These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 21476687)

  • 1. A theoretical comparison of attenuation measurement techniques from backscattered ultrasound echoes.
    Labyed Y; Bigelow TA
    J Acoust Soc Am; 2011 Apr; 129(4):2316-24. PubMed ID: 21476687
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the spectral fit algorithm as functions of frequency range and deltakaeff.
    Bigelow TA; O'Brien WD
    IEEE Trans Ultrason Ferroelectr Freq Control; 2005 Nov; 52(11):2003-10. PubMed ID: 16422412
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of local attenuation approximations when estimating correlation length from backscattered ultrasound echoes.
    Bigelow TA; O'Brien WD
    J Acoust Soc Am; 2006 Jul; 120(1):546-53. PubMed ID: 16875251
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Defining optimal axial and lateral resolution for estimating scatterer properties from volumes using ultrasound backscatter.
    Oelze ML; O'Brien WD
    J Acoust Soc Am; 2004 Jun; 115(6):3226-34. PubMed ID: 15237847
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Trade-offs in data acquisition and processing parameters for backscatter and scatterer size estimations.
    Liu W; Zagzebski JA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010; 57(2):340-52. PubMed ID: 20178900
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved scatterer property estimates from ultrasound backscatter using gate-edge correction and a pseudo-Welch technique.
    Ghoshal G; Oelze ML
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Dec; 57(12):2828-32. PubMed ID: 21156378
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hybrid spectral domain method for attenuation slope estimation.
    Kim H; Varghese T
    Ultrasound Med Biol; 2008 Nov; 34(11):1808-19. PubMed ID: 18621468
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optimization of the algorithms for estimating the ultrasonic attenuation along the propagation path.
    Labyed Y; Bigelow TA
    Ultrasonics; 2012 Aug; 52(6):720-9. PubMed ID: 22424697
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Estimation of total attenuation and scatterer size from backscattered ultrasound waveforms.
    Bigelow TA; Oelze ML; O'Brien WD
    J Acoust Soc Am; 2005 Mar; 117(3 Pt 1):1431-9. PubMed ID: 15807030
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultrasound attenuation estimation using backscattered echoes from multiple sources.
    Bigelow TA
    J Acoust Soc Am; 2008 Aug; 124(2):1367-73. PubMed ID: 18681622
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Estimating the total ultrasound attenuation along the propagation path by using a reference phantom.
    Labyed Y; Bigelow TA
    J Acoust Soc Am; 2010 Nov; 128(5):3232-8. PubMed ID: 21110618
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Estimation of scatterer size from backscattered ultrasound: a simulation study.
    Romijn RL; Thijssen JM; van Beuningen GJ
    IEEE Trans Ultrason Ferroelectr Freq Control; 1989; 36(6):593-606. PubMed ID: 18290239
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the impact of backscatter intensity variations on ultrasound attenuation estimation.
    Omari EA; Varghese T; Madsen EL; Frank G
    Med Phys; 2013 Aug; 40(8):082904. PubMed ID: 23927359
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lower Bound on Estimation Variance of the Ultrasonic Attenuation Coefficient Using the Spectral-Difference Reference-phantom Method.
    Samimi K; Varghese T
    Ultrason Imaging; 2017 May; 39(3):151-171. PubMed ID: 28425388
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Signal to noise ratio comparisons for ultrasound attenuation slope estimation algorithms.
    Omari EA; Varghese T
    Med Phys; 2014 Mar; 41(3):032902. PubMed ID: 24593741
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Estimating the total ultrasound attenuation along the propagation path by applying multiple filters to backscattered echoes from a single spherically focused source.
    Bigelow T
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Apr; 57(4):900-7. PubMed ID: 20378452
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved scatterer property estimates from ultrasound backscatter for small gate lengths using a gate-edge correction factor.
    Oelze ML; O'Brien WD
    J Acoust Soc Am; 2004 Nov; 116(5):3212-23. PubMed ID: 15603167
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Signal processing strategies that improve performance and understanding of the quantitative ultrasound SPECTRAL FIT algorithm.
    Bigelow TA; O'Brien WD
    J Acoust Soc Am; 2005 Sep; 118(3 Pt 1):1808-19. PubMed ID: 16240839
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Attenuation estimation by repeatedly solving the forward scattering problem.
    Ilyina N; Hermans J; Verboven E; Van Den Abeele K; D'Agostino E; D'hooge J
    Ultrasonics; 2018 Mar; 84():201-209. PubMed ID: 29156300
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Estimation of Tissue Attenuation from Ultrasonic B-Mode Images-Spectral-Log-Difference and Method-of-Moments Algorithms Compared.
    Brandner DM; Cai X; Foiret J; Ferrara KW; Zagar BG
    Sensors (Basel); 2021 Apr; 21(7):. PubMed ID: 33916496
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.