149 related articles for article (PubMed ID: 21500820)
1. Highly sensitive potentiometric strip test for detecting high charge density impurities in heparin.
Kang Y; Gwon K; Shin JH; Nam H; Meyerhoff ME; Cha GS
Anal Chem; 2011 May; 83(10):3957-62. PubMed ID: 21500820
[TBL] [Abstract][Full Text] [Related]
2. Detection of high-charge density polyanion contaminants in biomedical heparin preparations using potentiometric polyanion sensors.
Wang L; Buchanan S; Meyerhoff ME
Anal Chem; 2008 Dec; 80(24):9845-7. PubMed ID: 19007240
[TBL] [Abstract][Full Text] [Related]
3. Reversible Electrochemical Sensor for Detection of High-Charge Density Polyanion Contaminants in Heparin.
Lester J; Chandler T; Gemene KL
Anal Chem; 2015 Nov; 87(22):11537-43. PubMed ID: 26485655
[TBL] [Abstract][Full Text] [Related]
4. Synthesis and detection of N-sulfonated oversulfated chondroitin sulfate in marketplace heparin.
Mans DJ; Ye H; Dunn JD; Kolinski RE; Long DS; Phatak NL; Ghasriani H; Buhse LF; Kauffman JF; Keire DA
Anal Biochem; 2015 Dec; 490():52-4. PubMed ID: 26278168
[TBL] [Abstract][Full Text] [Related]
5. Analysis of crude heparin by (1)H NMR, capillary electrophoresis, and strong-anion-exchange-HPLC for contamination by over sulfated chondroitin sulfate.
Keire DA; Trehy ML; Reepmeyer JC; Kolinski RE; Ye W; Dunn J; Westenberger BJ; Buhse LF
J Pharm Biomed Anal; 2010 Mar; 51(4):921-6. PubMed ID: 19959313
[TBL] [Abstract][Full Text] [Related]
6. Potentiometric sensor for heparin polyion: transient behavior and response mechanism.
Langmaier J; Samcova E; Samec Z
Anal Chem; 2007 Apr; 79(7):2892-900. PubMed ID: 17315978
[TBL] [Abstract][Full Text] [Related]
7. Sensitive detection of oversulfated chondroitin sulfate in heparin sodium or crude heparin with a colorimetric microplate based assay.
Sommers CD; Mans DJ; Mecker LC; Keire DA
Anal Chem; 2011 May; 83(9):3422-30. PubMed ID: 21449571
[TBL] [Abstract][Full Text] [Related]
8. Heparin identification test and purity test for OSCS in heparin sodium and heparin calcium by weak anion-exchange high-performance liquid chromatography.
Hashii N; Kawasaki N; Itoh S; Qin Y; Fujita N; Hattori T; Miyata K; Bando A; Sekimoto Y; Hama T; Kashimura M; Tatsumi M; Mabuchi K; Namekawa H; Sakai T; Hirose M; Dobashi S; Shimahashi H; Koyama S; Herr SO; Kawai K; Yoden H; Yamaguchi T
Biologicals; 2010 Sep; 38(5):539-43. PubMed ID: 20452241
[TBL] [Abstract][Full Text] [Related]
9. Analysis of heparin sodium by SAX/HPLC for contaminants and impurities.
Trehy ML; Reepmeyer JC; Kolinski RE; Westenberger BJ; Buhse LF
J Pharm Biomed Anal; 2009 Apr; 49(3):670-3. PubMed ID: 19167854
[TBL] [Abstract][Full Text] [Related]
10. Quantitative capillary electrophoresis determination of oversulfated chondroitin sulfate as a contaminant in heparin preparations.
Volpi N; Maccari F; Linhardt RJ
Anal Biochem; 2009 May; 388(1):140-5. PubMed ID: 19232311
[TBL] [Abstract][Full Text] [Related]
11. Identification of heparin samples that contain impurities or contaminants by chemometric pattern recognition analysis of proton NMR spectral data.
Zang Q; Keire DA; Buhse LF; Wood RD; Mital DP; Haque S; Srinivasan S; Moore CM; Nasr M; Al-Hakim A; Trehy ML; Welsh WJ
Anal Bioanal Chem; 2011 Aug; 401(3):939-55. PubMed ID: 21678118
[TBL] [Abstract][Full Text] [Related]
12. Molecular Beacon-Based Fluorescent Assay for Specific Detection of Oversulfated Chondroitin Sulfate Contaminants in Heparin without Enzyme Treatment.
Lee CY; Tseng WL
Anal Chem; 2015; 87(10):5031-5. PubMed ID: 25927411
[TBL] [Abstract][Full Text] [Related]
13. Simple fluorescence assay for quantification of OSCS in heparin.
Lühn S; Schiemann S; Alban S
Anal Bioanal Chem; 2011 Jan; 399(2):673-80. PubMed ID: 20552175
[TBL] [Abstract][Full Text] [Related]
14. Combining (1)H NMR spectroscopy and chemometrics to identify heparin samples that may possess dermatan sulfate (DS) impurities or oversulfated chondroitin sulfate (OSCS) contaminants.
Zang Q; Keire DA; Wood RD; Buhse LF; Moore CM; Nasr M; Al-Hakim A; Trehy ML; Welsh WJ
J Pharm Biomed Anal; 2011 Apr; 54(5):1020-9. PubMed ID: 21215547
[TBL] [Abstract][Full Text] [Related]
15. Identification of a simple and sensitive microplate method for the detection of oversulfated chondroitin sulfate in heparin products.
Bairstow S; McKee J; Nordhaus M; Johnson R
Anal Biochem; 2009 May; 388(2):317-21. PubMed ID: 19289093
[TBL] [Abstract][Full Text] [Related]
16. A nanosensor for ultrasensitive detection of oversulfated chondroitin sulfate contaminant in heparin.
Kalita M; Balivada S; Swarup VP; Mencio C; Raman K; Desai UR; Troyer D; Kuberan B
J Am Chem Soc; 2014 Jan; 136(2):554-7. PubMed ID: 24127748
[TBL] [Abstract][Full Text] [Related]
17. Quantitative Determination of High Charge Density Polyanion Contaminants in Biomedical Heparin Preparations Using Potentiometric Polyanion Sensors.
Wang L; Meyerhoff ME
Electroanalysis; 2010 Jan; 22(1):26-30. PubMed ID: 21151739
[TBL] [Abstract][Full Text] [Related]
18. Determination of oversulfated chondroitin sulfate and dermatan sulfate impurities in heparin by capillary electrophoresis.
Somsen GW; Tak YH; Toraño JS; Jongen PM; de Jong GJ
J Chromatogr A; 2009 May; 1216(18):4107-12. PubMed ID: 19272607
[TBL] [Abstract][Full Text] [Related]
19. Combination of a two-step fluorescence assay and a two-step anti-Factor Xa assay for detection of heparin falsifications and protein in heparins.
Alban S; Lühn S; Schiemann S
Anal Bioanal Chem; 2011 Jan; 399(2):681-90. PubMed ID: 20953779
[TBL] [Abstract][Full Text] [Related]
20. The use of SAX-HPLC-CD as a heparin screening strategy.
Chmielewski AJ; Stanley FE; Stalcup AM
J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Sep; 879(25):2619-23. PubMed ID: 21831728
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]