These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 21445834)

  • 1. Changing the release kinetics of gentamicin from poly(D,L-lactide) implant coatings using only one polymer.
    Strobel C; Schmidmaier G; Wildemann B
    Int J Artif Organs; 2011 Mar; 34(3):304-16. PubMed ID: 21445834
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Gentamycin delivered from a PDLLA coating of metallic implants: In vivo and in vitro characterisation for local prophylaxis of implant-related osteomyelitis.
    Vester H; Wildemann B; Schmidmaier G; Stöckle U; Lucke M
    Injury; 2010 Oct; 41(10):1053-9. PubMed ID: 20541756
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Systemic versus local application of gentamicin in prophylaxis of implant-related osteomyelitis in a rat model.
    Lucke M; Wildemann B; Sadoni S; Surke C; Schiller R; Stemberger A; Raschke M; Haas NP; Schmidmaier G
    Bone; 2005 May; 36(5):770-8. PubMed ID: 15794930
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sequential release kinetics of two (gentamicin and BMP-2) or three (gentamicin, IGF-I and BMP-2) substances from a one-component polymeric coating on implants.
    Strobel C; Bormann N; Kadow-Romacker A; Schmidmaier G; Wildemann B
    J Control Release; 2011 Nov; 156(1):37-45. PubMed ID: 21767586
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prophylaxis and treatment of implant-related infections by antibiotic-coated implants: a review.
    Schmidmaier G; Lucke M; Wildemann B; Haas NP; Raschke M
    Injury; 2006 May; 37 Suppl 2():S105-12. PubMed ID: 16651063
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biodegradable controlled antibiotic release devices for osteomyelitis: optimization of release properties.
    Zhang X; Wyss UP; Pichora D; Goosen MF
    J Pharm Pharmacol; 1994 Sep; 46(9):718-24. PubMed ID: 7837040
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Gentamicin coating of metallic implants reduces implant-related osteomyelitis in rats.
    Lucke M; Schmidmaier G; Sadoni S; Wildemann B; Schiller R; Haas NP; Raschke M
    Bone; 2003 May; 32(5):521-31. PubMed ID: 12753868
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vivo quantification of gentamicin released from an implant coating.
    Nast S; Fassbender M; Bormann N; Beck S; Montali A; Lucke M; Schmidmaier G; Wildemann B
    J Biomater Appl; 2016 Jul; 31(1):45-54. PubMed ID: 26865659
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A biodegradable antibiotic delivery system based on poly-(trimethylene carbonate) for the treatment of osteomyelitis.
    Neut D; Kluin OS; Crielaard BJ; van der Mei HC; Busscher HJ; Grijpma DW
    Acta Orthop; 2009 Oct; 80(5):514-9. PubMed ID: 19916681
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of gentamicin and gentamicin-RGD coatings on bone ingrowth and biocompatibility of cementless joint prostheses: an experimental study in rabbits.
    Alt V; Bitschnau A; Böhner F; Heerich KE; Magesin E; Sewing A; Pavlidis T; Szalay G; Heiss C; Thormann U; Hartmann S; Pabst W; Wenisch S; Schnettler R
    Acta Biomater; 2011 Mar; 7(3):1274-80. PubMed ID: 21081183
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transtympanic versus sustained-release administration of gentamicin: kinetics, morphology, and function.
    Hoffer ME; Allen K; Kopke RD; Weisskopf P; Gottshall K; Wester D
    Laryngoscope; 2001 Aug; 111(8):1343-57. PubMed ID: 11568567
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Controlled release of antibiotics from coated orthopedic implants.
    Price JS; Tencer AF; Arm DM; Bohach GA
    J Biomed Mater Res; 1996 Mar; 30(3):281-6. PubMed ID: 8698690
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomimetic multilayer coatings deliver gentamicin and reduce implant-related osteomyelitis in rats.
    Grohmann S; Menne M; Hesse D; Bischoff S; Schiffner R; Diefenbeck M; Liefeith K
    Biomed Tech (Berl); 2019 Aug; 64(4):383-395. PubMed ID: 30173199
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Testing of antibiotic releasing implant coatings to fight bacteria in combat-associated osteomyelitis - an in-vitro study.
    Back DA; Bormann N; Calafi A; Zech J; Garbe LA; Müller M; Willy C; Schmidmaier G; Wildemann B
    Int Orthop; 2016 May; 40(5):1039-47. PubMed ID: 26907873
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gentamicin extended release from an injectable polymeric implant.
    Krasko MY; Golenser J; Nyska A; Nyska M; Brin YS; Domb AJ
    J Control Release; 2007 Jan; 117(1):90-6. PubMed ID: 17150275
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Gentamicin-loaded bioresorbable films for prevention of bacterial infections associated with orthopedic implants.
    Aviv M; Berdicevsky I; Zilberman M
    J Biomed Mater Res A; 2007 Oct; 83(1):10-9. PubMed ID: 17340599
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preparation of gentamicin-loaded electrospun coating on titanium implants and a study of their properties in vitro.
    Li LL; Wang LM; Xu Y; Lv LX
    Arch Orthop Trauma Surg; 2012 Jun; 132(6):897-903. PubMed ID: 22373914
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo-in vitro study of biodegradable and osteointegrable gentamicin bone implants.
    Sánchez E; Baro M; Soriano I; Perera A; Evora C
    Eur J Pharm Biopharm; 2001 Sep; 52(2):151-8. PubMed ID: 11522480
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Gentamicin coating of plasma chemical oxidized titanium alloy prevents implant-related osteomyelitis in rats.
    Diefenbeck M; Schrader C; Gras F; Mückley T; Schmidt J; Zankovych S; Bossert J; Jandt KD; Völpel A; Sigusch BW; Schubert H; Bischoff S; Pfister W; Edel B; Faucon M; Finger U
    Biomaterials; 2016 Sep; 101():156-64. PubMed ID: 27294535
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrophoretic deposition of gentamicin-loaded bioactive glass/chitosan composite coatings for orthopaedic implants.
    Pishbin F; Mouriño V; Flor S; Kreppel S; Salih V; Ryan MP; Boccaccini AR
    ACS Appl Mater Interfaces; 2014 Jun; 6(11):8796-806. PubMed ID: 24827466
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.