BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 21480652)

  • 21. Mathematical Analysis of Reaction-Diffusion Equations Modeling the Michaelis-Menten Kinetics in a Micro-Disk Biosensor.
    Khan NA; Alshammari FS; Romero CAT; Sulaiman M; Laouini G
    Molecules; 2021 Dec; 26(23):. PubMed ID: 34885892
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A new enzymatic serum creatinine measurement based on an endogenous creatine-eliminating system.
    Suzuki M; Yoshida M
    Clin Chim Acta; 1984 Nov; 143(2):147-55. PubMed ID: 6509773
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Optical biosensor based on hollow integrated waveguides.
    Cadarso VJ; Fernández-Sánchez C; Llobera A; Darder M; Domínguez C
    Anal Chem; 2008 May; 80(9):3498-501. PubMed ID: 18393473
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Theory and simulation of diffusion-controlled Michaelis-Menten kinetics for a static enzyme in solution.
    Park S; Agmon N
    J Phys Chem B; 2008 May; 112(19):5977-87. PubMed ID: 18220382
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The influence of external factors on the operational stability of the biosensor response.
    Stikoniene O; Ivanauskas F; Laurinavicius V
    Talanta; 2010 Jun; 81(4-5):1245-9. PubMed ID: 20441891
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An enzyme-chromogenic surface plasmon resonance biosensor probe for hydrogen peroxide determination using a modified Trinder's reagent.
    Nakamura H; Mogi Y; Akimoto T; Naemura K; Kato T; Yano K; Karube I
    Biosens Bioelectron; 2008 Nov; 24(3):455-60. PubMed ID: 18550356
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Analysis of mathematical modelling on potentiometric biosensors.
    Mehala N; Rajendran L
    ISRN Biochem; 2014; 2014():582675. PubMed ID: 25969765
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Amperometric biosensor for hydrogen peroxide based on coimmobilized horseradish peroxidase and methylene green in ormosils matrix with multiwalled carbon nanotubes.
    Upadhyay AK; Ting TW; Chen SM
    Talanta; 2009 Jun; 79(1):38-45. PubMed ID: 19376341
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Self-Powered Biosensor for Specifically Detecting Creatinine in Real Time Based on the Piezo-Enzymatic-Reaction Effect of Enzyme-Modified ZnO Nanowires.
    Wang M; Zi G; Liu J; Song Y; Zhao X; Wang Q; Zhao T
    Biosensors (Basel); 2021 Sep; 11(9):. PubMed ID: 34562932
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Numerical Modeling and Investigation of Amperometric Biosensors with Perforated Membranes.
    Hashem Zadeh SM; Heidarshenas M; Ghalambaz M; Noghrehabadi A; Saffari Pour M
    Sensors (Basel); 2020 May; 20(10):. PubMed ID: 32455593
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Solutions of the coupled reaction and diffusion equations within polymer-modified ultramicroelectrodes.
    Shanmugarajan A; Alwarappan S; Lakshmanan R; Kumar A
    J Phys Chem A; 2010 Jul; 114(26):7030-7. PubMed ID: 20536204
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Polypyrrole-glucose oxidase biosensor. Effect of enzyme encapsulation in multilamellar vesicles on analytical properties.
    Olea D; Viratelle O; Faure C
    Biosens Bioelectron; 2008 Jan; 23(6):788-94. PubMed ID: 17931850
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ferrocene branched chitosan for the construction of a reagentless amperometric hydrogen peroxide biosensor.
    Garcia A; Peniche-Covas C; Chico B; Simpson BK; Villalonga R
    Macromol Biosci; 2007 Apr; 7(4):435-9. PubMed ID: 17429804
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Mathematical simulation of an enzyme-based glucose sensor with pO2-basic sensor.
    Lemke K
    Biomed Biochim Acta; 1989; 48(11-12):867-77. PubMed ID: 2636831
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A nano-integrated microfluidic biochip for enzyme-based point-of-care detection of creatinine.
    Li J; Li Z; Dou Y; Su J; Shi J; Zhou Y; Wang L; Song S; Fan C
    Chem Commun (Camb); 2021 May; 57(38):4726-4729. PubMed ID: 33977964
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A microband lactate biosensor fabricated using a water-based screen-printed carbon ink.
    Rawson FJ; Purcell WM; Xu J; Pemberton RM; Fielden PR; Biddle N; Hart JP
    Talanta; 2009 Jan; 77(3):1149-54. PubMed ID: 19064104
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Consecutive hydrolysis of creatinine using creatininase and creatinase encapsulated in Saccharomyces cerevisiae spores.
    Kong J; Li Z; Zhang H; Gao XD; Nakanishi H
    Biotechnol Lett; 2017 Feb; 39(2):261-267. PubMed ID: 27734207
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Part-2: Analytical Expressions of Concentrations of Glucose, Oxygen, and Gluconic Acid in a Composite Membrane for Closed-Loop Insulin Delivery for the Non-steady State Conditions.
    Mehala N; Rajendran L; Meena V
    J Membr Biol; 2017 Feb; 250(1):89-101. PubMed ID: 27904934
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Creatinine hydrolase and creatine amidinohydrolase. I. Presence in cell-free extractions of Arthrobacter ureafaciens.
    Kaplan A; Naugler D
    Mol Cell Biochem; 1974 Mar; 3(1):9-15. PubMed ID: 4826702
    [No Abstract]   [Full Text] [Related]  

  • 40. Wavelet-Based Analytical Algorithm for Solving Steady-State Concentration in Immobilized Glucose Isomerase of Packed-Bed Reactor Model.
    Selvi MS; Hariharan G
    J Membr Biol; 2016 Aug; 249(4):559-68. PubMed ID: 27161606
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.