These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
486 related articles for article (PubMed ID: 21483877)
1. Evaluation of the effect of retightening and mechanical cycling on preload maintenance of retention screws. Delben JA; Gomes EA; Barão VA; Assunção WG Int J Oral Maxillofac Implants; 2011; 26(2):251-6. PubMed ID: 21483877 [TBL] [Abstract][Full Text] [Related]
2. Influence of abutment type and esthetic veneering on preload maintenance of abutment screw of implant-supported crowns. Delben JA; Barão VA; Dos Santos PH; Assunção WG J Prosthodont; 2014 Feb; 23(2):134-9. PubMed ID: 23725369 [TBL] [Abstract][Full Text] [Related]
3. The effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses. Assunção WG; Jorge JR; Dos Santos PH; Barão VA; Gomes EA; Delben JA J Prosthodont; 2011 Oct; 20(7):523-7. PubMed ID: 21895835 [TBL] [Abstract][Full Text] [Related]
4. In vitro study of the influence of the type of connection on the fracture load of zirconia abutments with internal and external implant-abutment connections. Sailer I; Sailer T; Stawarczyk B; Jung RE; Hämmerle CH Int J Oral Maxillofac Implants; 2009; 24(5):850-8. PubMed ID: 19865625 [TBL] [Abstract][Full Text] [Related]
5. Zirconia-implant-supported all-ceramic crowns withstand long-term load: a pilot investigation. Kohal RJ; Klaus G; Strub JR Clin Oral Implants Res; 2006 Oct; 17(5):565-71. PubMed ID: 16958698 [TBL] [Abstract][Full Text] [Related]
6. Implant abutment screw rotations and preloads for four different screw materials and surfaces. Martin WC; Woody RD; Miller BH; Miller AW J Prosthet Dent; 2001 Jul; 86(1):24-32. PubMed ID: 11458261 [TBL] [Abstract][Full Text] [Related]
7. Load fatigue performance of implant-ceramic abutment combinations. Nguyen HQ; Tan KB; Nicholls JI Int J Oral Maxillofac Implants; 2009; 24(4):636-46. PubMed ID: 19885403 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of torque maintenance of abutment and cylinder screws with Morse taper implants. Ferreira MB; Delben JA; Barão VA; Faverani LP; Dos Santos PH; Assunção WG J Craniofac Surg; 2012 Nov; 23(6):e631-4. PubMed ID: 23172504 [TBL] [Abstract][Full Text] [Related]
9. The effect of repeated torque in small diameter implants with machined and premachined abutments. Saboury A; Neshandar Asli H; Vaziri S Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e224-30. PubMed ID: 22376004 [TBL] [Abstract][Full Text] [Related]
10. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design. Kim SG; Park JU; Jeong JH; Bae C; Bae TS; Chee W Int J Oral Maxillofac Implants; 2009; 24(6):1061-7. PubMed ID: 20162110 [TBL] [Abstract][Full Text] [Related]
11. The role of implant/abutment system on torque maintenance of retention screws and vertical misfit of implant-supported crowns before and after mechanical cycling. Jorge JR; Barao VA; Delben JA; Assuncao WG Int J Oral Maxillofac Implants; 2013; 28(2):415-22. PubMed ID: 23527343 [TBL] [Abstract][Full Text] [Related]
12. Examination of the implant-abutment interface after fatigue testing. Cibirka RM; Nelson SK; Lang BR; Rueggeberg FA J Prosthet Dent; 2001 Mar; 85(3):268-75. PubMed ID: 11264934 [TBL] [Abstract][Full Text] [Related]
13. Zirconium dioxide based dental restorations. Studies on clinical performance and fracture behaviour. Larsson C Swed Dent J Suppl; 2011; (213):9-84. PubMed ID: 21919311 [TBL] [Abstract][Full Text] [Related]
14. Fatigue resistance and failure mode of CAD/CAM composite resin implant abutments restored with type III composite resin and porcelain veneers. Magne P; Oderich E; Boff LL; Cardoso AC; Belser UC Clin Oral Implants Res; 2011 Nov; 22(11):1275-81. PubMed ID: 21985284 [TBL] [Abstract][Full Text] [Related]
15. Wave analysis of implant screw loosening using an air cylindrical cyclic loading device. Lee J; Kim YS; Kim CW; Han JS J Prosthet Dent; 2002 Oct; 88(4):402-8. PubMed ID: 12447217 [TBL] [Abstract][Full Text] [Related]
16. Preload evaluation of different screws in external hexagon joint. Assunção WG; Delben JA; Tabata LF; Barão VA; Gomes EA; Garcia IR Implant Dent; 2012 Feb; 21(1):46-50. PubMed ID: 22228458 [TBL] [Abstract][Full Text] [Related]
17. The effect of framework design on fracture resistance of metal-ceramic implant-supported single crowns. de Oliveira JL; Martins LM; Sanada J; de Oliveira PC; do Valle AL Int J Prosthodont; 2010; 23(4):350-2. PubMed ID: 20617225 [TBL] [Abstract][Full Text] [Related]
18. Screw joint stability after the application of retorque in implant-supported dentures under simulated masticatory conditions. Farina AP; Spazzin AO; Consani RL; Mesquita MF J Prosthet Dent; 2014 Jun; 111(6):499-504. PubMed ID: 24423456 [TBL] [Abstract][Full Text] [Related]