These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
171 related articles for article (PubMed ID: 21475945)
21. Thiocyanate ion-selective PVC membrane electrode based on N,N'-ethylene-bis(4-methylsalicylidineiminato)nickel(II). Mazloum Ardakani M; Jamshidpour M; Naeimi H; Moradi L Anal Sci; 2006 Sep; 22(9):1221-6. PubMed ID: 16966813 [TBL] [Abstract][Full Text] [Related]
22. Determination of SCN- in urine and saliva of smokers and non-smokers by SCN(-)-selective polymeric membrane containing a nickel(II)-azamacrocycle complex coated on a graphite electrode. Ganjali MR; Yousefi M; Javanbakht M; Poursaberi T; Salavati-Niasari M; Hajiagha-Babaei L; Latifi E; Shamsipur M Anal Sci; 2002 Aug; 18(8):887-92. PubMed ID: 12200834 [TBL] [Abstract][Full Text] [Related]
23. The first use of a Rh(III) complex as a novel ionophore for thiocyanate-selective polymeric membrane electrodes. Shamsipur M; Ershad S; Samadi N; Rezvani AR; Haddadzadeh H Talanta; 2005 Feb; 65(4):991-7. PubMed ID: 18969900 [TBL] [Abstract][Full Text] [Related]
24. A Schiff base complex of Zn(II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion. Shamsipur M; Yousefi M; Hosseini M; Ganjali MR; Sharghi H; Naeimi H Anal Chem; 2001 Jul; 73(13):2869-74. PubMed ID: 11467529 [TBL] [Abstract][Full Text] [Related]
25. Optimization of polymeric triiodide membrane electrode based on clozapine-triiodide ion-pair using experimental design. Farhadi K; Bahram M; Shokatynia D; Salehiyan F Talanta; 2008 Jul; 76(2):320-6. PubMed ID: 18585284 [TBL] [Abstract][Full Text] [Related]
26. Highly selective thiocyanate membrane electrode based on butane-2,3-dione bis(salicylhydrazonato)zinc(II) complex. Ardakani MM; Sadeghi A; Salavati-Niasari M Talanta; 2005 May; 66(4):837-43. PubMed ID: 18970061 [TBL] [Abstract][Full Text] [Related]
27. Synthesis and characterization of bis nitrato[4-hydroxyacetophenonesemicarbazone) nickel(II) complex as ionophore for thiocyanate-selective electrode. Chandra S; Hooda S; Tomar PK; Malik A; Kumar A; Malik S; Gautam S Mater Sci Eng C Mater Biol Appl; 2016 May; 62():18-27. PubMed ID: 26952393 [TBL] [Abstract][Full Text] [Related]
28. Fabrication of coated graphite electrode for the selective determination of europium (III) ions. Upadhyay A; Singh AK; Bandi KR; Jain AK Talanta; 2013 Oct; 115():569-76. PubMed ID: 24054634 [TBL] [Abstract][Full Text] [Related]
29. Coated-wire copper(II)-selective electrode based on phenylglyoxal-alpha-monoxime ionophore. Firooz AR; Mazloum M; Safari J; Amini MK Anal Bioanal Chem; 2002 Mar; 372(5-6):718-22. PubMed ID: 11941444 [TBL] [Abstract][Full Text] [Related]
30. Design and construction of new potentiometric sensors for determination of Al3+ ion based on (Z)-2-(2-methyl benzylidene)-1-(2,4-dinitrophenyl) hydrazine. Mizani F; Salmanzadeh Ardabili S; Ganjaliab MR; Faridbod F; Payehghadr M; Azmoodeh M Mater Sci Eng C Mater Biol Appl; 2015 Apr; 49():861-868. PubMed ID: 25687018 [TBL] [Abstract][Full Text] [Related]
32. A novel flow injection potentiometric graphite coated ion-selective electrode for the low level determination of uranyl ion. Shamsipur M; Mizani F; Mousavi MF; Alizadeh N; Alizadeh K; Eshghi H; Karami H Anal Chim Acta; 2007 Apr; 589(1):22-32. PubMed ID: 17397648 [TBL] [Abstract][Full Text] [Related]
33. A new Zn(II)-selective potentiometric sensor based on 4-tert-butylcalix[4]arene in PVC matrix. Gupta VK; Goyal RN; Al Khayat M; Kumar P; Bachheti N Talanta; 2006 Jul; 69(5):1149-55. PubMed ID: 18970696 [TBL] [Abstract][Full Text] [Related]
34. Sulfate-selective PVC membrane electrode based on a strontium Schiff's base complex. Ganjali MR; Norouzi P; Gol-Mohammadi M; Mizani F; Poursaberi T; Salavati-Niasari M; Shamsipur M; Hosseini M; Javanbakht M Ann Chim; 2003; 93(7-8):679-90. PubMed ID: 12940601 [TBL] [Abstract][Full Text] [Related]
35. Nickel analysis in real samples by Ni2+ selective PVC membrane electrode based on a new Schiff base. Tomar PK; Chandra S; Malik A; Kumar A Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):4978-84. PubMed ID: 24094213 [TBL] [Abstract][Full Text] [Related]
36. Silver(I)-selective electrode based on [Bz2Oxo4(18)dieneS4] tetrathia macrocyclic carrier. Singh AK; Saxena P Anal Bioanal Chem; 2006 May; 385(1):90-5. PubMed ID: 16601953 [TBL] [Abstract][Full Text] [Related]
37. A tetra-coordinate nickel(II) complex as neutral carrier for nitrate-selective PVC membrane electrode. Asghari AR; Amini MK; Mansour HR; Salavati-Niasari M Talanta; 2003 Nov; 61(4):557-63. PubMed ID: 18969218 [TBL] [Abstract][Full Text] [Related]
38. A copper ion-selective electrode with high selectivity prepared by sol-gel and coated wire techniques. Mazloum Ardakani M; Salavati-Niasari M; Khayat Kashani M; Ghoreishi SM Anal Bioanal Chem; 2004 Mar; 378(6):1659-65. PubMed ID: 15214432 [TBL] [Abstract][Full Text] [Related]
39. A coated wire-type lead(II) ion-selective electrode based on a phosphorylated calix[4]arene derivative. Yaftian MR; Rayati S; Emadi D; Matt D Anal Sci; 2006 Aug; 22(8):1075-8. PubMed ID: 16896245 [TBL] [Abstract][Full Text] [Related]
40. A Ho(III) potentiometric polymeric membrane sensor based on a new four dentate neutral ion carrier. Zamani HA; Zanganeh-Asadabadi A; Rohani M; Zabihi MS; Fadaee J; Ganjali MR; Faridbod F; Meghdadi S Mater Sci Eng C Mater Biol Appl; 2013 Mar; 33(2):984-8. PubMed ID: 25427515 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]