These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

189 related articles for article (PubMed ID: 21487576)

  • 21. Reservoir-based dielectrophoresis for microfluidic particle separation by charge.
    Patel S; Qian S; Xuan X
    Electrophoresis; 2013 Apr; 34(7):961-8. PubMed ID: 23161644
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A continuous DC-insulator dielectrophoretic sorter of microparticles.
    Srivastava SK; Baylon-Cardiel JL; Lapizco-Encinas BH; Minerick AR
    J Chromatogr A; 2011 Apr; 1218(13):1780-9. PubMed ID: 21338990
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Continuous separation of colloidal particles using dielectrophoresis.
    Yunus NA; Nili H; Green NG
    Electrophoresis; 2013 Apr; 34(7):969-78. PubMed ID: 23436439
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Combined dielectrophoretic and impedance system for on-chip controlled bacteria concentration: Application to Escherichia coli.
    Del Moral-Zamora B; Punter-Villagrassa J; Oliva-Brañas AM; Álvarez-Azpeitia JM; Colomer-Farrarons J; Samitier J; Homs-Corbera A; Miribel-Català PL
    Electrophoresis; 2015 May; 36(9-10):1130-41. PubMed ID: 25752513
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Microfabrication technologies in dielectrophoresis applications--a review.
    Martinez-Duarte R
    Electrophoresis; 2012 Nov; 33(21):3110-32. PubMed ID: 22941778
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Joule heating effects on particle immobilization in insulator-based dielectrophoretic devices.
    Gallo-Villanueva RC; Sano MB; Lapizco-Encinas BH; Davalos RV
    Electrophoresis; 2014 Feb; 35(2-3):352-61. PubMed ID: 24002905
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Particle trapping in high-conductivity media with electrothermally enhanced negative dielectrophoresis.
    Park S; Koklu M; Beskok A
    Anal Chem; 2009 Mar; 81(6):2303-10. PubMed ID: 19215119
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Resonant dielectrophoresis and electrohydrodynamics for high-sensitivity impedance detection of whole-cell bacteria.
    Couniot N; Francis LA; Flandre D
    Lab Chip; 2015 Aug; 15(15):3183-91. PubMed ID: 26120099
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Electrokinetic instability effects in microchannels with and without nanofilm coatings.
    Fu LM; Hong TF; Wen CY; Tsai CH; Lin CH
    Electrophoresis; 2008 Dec; 29(24):4871-9. PubMed ID: 19130549
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Separation of mixtures of particles in a multipart microdevice employing insulator-based dielectrophoresis.
    Gallo-Villanueva RC; Pérez-González VH; Davalos RV; Lapizco-Encinas BH
    Electrophoresis; 2011 Sep; 32(18):2456-65. PubMed ID: 21874656
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A novel approach to dielectrophoresis using carbon electrodes.
    Martinez-Duarte R; Renaud P; Madou MJ
    Electrophoresis; 2011 Sep; 32(17):2385-92. PubMed ID: 21792991
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Label-free isolation and enrichment of cells through contactless dielectrophoresis.
    Elvington ES; Salmanzadeh A; Stremler MA; Davalos RV
    J Vis Exp; 2013 Sep; (79):. PubMed ID: 24056267
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Electrokinetic trapping using titania nanoporous membranes fabricated using sol-gel chemistry on microfluidic devices.
    Hoeman KW; Lange JJ; Roman GT; Higgins DA; Culbertson CT
    Electrophoresis; 2009 Sep; 30(18):3160-7. PubMed ID: 19722198
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Electrochemical attack and corrosion of platinum electrodes in dielectrophoretic diagnostic devices.
    Heineck DP; Sarno B; Kim S; Heller M
    Anal Bioanal Chem; 2020 Jun; 412(16):3871-3880. PubMed ID: 32277243
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Isolation of Langerhans islets by dielectrophoresis.
    Burgarella S; Merlo S; Figliuzzi M; Remuzzi A
    Electrophoresis; 2013 Apr; 34(7):1068-75. PubMed ID: 23161152
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Microfluidic devices for the isolation of circulating rare cells: a focus on affinity-based, dielectrophoresis, and hydrophoresis.
    Hyun KA; Jung HI
    Electrophoresis; 2013 Apr; 34(7):1028-41. PubMed ID: 23436295
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Continuous-flow label-free size fractionation of extracellular vesicles through electrothermal fluid rolls and dielectrophoresis synergistically integrated in a microfluidic device.
    Bu Y; Wang J; Ni S; Guo Y; Yobas L
    Lab Chip; 2023 May; 23(10):2421-2433. PubMed ID: 36951129
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Fabrication challenges and perspectives on the use of carbon-electrode dielectrophoresis in sample preparation.
    Martinez-Duarte R
    IET Nanobiotechnol; 2017 Mar; 11(2):127-133. PubMed ID: 28476994
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Development of a new contactless dielectrophoresis system for active particle manipulation using movable liquid electrodes.
    Gwon HR; Chang ST; Choi CK; Jung JY; Kim JM; Lee SH
    Electrophoresis; 2014 Jul; 35(14):2014-21. PubMed ID: 24737601
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Differentiation of Escherichia coli serotypes using DC gradient insulator dielectrophoresis.
    Jones PV; DeMichele AF; Kemp L; Hayes MA
    Anal Bioanal Chem; 2014 Jan; 406(1):183-92. PubMed ID: 24202194
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.