BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 21440649)

  • 1. Noninvasive cardiac output monitoring with bioreactance as an alternative to invasive instrumentation for preclinical drug evaluation in beagles.
    Heerdt PM; Wagner CL; DeMais M; Savarese JJ
    J Pharmacol Toxicol Methods; 2011; 64(2):111-8. PubMed ID: 21440649
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Non-invasive cardiac output monitoring in neonates using bioreactance: a comparison with echocardiography.
    Weisz DE; Jain A; McNamara PJ; EL-Khuffash A
    Neonatology; 2012; 102(1):61-7. PubMed ID: 22508150
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Noninvasive cardiac output monitoring using bioreactance-based technique in pediatric patients with or without ventricular septal defect during anesthesia: in comparison with echocardiography.
    Sun Y; Wu C; Wu JZ; Wang SS; Bai J; Zhu M; Zhang YQ; Zhang MZ
    Paediatr Anaesth; 2015 Feb; 25(2):167-73. PubMed ID: 25039420
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulmonary arterial thermodilution, femoral arterial thermodilution and bioreactance cardiac output monitoring in a pediatric hemorrhagic hypovolemic shock model.
    Ballestero Y; Urbano J; López-Herce J; Solana MJ; Botrán M; Vinciguerra D; Bellón JM
    Resuscitation; 2012 Jan; 83(1):125-9. PubMed ID: 21763249
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Noninvasive cardiac output measurement using bioreactance in postoperative pediatric patients.
    Vergnaud E; Vidal C; Verchere JM; Taright H; Meyer PG; Carli PA; Orliaguet GA
    Paediatr Anaesth; 2015 Feb; 25(2):160-6. PubMed ID: 24814690
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Non-Invasive Cardiac Output Monitoring in Cardiogenic Shock: The NICOM Study.
    Rali AS; Buechler T; Van Gotten B; Waters A; Shah Z; Haglund N; Sauer A
    J Card Fail; 2020 Feb; 26(2):160-165. PubMed ID: 31751786
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noninvasive cardiac output monitoring (NICOM): a clinical validation.
    Squara P; Denjean D; Estagnasie P; Brusset A; Dib JC; Dubois C
    Intensive Care Med; 2007 Jul; 33(7):1191-1194. PubMed ID: 17458538
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of noninvasive bioreactance with oesophageal Doppler estimation of stroke volume during open abdominal surgery: an observational study.
    Conway DH; Hussain OA; Gall I
    Eur J Anaesthesiol; 2013 Aug; 30(8):501-8. PubMed ID: 23549128
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring.
    Marqué S; Cariou A; Chiche JD; Squara P
    Crit Care; 2009; 13(3):R73. PubMed ID: 19454009
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique.
    Raval NY; Squara P; Cleman M; Yalamanchili K; Winklmaier M; Burkhoff D
    J Clin Monit Comput; 2008 Apr; 22(2):113-9. PubMed ID: 18340540
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noninvasive cardiac output measurements in patients with pulmonary hypertension.
    Rich JD; Archer SL; Rich S
    Eur Respir J; 2013 Jul; 42(1):125-33. PubMed ID: 23100501
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical validation of bioreactance for the measurement of cardiac output in pregnancy.
    Ling HZ; Gallardo-Arozena M; Company-Calabuig AM; Nicolaides KH; Kametas NA
    Anaesthesia; 2020 Oct; 75(10):1307-1313. PubMed ID: 32469423
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparisons between electromagnetic and X-beam transit-time flow measurements for evaluating drug actions on cardiac output in the conscious dog.
    Flynn DM; Wolfgang EA; Raunig DL; Knight DR
    J Pharmacol Toxicol Methods; 2006; 54(3):296-306. PubMed ID: 16531075
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validation of a noninvasive cardiac output monitor in maternal cardiac disease: comparison of NICOM and transthoracic echocardiogram.
    Florio KL; Williams EM; White D; Daming T; Hostetter S; Schrufer-Poland T; Gray R; Schmidt L; Grodzinsky A; Lee J; Rader V; Swearingen K; Nelson L; Patel N; Magalski A; Gosch K; Jones P; Fu Z; Spertus JA
    Am J Obstet Gynecol MFM; 2024 Mar; 6(3):101312. PubMed ID: 38342307
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Major Upper Abdominal Surgery Alters the Calibration of Bioreactance Cardiac Output Readings, the NICOM, When Comparisons Are Made Against Suprasternal and Esophageal Doppler Intraoperatively.
    Huang L; Critchley LAH; Zhang J
    Anesth Analg; 2015 Oct; 121(4):936-945. PubMed ID: 26218863
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of monitoring performance of Bioreactance vs. pulse contour during lung recruitment maneuvers.
    Squara P; Rotcajg D; Denjean D; Estagnasie P; Brusset A
    Crit Care; 2009; 13(4):R125. PubMed ID: 19638227
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous non-invasive hemodynamic monitoring in early onset severe preeclampsia.
    Ackerman-Banks CM; Bhinder J; Eder M; Heerdt P; Sugeng L; Testani J; Alian A; Lipkind H; Velazquez E; Reddy U; Chou JC
    Pregnancy Hypertens; 2023 Dec; 34():27-32. PubMed ID: 37783090
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output.
    Yamada T; Tsutsui M; Sugo Y; Sato T; Akazawa T; Sato N; Yamashita K; Ishihara H; Takeda J
    Anesth Analg; 2012 Jul; 115(1):82-7. PubMed ID: 22467885
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Non-invasive cardiac output measurements based on bioreactance for optimization of atrio- and interventricular delays.
    Khan FZ; Virdee MS; Pugh PJ; Read PA; Fynn SP; Dutka DP
    Europace; 2009 Dec; 11(12):1666-74. PubMed ID: 19910316
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cardiac output measurements during high-risk Cesarean section using electrical bioreactance or arterial waveform analysis: assessment of agreement.
    Gutierrez J; Perry H; Columb M; Bampoe S; Thilaganathan B; Khalil A
    Ultrasound Obstet Gynecol; 2019 Aug; 54(2):232-238. PubMed ID: 30302868
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.