These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 21452734)

  • 1. A variable echo-number method for estimating R2 in MRI-based polymer gel dosimetry.
    Watanabe Y; Kubo H
    Med Phys; 2011 Feb; 38(2):975-82. PubMed ID: 21452734
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel quantification method for low-density gel dosimeter.
    Nedaie HA; Pak F; Vaezzadeh V; Eqlimi E; Takavar A; Saligheh Rad HR; Mosleh Shirazi MA; Mirheydari M
    J Cancer Res Ther; 2018; 14(2):292-299. PubMed ID: 29516909
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dose uncertainty and resolution of polymer gel dosimetry using an MRI guided radiation therapy system's onboard 0.35 T scanner.
    Maraghechi B; Gach HM; Setianegara J; Yang D; Li HH
    Phys Med; 2020 May; 73():8-12. PubMed ID: 32279048
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters.
    Ibbott GS; Maryanski MJ; Eastman P; Holcomb SD; Zhang Y; Avison RG; Sanders M; Gore JC
    Int J Radiat Oncol Biol Phys; 1997 Jul; 38(5):1097-103. PubMed ID: 9276377
    [TBL] [Abstract][Full Text] [Related]  

  • 5. MRI-based polymer gel dosimetry for validating plans with multiple matrices in Gamma Knife stereotactic radiosurgery.
    Gopishankar N; Watanabe Y; Subbiah V
    J Appl Clin Med Phys; 2011 Jan; 12(2):3333. PubMed ID: 21587176
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An evaluation of the TSE MR sequence for time efficient data acquisition in polymer gel dosimetry of applications involving high doses and steep dose gradients.
    Baras P; Seimenis I; Sandilos P; Vlahos L; Bieganski T; Georgiou E; Pantelis E; Papagiannis P; Sakelliou L
    Med Phys; 2005 Nov; 32(11):3339-45. PubMed ID: 16370420
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of TSE, TGSE, and CPMG measurement techniques for MR polymer gel dosimetry.
    Bankamp A; Schad LR
    Magn Reson Imaging; 2003 Oct; 21(8):929-39. PubMed ID: 14599544
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The application of polymer gel dosimeters to dosimetry for targeted radionuclide therapy.
    Gear JI; Flux GD; Charles-Edwards E; Partridge M; Cook G; Ott RJ
    Phys Med Biol; 2006 Jul; 51(14):3503-16. PubMed ID: 16825745
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of water molecular self-diffusion on quantitative high-resolution MRI polymer gel dosimetry.
    Hurley C; De Deene Y; Meder R; Pope JM; Baldock C
    Phys Med Biol; 2003 Sep; 48(18):3043-58. PubMed ID: 14529209
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dose resolution in radiotherapy polymer gel dosimetry: effect of echo spacing in MRI pulse sequence.
    Baldoc C; Lepage M; Bäck SA; Murry PJ; Jayasekera PM; Porter D; Kron T
    Phys Med Biol; 2001 Feb; 46(2):449-60. PubMed ID: 11229725
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy.
    Low DA; Dempsey JF; Venkatesan R; Mutic S; Markman J; Mark Haacke E; Purdy JA
    Med Phys; 1999 Aug; 26(8):1542-51. PubMed ID: 10501054
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 3D evaluation of 3DVH program using BANG3 polymer gel dosimeter.
    Watanabe Y; Nakaguchi Y
    Med Phys; 2013 Aug; 40(8):082101. PubMed ID: 23927338
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Basic investigations on the performance of a normoxic polymer gel with tetrakis-hydroxy-methyl-phosphonium chloride as an oxygen scavenger: reproducibility, accuracy, stability, and dose rate dependence.
    Bayreder C; Georg D; Moser E; Berg A
    Med Phys; 2006 Jul; 33(7):2506-18. PubMed ID: 16898454
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Introducing gel dosimetry in a clinical environment: customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy.
    Crescenti RA; Scheib SG; Schneider U; Gianolini S
    Med Phys; 2007 Apr; 34(4):1286-97. PubMed ID: 17500460
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetization transfer imaging for polymer gel dosimetry.
    Lepage M; McMahon K; Galloway GJ; De Deene Y; Bäck SA; Baldock C
    Phys Med Biol; 2002 Jun; 47(11):1881-90. PubMed ID: 12108773
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of three-dimensional polymer gel dosimetry using X-ray CT and R2 MRI.
    Kawamura H; Sakae T; Terunuma T; Ishida M; Shibata Y; Matsumura A
    Appl Radiat Isot; 2013 Jul; 77():94-102. PubMed ID: 23542121
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of high field magnetic resonance microimaging in polymer gel dosimetry.
    Skorupa A; Woźnica A; Ciszek M; Staniszewski M; Kijonka M; Kozicki M; Woźniak B; Orlef A; Polański A; Boguszewicz Ł; Sokół M
    Med Phys; 2020 Aug; 47(8):3600-3613. PubMed ID: 32301510
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimization of multiple spin-echo sequences for 3D polymer gel dosimetry.
    De Deene Y; Baldock C
    Phys Med Biol; 2002 Sep; 47(17):3117-41. PubMed ID: 12361214
    [TBL] [Abstract][Full Text] [Related]  

  • 19. On the validity of 3D polymer gel dosimetry: III. MRI-related error sources.
    Vandecasteele J; De Deene Y
    Phys Med Biol; 2013 Jan; 58(1):63-85. PubMed ID: 23221352
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polymer gel dosimetry for measuring the dose near thin high-Z materials irradiated with high energy photon beams.
    Warmington LL; Gopishankar N; Broadhurst JH; Watanabe Y
    Med Phys; 2016 Dec; 43(12):6525. PubMed ID: 27908188
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.