppl 6():S43-8. PubMed ID: 25457318 [TBL] [Abstract][Full Text] [Related]
13. Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Surgical technique. Konrad G; Bayer J; Hepp P; Voigt C; Oestern H; Kääb M; Luo C; Plecko M; Wendt K; Köstler W; Südkamp N J Bone Joint Surg Am; 2010 Mar; 92 Suppl 1 Pt 1():85-95. PubMed ID: 20194347 [TBL] [Abstract][Full Text] [Related]
14. Calcar comminution as prognostic factor of clinical outcome after locking plate fixation of proximal humeral fractures. Osterhoff G; Hoch A; Wanner GA; Simmen HP; Werner CM Injury; 2012 Oct; 43(10):1651-6. PubMed ID: 22579397 [TBL] [Abstract][Full Text] [Related]
16. Internal fixation of proximal humerus fractures using the locking proximal humerus plate. Plecko M; Kraus A Oper Orthop Traumatol; 2005 Feb; 17(1):25-50. PubMed ID: 16007377 [TBL] [Abstract][Full Text] [Related]
17. Minimally invasive polyaxial locking plate fixation of proximal humeral fractures: a prospective study. Ruchholtz S; Hauk C; Lewan U; Franz D; Kühne C; Zettl R J Trauma; 2011 Dec; 71(6):1737-44. PubMed ID: 22182882 [TBL] [Abstract][Full Text] [Related]
18. Calcar screws and adequate reduction reduced the risk of fixation failure in proximal humeral fractures treated with a locking plate: 190 patients followed for a mean of 3 years. Oppebøen S; Wikerøy AKB; Fuglesang HFS; Dolatowski FC; Randsborg PH J Orthop Surg Res; 2018 Aug; 13(1):197. PubMed ID: 30092807 [TBL] [Abstract][Full Text] [Related]
19. Clinical outcomes of minimally invasive open reduction and internal fixation by screw and washer for displaced greater tuberosity fracture of the humerus. Yoon TH; Choi CH; Choi YR; Oh JT; Chun YM J Shoulder Elbow Surg; 2018 Jun; 27(6):e173-e177. PubMed ID: 29305100 [TBL] [Abstract][Full Text] [Related]
20. Three- and 4-part proximal humeral fracture fixation with an intramedullary cage: 1-year clinical and radiographic outcomes. Hudgens JL; Jang J; Aziz K; Best MJ; Srikumaran U J Shoulder Elbow Surg; 2019 Jun; 28(6S):S131-S137. PubMed ID: 31196507 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]