233 related articles for article (PubMed ID: 21440070)
1. Fast high resolution whole brain T2* weighted imaging using echo planar imaging at 7T.
Zwanenburg JJ; Versluis MJ; Luijten PR; Petridou N
Neuroimage; 2011 Jun; 56(4):1902-7. PubMed ID: 21440070
[TBL] [Abstract][Full Text] [Related]
2. Imaging articular cartilage defects in the ankle joint with 3D fat-suppressed echo planar imaging: comparison with conventional 3D fat-suppressed gradient echo imaging.
Ba-Ssalamah A; Schibany N; Puig S; Herneth AM; Noebauer-Huhmann IM; Trattnig S
J Magn Reson Imaging; 2002 Aug; 16(2):209-16. PubMed ID: 12203770
[TBL] [Abstract][Full Text] [Related]
3. Diffusion-weighted imaging in patients with acute brain ischemia at 3 T: current possibilities and future perspectives comparing conventional echoplanar diffusion-weighted imaging and fast spin echo diffusion-weighted imaging sequences using BLADE (PROPELLER).
Fries P; Runge VM; Kirchin MA; Stemmer A; Naul LG; Wiliams KD; Reith W; Bücker A; Schneider G
Invest Radiol; 2009 Jun; 44(6):351-9. PubMed ID: 19363447
[TBL] [Abstract][Full Text] [Related]
4. Diffusion-weighted 3D multislab echo planar imaging for high signal-to-noise ratio efficiency and isotropic image resolution.
Engström M; Skare S
Magn Reson Med; 2013 Dec; 70(6):1507-14. PubMed ID: 23359357
[TBL] [Abstract][Full Text] [Related]
5. Enhanced sensitivity with fast three-dimensional blood-oxygen-level-dependent functional MRI: comparison of SENSE-PRESTO and 2D-EPI at 3 T.
Neggers SF; Hermans EJ; Ramsey NF
NMR Biomed; 2008 Aug; 21(7):663-76. PubMed ID: 18189337
[TBL] [Abstract][Full Text] [Related]
6. Interleaved snapshot echo planar imaging of mouse brain at 7.0 T.
Guilfoyle DN; Hrabe J
NMR Biomed; 2006 Feb; 19(1):108-15. PubMed ID: 16411168
[TBL] [Abstract][Full Text] [Related]
7. High-resolution depiction of the cranial nerves in the posterior fossa (N III-N XII) with 2D fast spin echo and 3D gradient echo sequences at 3.0 T.
Fischbach F; Müller M; Bruhn H
Clin Imaging; 2009; 33(3):169-74. PubMed ID: 19411020
[TBL] [Abstract][Full Text] [Related]
8. Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display.
Takahara T; Imai Y; Yamashita T; Yasuda S; Nasu S; Van Cauteren M
Radiat Med; 2004; 22(4):275-82. PubMed ID: 15468951
[TBL] [Abstract][Full Text] [Related]
9. Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.
Hussain SM; De Becker J; Hop WC; Dwarkasing S; Wielopolski PA
J Magn Reson Imaging; 2005 Mar; 21(3):219-29. PubMed ID: 15723376
[TBL] [Abstract][Full Text] [Related]
10. Importance of T2*-weighted gradient-echo MRI for diagnosis of cortical vein thrombosis.
Fellner FA; Fellner C; Aichner FT; Mölzer G
Eur J Radiol; 2005 Nov; 56(2):235-9. PubMed ID: 15967621
[TBL] [Abstract][Full Text] [Related]
11. Cerebral microbleeds: accelerated 3D T2*-weighted GRE MR imaging versus conventional 2D T2*-weighted GRE MR imaging for detection.
Vernooij MW; Ikram MA; Wielopolski PA; Krestin GP; Breteler MM; van der Lugt A
Radiology; 2008 Jul; 248(1):272-7. PubMed ID: 18490493
[TBL] [Abstract][Full Text] [Related]
12. Preoperative fast MRI of brain tumors using three-dimensional segmented echo planar imaging compared to three-dimensional gradient echo technique.
Ba-Ssalamah A; Schick S; Herneth AM; Cejna M; Schibany N; Prokesch RW; Wunderbaldinger P; Trattnig S
Magn Reson Imaging; 2000 Jul; 18(6):635-40. PubMed ID: 10930772
[TBL] [Abstract][Full Text] [Related]
13. Magnetic resonance imaging of the canine brain at 3 and 7 T.
Martín-Vaquero P; Da Costa RC; Echandi RL; Tosti CL; Knopp MV; Sammet S
Vet Radiol Ultrasound; 2011; 52(1):25-32. PubMed ID: 21322384
[TBL] [Abstract][Full Text] [Related]
14. Accelerated mapping of magnetic susceptibility using 3D planes-on-a-paddlewheel (POP) EPI at ultra-high field strength.
Stäb D; Bollmann S; Langkammer C; Bredies K; Barth M
NMR Biomed; 2017 Apr; 30(4):. PubMed ID: 27763692
[TBL] [Abstract][Full Text] [Related]
15. Short-scan-time multi-slice diffusion MRI of the mouse cervical spinal cord using echo planar imaging.
Callot V; Duhamel G; Cozzone PJ; Kober F
NMR Biomed; 2008 Oct; 21(8):868-77. PubMed ID: 18574855
[TBL] [Abstract][Full Text] [Related]
16. [Echo-planar FLAIR imaging in patients with brain disorders: comparative studies with turbo-SE T2WI and turbo-FLAIR].
Matoba M; Tonami H; Yokota H; Ayabe K; Okimura T; Yamamoto I
Nihon Igaku Hoshasen Gakkai Zasshi; 1998 Mar; 58(4):129-36. PubMed ID: 9584455
[TBL] [Abstract][Full Text] [Related]
17. Investigating the benefits of multi-echo EPI for fMRI at 7 T.
Poser BA; Norris DG
Neuroimage; 2009 May; 45(4):1162-72. PubMed ID: 19349231
[TBL] [Abstract][Full Text] [Related]
18. Single-shot fast spin-echo diffusion tensor imaging of the brain and spine with head and phased array coils at 1.5 T and 3.0 T.
Xu D; Henry RG; Mukherjee P; Carvajal L; Miller SP; Barkovich AJ; Vigneron DB
Magn Reson Imaging; 2004 Jul; 22(6):751-9. PubMed ID: 15234443
[TBL] [Abstract][Full Text] [Related]
19. In vivo imaging of the human brain at 1.5 T with 0.6-mm isotropic resolution.
Oros-Peusquens AM; Stoecker T; Amunts K; Zilles K; Shah NJ
Magn Reson Imaging; 2010 Apr; 28(3):329-40. PubMed ID: 20117896
[TBL] [Abstract][Full Text] [Related]
20. Surface-based functional magnetic resonance imaging analysis of partial brain echo planar imaging data at 1.5 T.
Jo HJ; Lee JM; Kim JH; Choi CH; Kang DH; Kwon JS; Kim SI
Magn Reson Imaging; 2009 Jun; 27(5):691-700. PubMed ID: 19036544
[TBL] [Abstract][Full Text] [Related]