BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 21520871)

  • 1. Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations.
    Wang LL; Beddar S
    Med Phys; 2011 Mar; 38(3):1596-9. PubMed ID: 21520871
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo study of the energy and angular dependence of the response of plastic scintillation detectors in photon beams.
    Wang LL; Klein D; Beddar AS
    Med Phys; 2010 Oct; 37(10):5279-86. PubMed ID: 21089762
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.
    Lessard F; Archambault L; Plamondon M; Despres P; Therriault-Proulx F; Beddar S; Beaulieu L
    Med Phys; 2012 Sep; 39(9):5308-16. PubMed ID: 22957599
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental investigation on the accuracy of plastic scintillators and of the spectrum discrimination method in small photon fields.
    Papaconstadopoulos P; Archambault L; Seuntjens J
    Med Phys; 2017 Feb; 44(2):654-664. PubMed ID: 27997030
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.
    Guillot M; Gingras L; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2011 Apr; 38(4):2140-50. PubMed ID: 21626947
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.
    Klein DM; Tailor RC; Archambault L; Wang L; Therriault-Proulx F; Beddar AS
    Med Phys; 2010 Oct; 37(10):5541-9. PubMed ID: 21089789
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy.
    Guillot M; Beaulieu L; Archambault L; Beddar S; Gingras L
    Med Phys; 2011 Dec; 38(12):6763-74. PubMed ID: 22149858
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife.
    Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Response of plastic scintillators to low-energy photons.
    Peralta L; Rêgo F
    Phys Med Biol; 2014 Aug; 59(16):4621-33. PubMed ID: 25079252
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
    Archambault L; Polf JC; Beaulieu L; Beddar S
    Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Technical Note: Out-of-field dose measurement at near surface with plastic scintillator detector.
    Bourgouin A; Varfalvy N; Archambault L
    J Appl Clin Med Phys; 2016 Sep; 17(5):542-547. PubMed ID: 27685131
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Temperature dependence of BCF plastic scintillation detectors.
    Wootton L; Beddar S
    Phys Med Biol; 2013 May; 58(9):2955-67. PubMed ID: 23574889
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fabrication and characterization of a stemless plastic scintillation detector.
    Hupman MA; Monajemi T; Valitova I; Hill IG; Syme A
    Med Phys; 2020 Nov; 47(11):5882-5889. PubMed ID: 32966652
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of the quenching correction factors for plastic scintillation detectors in therapeutic high-energy proton beams.
    Wang LL; Perles LA; Archambault L; Sahoo N; Mirkovic D; Beddar S
    Phys Med Biol; 2012 Dec; 57(23):7767-81. PubMed ID: 23128412
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy.
    Ebenau M; Radeck D; Bambynek M; Sommer H; Flühs D; Spaan B; Eichmann M
    Med Phys; 2016 Aug; 43(8):4598. PubMed ID: 27487876
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector.
    Therriault-Proulx F; Wootton L; Beddar S
    Phys Med Biol; 2015 Oct; 60(20):7927-39. PubMed ID: 26407188
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo modeling of the influence of strong magnetic fields on the stem-effect in plastic scintillation detectors used in radiotherapy dosimetry.
    Simiele E; Viscariello N; DeWerd L
    Med Phys; 2021 Mar; 48(3):1381-1394. PubMed ID: 33283279
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.
    Qin Y; Zhong H; Wen N; Snyder K; Huang Y; Chetty IJ
    J Appl Clin Med Phys; 2016 Nov; 17(6):379-391. PubMed ID: 27929510
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo investigation of electron fluence perturbation in MRI-guided radiotherapy beams using six commercial radiation detectors.
    Cervantes Y; Duane S; Bouchard H
    Phys Med Biol; 2022 Jan; 67(3):. PubMed ID: 35026745
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Passively scattered proton beam entrance dosimetry with a plastic scintillation detector.
    Wootton L; Holmes C; Sahoo N; Beddar S
    Phys Med Biol; 2015 Feb; 60(3):1185-98. PubMed ID: 25591037
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.