177 related articles for article (PubMed ID: 21500253)
41. Hyperpolarized
Wang J; Hesketh RL; Wright AJ; Brindle KM
NMR Biomed; 2018 Nov; 31(11):e4004. PubMed ID: 30198124
[TBL] [Abstract][Full Text] [Related]
42. Assessment of mouse liver [1-13C]pyruvate metabolism by dynamic hyperpolarized MRS.
Faarkrog Høyer K; Laustsen C; Ringgaard S; Qi H; Mariager CØ; Nielsen TS; Sundekilde UK; Treebak JT; Jessen N; Stødkilde-Jørgensen H
J Endocrinol; 2019 Sep; 242(3):251-260. PubMed ID: 31311004
[TBL] [Abstract][Full Text] [Related]
43. Application of double spin echo spiral chemical shift imaging to rapid metabolic mapping of hyperpolarized [1-¹³C]-pyruvate.
Josan S; Yen YF; Hurd R; Pfefferbaum A; Spielman D; Mayer D
J Magn Reson; 2011 Apr; 209(2):332-6. PubMed ID: 21316280
[TBL] [Abstract][Full Text] [Related]
44. Dynamic
Liu X; Cui D; Xu D; Bok R; Wang ZJ; Vigneron DB; Larson PEZ; Gordon JW
Magn Reson Med; 2024 Mar; 91(3):1030-1042. PubMed ID: 38013217
[TBL] [Abstract][Full Text] [Related]
45. Joint spatial-spectral reconstruction and k-t spirals for accelerated 2D spatial/1D spectral imaging of 13C dynamics.
Gordon JW; Niles DJ; Fain SB; Johnson KM
Magn Reson Med; 2014 Apr; 71(4):1435-45. PubMed ID: 23716402
[TBL] [Abstract][Full Text] [Related]
46. Effects of isoflurane anesthesia on hyperpolarized (13)C metabolic measurements in rat brain.
Josan S; Hurd R; Billingsley K; Senadheera L; Park JM; Yen YF; Pfefferbaum A; Spielman D; Mayer D
Magn Reson Med; 2013 Oct; 70(4):1117-24. PubMed ID: 23086864
[TBL] [Abstract][Full Text] [Related]
47. Accelerated 3D echo-planar imaging with compressed sensing for time-resolved hyperpolarized
Geraghty BJ; Lau JY; Chen AP; Cunningham CH
Magn Reson Med; 2017 Feb; 77(2):538-546. PubMed ID: 26806525
[TBL] [Abstract][Full Text] [Related]
48. Technique development of 3D dynamic CS-EPSI for hyperpolarized
Chen HY; Larson PEZ; Gordon JW; Bok RA; Ferrone M; van Criekinge M; Carvajal L; Cao P; Pauly JM; Kerr AB; Park I; Slater JB; Nelson SJ; Munster PN; Aggarwal R; Kurhanewicz J; Vigneron DB
Magn Reson Med; 2018 Nov; 80(5):2062-2072. PubMed ID: 29575178
[TBL] [Abstract][Full Text] [Related]
49. High resolution hyperpolarized
Lee H; Song JE; Shin J; Joe E; Joo CG; Choi YS; Song HT; Kim DH
Magn Reson Med; 2018 Aug; 80(2):703-710. PubMed ID: 29315780
[TBL] [Abstract][Full Text] [Related]
50. Simultaneous fMRI and metabolic MRS of hyperpolarized [1-
Hyppönen VA; Rosa J; Kettunen MI
NMR Biomed; 2024 May; 37(5):e5108. PubMed ID: 38273732
[TBL] [Abstract][Full Text] [Related]
51. Imaging considerations for in vivo 13C metabolic mapping using hyperpolarized 13C-pyruvate.
Yen YF; Kohler SJ; Chen AP; Tropp J; Bok R; Wolber J; Albers MJ; Gram KA; Zierhut ML; Park I; Zhang V; Hu S; Nelson SJ; Vigneron DB; Kurhanewicz J; Dirven HA; Hurd RE
Magn Reson Med; 2009 Jul; 62(1):1-10. PubMed ID: 19319902
[TBL] [Abstract][Full Text] [Related]
52. High-resolution hyperpolarized metabolic imaging of the rat heart using k-t PCA and k-t SPARSE.
Wespi P; Steinhauser J; Kwiatkowski G; Kozerke S
NMR Biomed; 2018 Feb; 31(2):. PubMed ID: 29244228
[No Abstract] [Full Text] [Related]
53. Multi-band frequency encoding method for metabolic imaging with hyperpolarized [1-(13)C]pyruvate.
von Morze C; Reed G; Shin P; Larson PE; Hu S; Bok R; Vigneron DB
J Magn Reson; 2011 Aug; 211(2):109-13. PubMed ID: 21596601
[TBL] [Abstract][Full Text] [Related]
54. Hyperpolarized [1-13C] pyruvate MR spectroscopy detect altered glycolysis in the brain of a cognitively impaired mouse model fed high-fat diet.
Choi YS; Kang S; Ko SY; Lee S; Kim JY; Lee H; Song JE; Kim DH; Kim E; Kim CH; Saksida L; Song HT; Lee JE
Mol Brain; 2018 Dec; 11(1):74. PubMed ID: 30563553
[TBL] [Abstract][Full Text] [Related]
55. A regional bolus tracking and real-time B
Tang S; Milshteyn E; Reed G; Gordon J; Bok R; Zhu X; Zhu Z; Vigneron DB; Larson PEZ
Magn Reson Med; 2019 Feb; 81(2):839-851. PubMed ID: 30277268
[TBL] [Abstract][Full Text] [Related]
56. Multi-channel metabolic imaging, with SENSE reconstruction, of hyperpolarized [1-(13)C] pyruvate in a live rat at 3.0 tesla on a clinical MR scanner.
Tropp J; Lupo JM; Chen A; Calderon P; McCune D; Grafendorfer T; Ozturk-Isik E; Larson PE; Hu S; Yen YF; Robb F; Bok R; Schulte R; Xu D; Hurd R; Vigneron D; Nelson S
J Magn Reson; 2011 Jan; 208(1):171-7. PubMed ID: 21130012
[TBL] [Abstract][Full Text] [Related]
57. Super-Resolution Hyperpolarized
Ma J; Park JM
Tomography; 2020 Dec; 6(4):343-355. PubMed ID: 33364424
[TBL] [Abstract][Full Text] [Related]
58. Chemical shift encoded imaging of hyperpolarized (13) C pyruvate.
Wiens CN; Friesen-Waldner LJ; Wade TP; Sinclair KJ; McKenzie CA
Magn Reson Med; 2015 Dec; 74(6):1682-9. PubMed ID: 25427313
[TBL] [Abstract][Full Text] [Related]
59. Fast dynamic 3D MR spectroscopic imaging with compressed sensing and multiband excitation pulses for hyperpolarized 13C studies.
Larson PE; Hu S; Lustig M; Kerr AB; Nelson SJ; Kurhanewicz J; Pauly JM; Vigneron DB
Magn Reson Med; 2011 Mar; 65(3):610-9. PubMed ID: 20939089
[TBL] [Abstract][Full Text] [Related]
60. Rapid multislice imaging of hyperpolarized 13C pyruvate and bicarbonate in the heart.
Lau AZ; Chen AP; Ghugre NR; Ramanan V; Lam WW; Connelly KA; Wright GA; Cunningham CH
Magn Reson Med; 2010 Nov; 64(5):1323-31. PubMed ID: 20574989
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]