These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
266 related articles for article (PubMed ID: 21520864)
1. The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources. Landry G; Reniers B; Pignol JP; Beaulieu L; Verhaegen F Med Phys; 2011 Mar; 38(3):1526-33. PubMed ID: 21520864 [TBL] [Abstract][Full Text] [Related]
2. Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition. Landry G; Reniers B; Murrer L; Lutgens L; Gurp EB; Pignol JP; Keller B; Beaulieu L; Verhaegen F Med Phys; 2010 Oct; 37(10):5188-98. PubMed ID: 21089752 [TBL] [Abstract][Full Text] [Related]
3. Dose to tissue medium or water cavities as surrogate for the dose to cell nuclei at brachytherapy photon energies. Enger SA; Ahnesjö A; Verhaegen F; Beaulieu L Phys Med Biol; 2012 Jul; 57(14):4489-500. PubMed ID: 22722477 [TBL] [Abstract][Full Text] [Related]
4. Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant. Furstoss C; Reniers B; Bertrand MJ; Poon E; Carrier JF; Keller BM; Pignol JP; Beaulieu L; Verhaegen F Med Phys; 2009 May; 36(5):1848-58. PubMed ID: 19544804 [TBL] [Abstract][Full Text] [Related]
5. Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source. White SA; Landry G; Fonseca GP; Holt R; Rusch T; Beaulieu L; Verhaegen F; Reniers B Med Phys; 2014 Jun; 41(6):061701. PubMed ID: 24877796 [TBL] [Abstract][Full Text] [Related]
6. A Monte Carlo study on the effect of seed design on the interseed attenuation in permanent prostate implants. Afsharpour H; D'Amours M; Coté B; Carrier JF; Verhaegen F; Beaulieu L Med Phys; 2008 Aug; 35(8):3671-81. PubMed ID: 18777927 [TBL] [Abstract][Full Text] [Related]
7. Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air. Rivard MJ; Granero D; Perez-Calatayud J; Ballester F Med Phys; 2010 Feb; 37(2):869-76. PubMed ID: 20229896 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of brachytherapy lung implant dose distributions from photon-emitting sources due to tissue heterogeneities. Yang Y; Rivard MJ Med Phys; 2011 Nov; 38(11):5857-62. PubMed ID: 22047349 [TBL] [Abstract][Full Text] [Related]
9. Brachytherapy dosimetry of 125I and 103Pd sources using an updated cross section library for the MCNP Monte Carlo transport code. Bohm TD; DeLuca PM; DeWerd LA Med Phys; 2003 Apr; 30(4):701-11. PubMed ID: 12722822 [TBL] [Abstract][Full Text] [Related]
10. Monte Carlo studies on water and LiF cavity properties for dose-reporting quantities when using x-ray and brachytherapy sources. Branco IS; Antunes PC; Fonseca GP; Yoriyaz H Phys Med Biol; 2016 Dec; 61(24):8890-8907. PubMed ID: 27910825 [TBL] [Abstract][Full Text] [Related]
11. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources. Bannon EA; Yang Y; Rivard MJ Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369 [TBL] [Abstract][Full Text] [Related]
12. Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma. Candela-Juan C; Perez-Calatayud J; Ballester F; Rivard MJ Med Phys; 2013 Mar; 40(3):033901. PubMed ID: 23464344 [TBL] [Abstract][Full Text] [Related]
13. Tissue modeling schemes in low energy breast brachytherapy. Afsharpour H; Landry G; Reniers B; Pignol JP; Beaulieu L; Verhaegen F Phys Med Biol; 2011 Nov; 56(22):7045-60. PubMed ID: 22016111 [TBL] [Abstract][Full Text] [Related]
14. Changes in dose with segmentation of breast tissues in Monte Carlo calculations for low-energy brachytherapy. Sutherland JG; Thomson RM; Rogers DW Med Phys; 2011 Aug; 38(8):4858-65. PubMed ID: 21928657 [TBL] [Abstract][Full Text] [Related]
15. EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 137Cs brachytherapy source models. Selvam TP; Sahoo S; Vishwakarma RS Med Phys; 2009 Sep; 36(9):3870-9. PubMed ID: 19810459 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of dosimetric effects of metallic artifact reduction and tissue assignment on Monte Carlo dose calculations for Assam I; Vijande J; Ballester F; Pérez-Calatayud J; Poppe B; Siebert FA Med Phys; 2022 Sep; 49(9):6195-6208. PubMed ID: 35925023 [TBL] [Abstract][Full Text] [Related]
17. Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET. Mason J; Al-Qaisieh B; Bownes P; Henry A; Thwaites D Med Phys; 2013 Mar; 40(3):031717. PubMed ID: 23464312 [TBL] [Abstract][Full Text] [Related]
18. Study of encapsulated 170Tm sources for their potential use in brachytherapy. Ballester F; Granero D; Perez-Calatayud J; Venselaar JL; Rivard MJ Med Phys; 2010 Apr; 37(4):1629-37. PubMed ID: 20443484 [TBL] [Abstract][Full Text] [Related]
19. Cavity theory applications for kilovoltage cellular dosimetry. Oliver PAK; Thomson RM Phys Med Biol; 2017 Jun; 62(11):4440-4459. PubMed ID: 28358721 [TBL] [Abstract][Full Text] [Related]
20. Influence of trace elements in human tissue in low-energy photon brachytherapy dosimetry. White SA; Landry G; van Gils F; Verhaegen F; Reniers B Phys Med Biol; 2012 Jun; 57(11):3585-96. PubMed ID: 22588230 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]