430 related articles for article (PubMed ID: 21520826)
1. The neutron dose equivalent evaluation and shielding at the maze entrance of a Varian Clinac 23EX treatment room.
Wang X; Esquivel C; Nes E; Shi C; Papanikolaou N; Charlton M
Med Phys; 2011 Mar; 38(3):1141-9. PubMed ID: 21520826
[TBL] [Abstract][Full Text] [Related]
2. New empirical formula for neutron dose level at the maze entrance of 15 MV medical accelerator facilities.
Kim HS; Jang KW; Park YH; Kwon JW; Choi HS; Lee JK; Kim JK
Med Phys; 2009 May; 36(5):1512-20. PubMed ID: 19544767
[TBL] [Abstract][Full Text] [Related]
3. Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy.
Wang X; Charlton MA; Esquivel C; Eng TY; Li Y; Papanikolaou N
Med Phys; 2013 Sep; 40(9):093901. PubMed ID: 24007186
[TBL] [Abstract][Full Text] [Related]
4. On the tenth value distance of the photon field along the maze of high-energy linear accelerator vaults.
Han Z; Chin LM
J Appl Clin Med Phys; 2018 Mar; 19(2):311-316. PubMed ID: 29374424
[TBL] [Abstract][Full Text] [Related]
5. SU-E-T-267: Construction and Evaluation of a Neutron Wall to Shield a 15 MV Linac in a Low-Energy Vault.
Speiser M; Hager F; Foster R; Solberg T
Med Phys; 2012 Jun; 39(6Part14):3764-3765. PubMed ID: 28517270
[TBL] [Abstract][Full Text] [Related]
6. Effectiveness of customised neutron shielding in the maze of radiotherapy accelerators.
Waller EJ; Jamieson TJ; Cole D; Cousins T; Jammal RB
Radiat Prot Dosimetry; 2003; 107(4):233-8. PubMed ID: 14756179
[TBL] [Abstract][Full Text] [Related]
7. The measurement of photoneutron dose in the vicinity of clinical linear accelerators.
Rivera JC; Falcão RC; Dealmeida CE
Radiat Prot Dosimetry; 2008; 130(4):403-9. PubMed ID: 18375468
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of neutron dose in the maze of medical electron accelerators.
Carinou E; Kamenopoulou V; Stamatelatos IE
Med Phys; 1999 Dec; 26(12):2520-5. PubMed ID: 10619233
[TBL] [Abstract][Full Text] [Related]
9. Neutron dose calculation at the maze entrance of medical linear accelerator rooms.
Falcão RC; Facure A; Silva AX
Radiat Prot Dosimetry; 2007; 123(3):283-7. PubMed ID: 17005540
[TBL] [Abstract][Full Text] [Related]
10. The effect of a paraffin screen on the neutron dose at the maze door of a 15 MV linear accelerator.
Krmar M; Nikolić D; Kuzmanović A; Kuzmanović Z; Ganezer K
Med Phys; 2013 Aug; 40(8):083902. PubMed ID: 23927362
[TBL] [Abstract][Full Text] [Related]
11. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
Chibani O; Ma CM
Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
[TBL] [Abstract][Full Text] [Related]
12. Photoneutrons and Gamma Capture Dose Rates at the Maze Entrance of Varian TrueBeam and Elekta Versa HD Medical Linear Accelerators.
Suliman II; Khouqeer GA; Mayhoub FH
Toxics; 2023 Jan; 11(1):. PubMed ID: 36668803
[TBL] [Abstract][Full Text] [Related]
13. Ambient neutron dose equivalent outside concrete vault rooms for 15 and 18 MV radiotherapy accelerators.
Martínez-Ovalle SA; Barquero R; Gómez-Ros JM; Lallena AM
Radiat Prot Dosimetry; 2012 Mar; 148(4):457-64. PubMed ID: 21750004
[TBL] [Abstract][Full Text] [Related]
14. Are neutrons responsible for the dose discrepancies between Monte Carlo calculations and measurements in the build-up region for a high-energy photon beam?
Ding GX; Duzenli C; Kalach NI
Phys Med Biol; 2002 Sep; 47(17):3251-61. PubMed ID: 12361221
[TBL] [Abstract][Full Text] [Related]
15. Neutron dose equivalent measured at the maze door with various openings for the jaws and MLC.
Krmar M; Baucal M; Bozic N; Jovancevic N; Ciraj-Bjelac O
Med Phys; 2012 Mar; 39(3):1278-81. PubMed ID: 22380359
[TBL] [Abstract][Full Text] [Related]
16. Neutron contamination of 10 MV X-rays: its relevance to treatment room door and maze design.
Rudd PJ; Prior D; Austin-Smith S
Br J Radiol; 2007 Jun; 80(954):469-75. PubMed ID: 17360932
[TBL] [Abstract][Full Text] [Related]
17. Shielding evaluation of a medical linear accelerator vault in preparation for installing a high-dose rate 252Cf remote afterloader.
Melhus CS; Rivard MJ; Kurkomelis J; Liddle CB; Massé FX
Radiat Prot Dosimetry; 2005; 113(4):428-37. PubMed ID: 15755770
[TBL] [Abstract][Full Text] [Related]
18. The effect of the flattening filter on photoneutron production at 10 MV in the Varian TrueBeam linear accelerator.
Montgomery L; Evans M; Liang L; Maglieri R; Kildea J
Med Phys; 2018 Oct; 45(10):4711-4719. PubMed ID: 30141186
[TBL] [Abstract][Full Text] [Related]
19. Neutron dosimetry in organs of an adult human phantom using linacs with multileaf collimator in radiotherapy treatments.
Martinez-Ovalle SA; Barquero R; Gomez-Ros JM; Lallena AM
Med Phys; 2012 May; 39(5):2854-66. PubMed ID: 22559658
[TBL] [Abstract][Full Text] [Related]
20. The evaluation of the neutron dose equivalent in the two-bend maze.
Tóth ÁÁ; Petrović B; Jovančević N; Krmar M; Rutonjski L; Čudić O
Phys Med; 2017 Apr; 36():119-125. PubMed ID: 28410680
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]