266 related articles for article (PubMed ID: 21520840)
1. Current status and future perspective of flattening filter free photon beams.
Georg D; Knöös T; McClean B
Med Phys; 2011 Mar; 38(3):1280-93. PubMed ID: 21520840
[TBL] [Abstract][Full Text] [Related]
2. Dosimetric characteristics of 6 and 10MV unflattened photon beams.
Kragl G; af Wetterstedt S; Knäusl B; Lind M; McCavana P; Knöös T; McClean B; Georg D
Radiother Oncol; 2009 Oct; 93(1):141-6. PubMed ID: 19592123
[TBL] [Abstract][Full Text] [Related]
3. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
Almberg SS; Frengen J; Lindmo T
Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
[TBL] [Abstract][Full Text] [Related]
4. Beam characteristics of energy-matched flattening filter free beams.
Paynter D; Weston SJ; Cosgrove VP; Evans JA; Thwaites DI
Med Phys; 2014 May; 41(5):052103. PubMed ID: 24784392
[TBL] [Abstract][Full Text] [Related]
5. Flattening filter free beams in SBRT and IMRT: dosimetric assessment of peripheral doses.
Kragl G; Baier F; Lutz S; Albrich D; Dalaryd M; Kroupa B; Wiezorek T; Knöös T; Georg D
Z Med Phys; 2011 May; 21(2):91-101. PubMed ID: 20888199
[TBL] [Abstract][Full Text] [Related]
6. Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy.
Fogliata A; Garcia R; Knoos T; Nicolini G; Clivio A; Vanetti E; Khamphan C; Cozzi L
Med Phys; 2012 Oct; 39(10):6455-64. PubMed ID: 23039680
[TBL] [Abstract][Full Text] [Related]
7. Flattening filter free in intensity-modulated radiotherapy (IMRT) - Theoretical modeling with delivery efficiency analysis.
Ma C; Chen M; Long T; Parsons D; Gu X; Jiang S; Hou Q; Lu W
Med Phys; 2019 Jan; 46(1):34-44. PubMed ID: 30371944
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of an aSi-EPID with flattening filter free beams: applicability to the GLAaS algorithm for portal dosimetry and first experience for pretreatment QA of RapidArc.
Nicolini G; Clivio A; Vanetti E; Krauss H; Fenoglietto P; Cozzi L; Fogliata A
Med Phys; 2013 Nov; 40(11):111719. PubMed ID: 24320427
[TBL] [Abstract][Full Text] [Related]
9. Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams.
Dalaryd M; Knöös T; Ceberg C
Med Phys; 2014 Nov; 41(11):111716. PubMed ID: 25370630
[TBL] [Abstract][Full Text] [Related]
10. Feasibility study of using flattening-filter-free photon beams to deliver conventional flat beams.
Potter NJ; Lebron S; Li JG; Liu C; Lu B
Med Dosim; 2019 Winter; 44(4):e25-e31. PubMed ID: 30630654
[TBL] [Abstract][Full Text] [Related]
11. Characteristics of flattening filter free beams at low monitor unit settings.
Akino Y; Ota S; Inoue S; Mizuno H; Sumida I; Yoshioka Y; Isohashi F; Ogawa K
Med Phys; 2013 Nov; 40(11):112101. PubMed ID: 24320454
[TBL] [Abstract][Full Text] [Related]
12. Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer.
Hrbacek J; Lang S; Graydon SN; Klöck S; Riesterer O
Med Phys; 2014 Mar; 41(3):031709. PubMed ID: 24593713
[TBL] [Abstract][Full Text] [Related]
13. Beam flatness modulation for a flattening filter free photon beam utilizing a novel direct leaf trajectory optimization model.
Potter NJ; Yan G; Liu H; Alahmad H; Kahler DL; Liu C; Li JG; Lu B
J Appl Clin Med Phys; 2020 Mar; 21(3):142-152. PubMed ID: 32176453
[TBL] [Abstract][Full Text] [Related]
14. A direction-selective flattening filter for clinical photon beams. Monte Carlo evaluation of a new concept.
Chofor N; Harder D; Willborn K; Rühmann A; Poppe B
Phys Med Biol; 2011 Jul; 56(14):4355-76. PubMed ID: 21709343
[TBL] [Abstract][Full Text] [Related]
15. Radiation therapy with unflattened photon beams: dosimetric accuracy of advanced dose calculation algorithms.
Kragl G; Albrich D; Georg D
Radiother Oncol; 2011 Sep; 100(3):417-23. PubMed ID: 21945857
[TBL] [Abstract][Full Text] [Related]
16. Treatment-planning study of prostate cancer intensity-modulated radiotherapy with a Varian Clinac operated without a flattening filter.
Vassiliev ON; Kry SF; Kuban DA; Salehpour M; Mohan R; Titt U
Int J Radiat Oncol Biol Phys; 2007 Aug; 68(5):1567-71. PubMed ID: 17544596
[TBL] [Abstract][Full Text] [Related]
17. Surface dose variations in 6 and 10 MV flattened and flattening filter-free (FFF) photon beams.
Cashmore J
J Appl Clin Med Phys; 2016 Sep; 17(5):293-307. PubMed ID: 27685127
[TBL] [Abstract][Full Text] [Related]
18. Flattening filter free beams from TrueBeam and Versa HD units: Evaluation of the parameters for quality assurance.
Fogliata A; Fleckenstein J; Schneider F; Pachoud M; Ghandour S; Krauss H; Reggiori G; Stravato A; Lohr F; Scorsetti M; Cozzi L
Med Phys; 2016 Jan; 43(1):205. PubMed ID: 26745913
[TBL] [Abstract][Full Text] [Related]
19. Flattening filter-free accelerators: a report from the AAPM Therapy Emerging Technology Assessment Work Group.
Xiao Y; Kry SF; Popple R; Yorke E; Papanikolaou N; Stathakis S; Xia P; Huq S; Bayouth J; Galvin J; Yin FF
J Appl Clin Med Phys; 2015 May; 16(3):5219. PubMed ID: 26103482
[TBL] [Abstract][Full Text] [Related]
20. Validation of a virtual source model for Monte Carlo dose calculations of a flattening filter free linac.
Cashmore J; Golubev S; Dumont JL; Sikora M; Alber M; Ramtohul M
Med Phys; 2012 Jun; 39(6):3262-9. PubMed ID: 22755709
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]