613 related articles for article (PubMed ID: 21500259)
1. Reduction of implant RF heating through modification of transmit coil electric field.
Eryaman Y; Akin B; Atalar E
Magn Reson Med; 2011 May; 65(5):1305-13. PubMed ID: 21500259
[TBL] [Abstract][Full Text] [Related]
2. RF heating due to conductive wires during MRI depends on the phase distribution of the transmit field.
Yeung CJ; Susil RC; Atalar E
Magn Reson Med; 2002 Dec; 48(6):1096-8. PubMed ID: 12465125
[TBL] [Abstract][Full Text] [Related]
3. Effects of coil dimensions and field polarization on RF heating inside a head phantom.
Kangarlu A; Ibrahim TS; Shellock FG
Magn Reson Imaging; 2005 Jan; 23(1):53-60. PubMed ID: 15733788
[TBL] [Abstract][Full Text] [Related]
4. Reduction of the radiofrequency heating of metallic devices using a dual-drive birdcage coil.
Eryaman Y; Turk EA; Oto C; Algin O; Atalar E
Magn Reson Med; 2013 Mar; 69(3):845-52. PubMed ID: 22576183
[TBL] [Abstract][Full Text] [Related]
5. A comparative numerical study of rotating and stationary RF coils in terms of flip angle and specific absorption rate for 7 T MRI.
Trakic A; Jin J; Li MY; McClymont D; Weber E; Liu F; Crozier S
J Magn Reson; 2013 Nov; 236():70-82. PubMed ID: 24076497
[TBL] [Abstract][Full Text] [Related]
6. Investigation of Parallel Radiofrequency Transmission for the Reduction of Heating in Long Conductive Leads in 3 Tesla Magnetic Resonance Imaging.
McElcheran CE; Yang B; Anderson KJ; Golenstani-Rad L; Graham SJ
PLoS One; 2015; 10(8):e0134379. PubMed ID: 26237218
[TBL] [Abstract][Full Text] [Related]
7. B1 field, SAR, and SNR comparisons for birdcage, TEM, and microstrip coils at 7T.
Wang C; Shen GX
J Magn Reson Imaging; 2006 Aug; 24(2):439-43. PubMed ID: 16786582
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of RF heating due to various implants during MR procedures.
Muranaka H; Horiguchi T; Ueda Y; Tanki N
Magn Reson Med Sci; 2011; 10(1):11-9. PubMed ID: 21441723
[TBL] [Abstract][Full Text] [Related]
9. Parallel transmit excitation at 1.5 T based on the minimization of a driving function for device heating.
Gudino N; Sonmez M; Yao Z; Baig T; Nielles-Vallespin S; Faranesh AZ; Lederman RJ; Martens M; Balaban RS; Hansen MS; Griswold MA
Med Phys; 2015 Jan; 42(1):359-71. PubMed ID: 25563276
[TBL] [Abstract][Full Text] [Related]
10. MRI-induced heating of selected thin wire metallic implants-- laboratory and computational studies-- findings and new questions raised.
Bassen H; Kainz W; Mendoza G; Kellom T
Minim Invasive Ther Allied Technol; 2006; 15(2):76-84. PubMed ID: 16754190
[TBL] [Abstract][Full Text] [Related]
11. Numerical Simulations of Realistic Lead Trajectories and an Experimental Verification Support the Efficacy of Parallel Radiofrequency Transmission to Reduce Heating of Deep Brain Stimulation Implants during MRI.
McElcheran CE; Golestanirad L; Iacono MI; Wei PS; Yang B; Anderson KJT; Bonmassar G; Graham SJ
Sci Rep; 2019 Feb; 9(1):2124. PubMed ID: 30765724
[TBL] [Abstract][Full Text] [Related]
12. Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla.
Ibrahim TS; Mitchell C; Schmalbrock P; Lee R; Chakeres DW
Magn Reson Med; 2005 Sep; 54(3):683-90. PubMed ID: 16088934
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of RF heating on humerus implant in phantoms during 1.5T MR imaging and comparisons with electromagnetic simulation.
Muranaka H; Horiguchi T; Usui S; Ueda Y; Nakamura O; Ikeda F; Iwakura K; Nakaya G
Magn Reson Med Sci; 2006 Jul; 5(2):79-88. PubMed ID: 17008764
[TBL] [Abstract][Full Text] [Related]
14. An Asymmetric Birdcage Coil for Small-animal MR Imaging at 7T.
Kim KN; Han SD; Seo JH; Heo P; Yoo D; Im GH; Lee JH
Magn Reson Med Sci; 2017 Jul; 16(3):253-258. PubMed ID: 27725573
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of feasibility of 1.5 Tesla prostate MRI using body coil RF transmit in a patient with an implanted vagus nerve stimulator.
Favazza CP; Edmonson HA; Ma C; Shu Y; Felmlee JP; Watson RE; Gorny KR
Med Phys; 2017 Nov; 44(11):5749-5754. PubMed ID: 28880381
[TBL] [Abstract][Full Text] [Related]
16. Dependence of RF heating on SAR and implant position in a 1.5T MR system.
Muranaka H; Horiguchi T; Usui S; Ueda Y; Nakamura O; Ikeda F
Magn Reson Med Sci; 2007; 6(4):199-209. PubMed ID: 18239357
[TBL] [Abstract][Full Text] [Related]
17. Patient safety concept for multichannel transmit coils.
Seifert F; Wübbeler G; Junge S; Ittermann B; Rinneberg H
J Magn Reson Imaging; 2007 Nov; 26(5):1315-21. PubMed ID: 17969165
[TBL] [Abstract][Full Text] [Related]
18. Convex optimization of MRI exposure for mitigation of RF-heating from active medical implants.
Córcoles J; Zastrow E; Kuster N
Phys Med Biol; 2015 Sep; 60(18):7293-308. PubMed ID: 26350025
[TBL] [Abstract][Full Text] [Related]
19. A PIN diode controlled dual-tuned MRI RF coil and phased array for multi nuclear imaging.
Ha S; Hamamura MJ; Nalcioglu O; Muftuler LT
Phys Med Biol; 2010 May; 55(9):2589-600. PubMed ID: 20393229
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of MRI RF electromagnetic field induced heating near leads of cochlear implants.
Zeng Q; Wang Q; Zheng J; Kainz W; Chen J
Phys Med Biol; 2018 Jul; 63(13):135020. PubMed ID: 29893289
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]