284 related articles for article (PubMed ID: 21426388)
21. Three-dimensional transesophageal echocardiography of atrial septal defect device closure.
Roberson DA; Cui VW
Curr Cardiol Rep; 2014 Feb; 16(2):453. PubMed ID: 24458293
[TBL] [Abstract][Full Text] [Related]
22. Feasibility of real-time three-dimensional transoesophageal echocardiography for guidance of percutaneous atrial septal defect closure.
Lodato JA; Cao QL; Weinert L; Sugeng L; Lopez J; Lang RM; Hijazi ZM
Eur J Echocardiogr; 2009 Jun; 10(4):543-8. PubMed ID: 19179363
[TBL] [Abstract][Full Text] [Related]
23. Application of real-time three-dimensional transesophageal echocardiography using a matrix array probe for transcatheter closure of atrial septal defect.
Taniguchi M; Akagi T; Watanabe N; Okamoto Y; Nakagawa K; Kijima Y; Toh N; Ohtsuki S; Kusano K; Sano S
J Am Soc Echocardiogr; 2009 Oct; 22(10):1114-20. PubMed ID: 19647397
[TBL] [Abstract][Full Text] [Related]
24. Immediate- and medium-term effects of simultaneous percutaneous corrections of secundum type atrial septal defect combined with pulmonary valve stenosis in local anesthesia and without transesophageal echocardiography guidance.
Xu XD; Ding XY; Liu SX; Bai Y; Zhao XX; Qin YW
J Cardiol; 2015 Jan; 65(1):32-6. PubMed ID: 24842233
[TBL] [Abstract][Full Text] [Related]
25. [Advantages of transesophageal three-dimensional echocardiography as a support in the atrial septal defect closure.].
Contreras AE; Peirone AR
Rev Fac Cien Med Univ Nac Cordoba; 2018 Sep; 75(3):148-149. PubMed ID: 30296020
[No Abstract] [Full Text] [Related]
26. Five-year follow-up of intracardiac echocardiography-assisted transcatheter closure of complex ostium secundum atrial septal defect.
Rigatelli G; Dell' Avvocata F; Cardaioli P; Giordan M; Vassiliev D; Nghia NT; Chen JP
Congenit Heart Dis; 2012; 7(2):103-10. PubMed ID: 22010972
[TBL] [Abstract][Full Text] [Related]
27. Three-dimensional transesophageal echocardiography for guiding percutaneous fontan fenestration closure.
Giannakoulas G; Thanopoulos V
Echocardiography; 2014 Aug; 31(7):E230-1. PubMed ID: 24697836
[No Abstract] [Full Text] [Related]
28. Feasibility, Safety and Accuracy of Echocardiography-Fluoroscopy Imaging Fusion During Percutaneous Atrial Septal Defect Closure in Children.
Hascoët S; Hadeed K; Karsenty C; Dulac Y; Heitz F; Combes N; Chausseray G; Alacoque X; Auriol F; Amedro P; Fraisse A; Acar P
J Am Soc Echocardiogr; 2018 Nov; 31(11):1229-1237. PubMed ID: 30219347
[TBL] [Abstract][Full Text] [Related]
29. Imaging atrial septal defects by real-time three-dimensional transesophageal echocardiography: step-by-step approach.
Saric M; Perk G; Purgess JR; Kronzon I
J Am Soc Echocardiogr; 2010 Nov; 23(11):1128-35. PubMed ID: 20833505
[TBL] [Abstract][Full Text] [Related]
30. Role of 3D transesophageal echocardiography in transcatheter closure of atrial septal aneurysms.
Taha F; Elshedoudy S
Echocardiography; 2019 Oct; 36(10):1884-1894. PubMed ID: 31541598
[TBL] [Abstract][Full Text] [Related]
31. Clinical results of large secundum atrial septal defect closure in adult using percutaneous transcatheter Cocoon atrial septal occluder.
Lairakdomrong K; Srimahachota S; Lertsapcharoen P; Chaipromprasit J; Boonyaratavej S; Kaewsukkho P
J Med Assoc Thai; 2013 Sep; 96(9):1127-34. PubMed ID: 24163987
[TBL] [Abstract][Full Text] [Related]
32. Percutaneous closure of an atrial septal defect and 3-dimensional echocardiography.
Mahmood F; Shakil O; Gerstle JR; Matyal R
J Cardiothorac Vasc Anesth; 2013 Apr; 27(2):400-1. PubMed ID: 23266288
[No Abstract] [Full Text] [Related]
33. Torn atrial septum during transcatheter closure of atrial septal defect visualized by real-time three-dimensional transesophageal echocardiography.
Kijima Y; Taniguchi M; Akagi T; Nakagawa K; Kusano K; Ito H; Sano S
J Am Soc Echocardiogr; 2010 Nov; 23(11):1222.e5-8. PubMed ID: 20472396
[TBL] [Abstract][Full Text] [Related]
34. Transgastric: A forgotten view for atrial septal defect device closure procedures?
Cua CL; Cooper AL; Dutro M; Berman DP
Echocardiography; 2017 Dec; 34(12):1967-1968. PubMed ID: 28898459
[TBL] [Abstract][Full Text] [Related]
35. Transesophageal real time three-dimensional echocardiography in assessment of partial atrioventricular septal defect.
Piatkowski R; Budaj-Fidecka A; Scislo P; Kochanowski J; Spiewak M; Opolski G
Echocardiography; 2009 Oct; 26(9):1092-4. PubMed ID: 19840076
[TBL] [Abstract][Full Text] [Related]
36. [Application of transesophageal echocardiography in intraoperative device closure of secundum atrial septal defects].
Zhang LH; Li ZA; Lin CY; Zhang C
Zhonghua Yi Xue Za Zhi; 2008 Mar; 88(10):691-3. PubMed ID: 18642771
[TBL] [Abstract][Full Text] [Related]
37. An interatrial tunnel: a rare form of atrial septal defects.
Mahmoud HM; Hosny M; Philip P; Wagdy K; Kharabish A; El Mozy W; Yacoub M
Echocardiography; 2016 Nov; 33(11):1781-1784. PubMed ID: 27545447
[TBL] [Abstract][Full Text] [Related]
38. En face view of atrial septal defect by two-dimensional transthoracic echocardiography: comparison to real-time three-dimensional transesophageal echocardiography.
Huang X; Shen J; Huang Y; Zheng Z; Fei H; Hou Y; Xu Y; Huang T; Huang W; Zhang C
J Am Soc Echocardiogr; 2010 Jul; 23(7):714-21. PubMed ID: 20605402
[TBL] [Abstract][Full Text] [Related]
39. [Transthoracic and transesophageal echocardiography in the pre- and postoperative assessment of interatrial communication].
San Román JA; Vilacosta I; Zamorano J; Castillo JA; Rollán MJ; Villanueva MA; Almería C; Sánchez-Harguindey L
Rev Esp Cardiol; 1993 Dec; 46(12):810-5. PubMed ID: 8134694
[TBL] [Abstract][Full Text] [Related]
40. Importance of 3D real time perioperative tee in ASD device embolisation.
Sarvana Babu MS; Aggarwal N; Asha A; Ashok DS; Koshy T
Ann Card Anaesth; 2017; 20(2):278. PubMed ID: 28393802
[No Abstract] [Full Text] [Related]
[Previous] [Next] [New Search]