108 related articles for article (PubMed ID: 21458652)
1. Retentive force and magnetic flux leakage of magnetic attachment in various keeper and magnetic assembly combinations.
Hasegawa M; Umekawa Y; Nagai E; Ishigami T
J Prosthet Dent; 2011 Apr; 105(4):266-71. PubMed ID: 21458652
[TBL] [Abstract][Full Text] [Related]
2. [Measurements of the flux densities of static magnetic fields generated by two types of dental magnetic attachments and their retentive forces].
Xu C; Chao YL; Du L; Yang L
Sichuan Da Xue Xue Bao Yi Xue Ban; 2004 May; 35(3):412-5. PubMed ID: 15181852
[TBL] [Abstract][Full Text] [Related]
3. Influence of repeated insertion-removal cycles on the force and magnetic flux leakage of magnetic attachments: an in vitro study.
Hao Z; Chao Y; Meng Y; Yin H
J Prosthet Dent; 2014 Aug; 112(2):235-40. PubMed ID: 24439071
[TBL] [Abstract][Full Text] [Related]
4. Attachment systems for mandibular single-implant overdentures: an in vitro retention force investigation on different designs.
Alsabeeha N; Atieh M; Swain MV; Payne AG
Int J Prosthodont; 2010; 23(2):160-6. PubMed ID: 20305857
[TBL] [Abstract][Full Text] [Related]
5. [The measurement of retentive force of laser-melted and cast post-keepers of Magfit magnetic attachments].
Yang L; Du L; Lin Y
Hua Xi Kou Qiang Yi Xue Za Zhi; 2003 Oct; 21(5):386-8. PubMed ID: 14650998
[TBL] [Abstract][Full Text] [Related]
6. [The measurement of retentive forces in mandibular complete overdenture with Magfit magnetic attachments].
Du L; Xu C; Chao Y
Hua Xi Kou Qiang Yi Xue Za Zhi; 2003 Oct; 21(5):366-8. PubMed ID: 14650991
[TBL] [Abstract][Full Text] [Related]
7. Dental magnetic attachment: toward third generation devices.
Tegawa Y; Kinouchi Y
IEEE Trans Biomed Eng; 2008 Mar; 55(3):1185-90. PubMed ID: 18334412
[TBL] [Abstract][Full Text] [Related]
8. Comparative study of four retentive anchor systems for implant supported overdentures--retention force changes.
Bayer S; Steinheuser D; Grüner M; Keilig L; Enkling N; Stark H; Mues S
Gerodontology; 2009 Dec; 26(4):268-72. PubMed ID: 19371390
[TBL] [Abstract][Full Text] [Related]
9. Magnetic denture retention systems: inexpensive and efficient.
Gillings BR
Int Dent J; 1984 Sep; 34(3):184-97. PubMed ID: 6384053
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of leakage flux out of a dental magnetic attachment.
Nishida M; Tegawa Y; Kinouchi Y
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():3520-3. PubMed ID: 18002756
[TBL] [Abstract][Full Text] [Related]
11. Comparison and evaluation of leakage flux on various types of dental magnetic attachment.
Nishida M; Tegawa Y; Kinouchi Y
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():2813-6. PubMed ID: 19163290
[TBL] [Abstract][Full Text] [Related]
12. Development of a self-adjusting magnetic attachment for implant overdentures.
Maeda Y; Yang TC; Kinoshita Y
Int J Prosthodont; 2011; 24(3):241-3. PubMed ID: 21519571
[TBL] [Abstract][Full Text] [Related]
13. [Establishment of two-dimensional magnetic field finite element analysis model of cup-yoke-type magnetic attachment].
Lin L; Zhao Y; Gu J; Liang D
Hua Xi Kou Qiang Yi Xue Za Zhi; 2002 Oct; 20(5):377-9. PubMed ID: 12607373
[TBL] [Abstract][Full Text] [Related]
14. Maximum dislodging forces of implant overdenture stud attachments.
Petropoulos VC; Smith W
Int J Oral Maxillofac Implants; 2002; 17(4):526-35. PubMed ID: 12182295
[TBL] [Abstract][Full Text] [Related]
15. The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: initial retention values.
Michelinakis G; Barclay CW; Smith PW
Int J Prosthodont; 2006; 19(5):507-12. PubMed ID: 17323731
[TBL] [Abstract][Full Text] [Related]
16. Overdenture retention and stabilization with ball-and-socket attachments: principles and technique.
Banton B; Henry MD
J Dent Technol; 1997 Sep; 14(7):14-20. PubMed ID: 9524489
[TBL] [Abstract][Full Text] [Related]
17. Clinical application of dental prosthesis with magnetic attachment to a patient with cerebral palsy.
Marukawa Y; Akiyama S; Morisaki I
J Osaka Univ Dent Sch; 1994 Dec; 34():45-9. PubMed ID: 8935093
[TBL] [Abstract][Full Text] [Related]
18. [Retention of Pt-Co magnet for dental prosthesis].
Okuno O; Nakano T; Hamanaka H; Kinouchi Y
Tokyo Ika Shika Daigaku Iyo Kizai Kenkyusho Hokoku; 1989; 23():1-5. PubMed ID: 2488956
[TBL] [Abstract][Full Text] [Related]
19. Retention forces of spherical attachments as a function of implant and matrix angulation in mandibular overdentures: an in vitro study.
Ortegón SM; Thompson GA; Agar JR; Taylor TD; Perdikis D
J Prosthet Dent; 2009 Apr; 101(4):231-8. PubMed ID: 19328276
[TBL] [Abstract][Full Text] [Related]
20. Use of the integral implant for overdenture stabilization.
Block MS; Kent JN; Finger IM
Int J Oral Maxillofac Implants; 1990; 5(2):140-7. PubMed ID: 2133339
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]