1. Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy. Robertson D; Polf JC; Peterson SW; Gillin MT; Beddar S Phys Med Biol; 2011 May; 56(10):3047-59. PubMed ID: 21508442 [TBL] [Abstract][Full Text] [Related]
2. Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy. Peterson SW; Robertson D; Polf J Phys Med Biol; 2010 Nov; 55(22):6841-56. PubMed ID: 21048295 [TBL] [Abstract][Full Text] [Related]
4. Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification. Polf JC; Avery S; Mackin DS; Beddar S Phys Med Biol; 2015 Sep; 60(18):7085-99. PubMed ID: 26317610 [TBL] [Abstract][Full Text] [Related]
5. CeBr Dal Bello R; Magalhaes Martins P; Seco J Med Phys; 2018 Apr; 45(4):1622-1630. PubMed ID: 29411400 [TBL] [Abstract][Full Text] [Related]
6. The effects of Doppler broadening and detector resolution on the performance of three-stage Compton cameras. Mackin D; Polf J; Peterson S; Beddar S Med Phys; 2013 Jan; 40(1):012402. PubMed ID: 23298111 [TBL] [Abstract][Full Text] [Related]
7. Optimization of the Compton camera for measuring prompt gamma rays in boron neutron capture therapy. Gong CH; Tang XB; Shu DY; Yu HY; Geng CR Appl Radiat Isot; 2017 Jun; 124():62-67. PubMed ID: 28342380 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy. Mackin D; Peterson S; Beddar S; Polf J Phys Med Biol; 2012 Jun; 57(11):3537-53. PubMed ID: 22588144 [TBL] [Abstract][Full Text] [Related]
9. Detecting prompt gamma emission during proton therapy: the effects of detector size and distance from the patient. Polf JC; Mackin D; Lee E; Avery S; Beddar S Phys Med Biol; 2014 May; 59(9):2325-40. PubMed ID: 24732052 [TBL] [Abstract][Full Text] [Related]
10. Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters. Cambraia Lopes P; Clementel E; Crespo P; Henrotin S; Huizenga J; Janssens G; Parodi K; Prieels D; Roellinghoff F; Smeets J; Stichelbaut F; Schaart DR Phys Med Biol; 2015 Aug; 60(15):6063-85. PubMed ID: 26216269 [TBL] [Abstract][Full Text] [Related]
11. Noise evaluation of Compton camera imaging for proton therapy. Ortega PG; Torres-Espallardo I; Cerutti F; Ferrari A; Gillam JE; Lacasta C; Llosá G; Oliver JF; Sala PR; Solevi P; Rafecas M Phys Med Biol; 2015 Mar; 60(5):1845-63. PubMed ID: 25658644 [TBL] [Abstract][Full Text] [Related]
12. Machine learning approach for proton range verification using real-time prompt gamma imaging with Compton cameras: addressing the total deposited energy information gap. Kazemi Kozani M Phys Med Biol; 2024 Mar; 69(7):. PubMed ID: 38417182 [No Abstract] [Full Text] [Related]
13. NaI gamma camera performance for high energies: Effects of crystal thickness, photomultiplier tube geometry and light guide thickness. Cosmi V; Wang B; Goorden MC; Beekman FJ Med Phys; 2024 Jul; 51(7):4696-4708. PubMed ID: 38569052 [TBL] [Abstract][Full Text] [Related]
14. Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera. Roellinghoff F; Benilov A; Dauvergne D; Dedes G; Freud N; Janssens G; Krimmer J; Létang JM; Pinto M; Prieels D; Ray C; Smeets J; Stichelbaut F; Testa E Phys Med Biol; 2014 Mar; 59(5):1327-38. PubMed ID: 24556873 [TBL] [Abstract][Full Text] [Related]
15. Energy- and time-resolved detection of prompt gamma-rays for proton range verification. Verburg JM; Riley K; Bortfeld T; Seco J Phys Med Biol; 2013 Oct; 58(20):L37-49. PubMed ID: 24077338 [TBL] [Abstract][Full Text] [Related]
16. Performance of MACACO Compton telescope for ion-beam therapy monitoring: first test with proton beams. Solevi P; Muñoz E; Solaz C; Trovato M; Dendooven P; Gillam JE; Lacasta C; Oliver JF; Rafecas M; Torres-Espallardo I; Llosá G Phys Med Biol; 2016 Jul; 61(14):5149-65. PubMed ID: 27352107 [TBL] [Abstract][Full Text] [Related]
17. Use of a LYSO-based Compton camera for prompt gamma range verification in proton therapy. Jan ML; Hsiao IT; Huang HM Med Phys; 2017 Dec; 44(12):6261-6269. PubMed ID: 29031024 [TBL] [Abstract][Full Text] [Related]
18. Beta-ray imaging system with γ-ray coincidence for multiple-tracer imaging. Fukuchi T; Yamamoto S; Kataoka J; Kamada K; Yoshikawa A; Watanabe Y; Enomoto S Med Phys; 2020 Feb; 47(2):587-596. PubMed ID: 31800969 [TBL] [Abstract][Full Text] [Related]
19. Influence of sub-nanosecond time of flight resolution for online range verification in proton therapy using the line-cone reconstruction in Compton imaging. Livingstone J; Dauvergne D; Etxebeste A; Fontana M; Gallin-Martel ML; Huisman B; Létang JM; Marcatili S; Sarrut D; Testa É Phys Med Biol; 2021 Jun; 66(12):. PubMed ID: 34020434 [TBL] [Abstract][Full Text] [Related]
20. Distal edge determination precision for a multi-slat prompt-gamma camera: A comprehensive simulation and optimization of the detection system. Morozov A; Simões H; Crespo P Phys Med; 2021 Apr; 84():85-100. PubMed ID: 33882445 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]