These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 2144799)

  • 21. Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterization.
    Hodgson JM; LeGrand V; Bates ER; Mancini GB; Aueron FM; O'Neill WW; Simon SB; Beauman GJ; LeFree MT; Vogel RA
    Am J Cardiol; 1985 Jan; 55(1):188-93. PubMed ID: 3881002
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Determination of coronary flow reserve by digital angiography: validation of a practical method not requiring power injection or electrocardiographic gating.
    Gurley JC; Nissen SE; Elion JL; Booth DC; DeMaria AN
    J Am Coll Cardiol; 1990 Jul; 16(1):190-7. PubMed ID: 2358592
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Resistance to flow of arterial Y-grafts 6 months after coronary artery bypass surgery.
    Glineur D; Noirhomme P; Reisch J; El Khoury G; Astarci P; Hanet C
    Circulation; 2005 Aug; 112(9 Suppl):I281-5. PubMed ID: 16159832
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Adenosine-induced coronary vasodilation during transesophageal Doppler echocardiography. Rapid and safe measurement of coronary flow reserve ratio can predict significant left anterior descending coronary stenosis.
    Redberg RF; Sobol Y; Chou TM; Malloy M; Kumar S; Botvinick E; Kane J
    Circulation; 1995 Jul; 92(2):190-6. PubMed ID: 7600650
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effect of perfusion pressure distal to a coronary stenosis on transmural myocardial blood flow.
    Bache RJ; Schwartz JS
    Circulation; 1982 May; 65(5):928-35. PubMed ID: 7074755
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Coronary flow reserve calculated from pressure measurements in humans. Validation with positron emission tomography.
    De Bruyne B; Baudhuin T; Melin JA; Pijls NH; Sys SU; Bol A; Paulus WJ; Heyndrickx GR; Wijns W
    Circulation; 1994 Mar; 89(3):1013-22. PubMed ID: 8124786
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Estimation of coronary flow reserve by intracoronary Doppler flow probes and digital angiography.
    Graham SP; Cohen MD; Hodgson JM
    Cathet Cardiovasc Diagn; 1990 Mar; 19(3):214-21. PubMed ID: 2138510
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparison between regional myocardial perfusion reserve and coronary flow reserve in the canine heart.
    Geldof MJ; Schalij MJ; Manger Cats V; van der Zwet PM; Steendijk P; van der Velde ET; Nagtegaal EM; Reiber JH; Bruschke AV
    Eur Heart J; 1995 Dec; 16(12):1860-71. PubMed ID: 8682019
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The diastolic hyperemic flow versus pressure relation. A new index of coronary stenosis severity and flow reserve.
    Mancini GB; McGillem MJ; DeBoe SF; Gallagher KP
    Circulation; 1989 Oct; 80(4):941-50. PubMed ID: 2791252
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Mechanism of remote myocardial ischaemia after coronary occlusion in open chest dogs.
    Gascho JA; Flanagan TL; Jennings CF; Beller GA
    Cardiovasc Res; 1988 Jun; 22(6):398-406. PubMed ID: 3224352
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Instantaneous hyperemic flow-versus-pressure slope index. Microsphere validation of an alternative to measures of coronary reserve.
    Mancini GB; Cleary RM; DeBoe SF; Moore NB; Gallagher KP
    Circulation; 1991 Aug; 84(2):862-70. PubMed ID: 1860227
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Residual coronary reserve despite decreased resting blood flow in patients with critical coronary lesions. A study by technetium-99m human albumin microsphere myocardial scintigraphy.
    Parodi O; Sambuceti G; Roghi A; Testa R; Inglese E; Pirelli S; Spinelli F; Campolo L; L'Abbate A
    Circulation; 1993 Feb; 87(2):330-44. PubMed ID: 8425282
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Native collaterals in the development of collateral circulation after chronic coronary stenosis in mongrel dogs.
    Schwarz F; Wagner HO; Sesto M; Hofmann M; Schaper W; Kübler W
    Circulation; 1982 Aug; 66(2):303-8. PubMed ID: 7094241
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Coronary vasodilator reserve persists despite tachycardia and myocardial ischemia.
    Bristow JD; McFalls EO; Anselone CG; Pantely GA
    Am J Physiol; 1987 Aug; 253(2 Pt 2):H422-31. PubMed ID: 3618815
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Coronary arterial flow-velocity dynamics in children with angiographically normal coronary arteries.
    Hamaoka K; Onouchi Z; Ohmochi Y; Sakata K
    Circulation; 1995 Nov; 92(9):2457-62. PubMed ID: 7586345
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Limits of detection of regional differences in vasodilated flow in viable myocardium by first-pass magnetic resonance perfusion imaging.
    Klocke FJ; Simonetti OP; Judd RM; Kim RJ; Harris KR; Hedjbeli S; Fieno DS; Miller S; Chen V; Parker MA
    Circulation; 2001 Nov; 104(20):2412-6. PubMed ID: 11705817
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Coronary vasodilator reserve in ischemic myocardium of the exercising dog.
    Laxson DD; Dai XZ; Homans DC; Bache RJ
    Circulation; 1992 Jan; 85(1):313-22. PubMed ID: 1728463
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Measurement of absolute epicardial coronary artery flow and flow reserve with breath-hold cine phase-contrast magnetic resonance imaging.
    Clarke GD; Eckels R; Chaney C; Smith D; Dittrich J; Hundley WG; NessAiver M; Li HF; Parkey RW; Peshock RM
    Circulation; 1995 May; 91(10):2627-34. PubMed ID: 7743626
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Persistence of coronary vasodilator reserve despite functionally significant flow reduction.
    Aversano T; Becker LC
    Am J Physiol; 1985 Mar; 248(3 Pt 2):H403-11. PubMed ID: 3156514
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Use and limitations of magnetic resonance phase-contrast assessment of coronary flow reserve in a model of collateral dependence.
    Malik JA; Rubal BJ; Clarke GD; Dick EJ; Ward JA; Harris RA
    Comp Med; 2005 Aug; 55(4):317-25. PubMed ID: 16158907
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.