174 related articles for article (PubMed ID: 21541804)
21. The association between bioimpedance analysis and quality of life in pre-dialysis stage 5 chronic kidney disease, hemodialysis and peritoneal dialysis patients.
Yongsiri S; Thammakumpee J; Prongnamchai S; Dinchuthai P; Chueansuwan R; Tangjaturonrasme S; Chaivanit P
J Med Assoc Thai; 2014 Mar; 97(3):293-9. PubMed ID: 25123008
[TBL] [Abstract][Full Text] [Related]
22. Body composition measurements using bioimpedance analysis in peritoneal dialysis patients are affected by the presence of dialysate.
Kang SH; Cho KH; Park JW; Yoon KW; Do JY
Nephrology (Carlton); 2014 Nov; 19(11):727-31. PubMed ID: 25307155
[TBL] [Abstract][Full Text] [Related]
23. Effect of fluid management guided by bioimpedance spectroscopy on cardiovascular parameters in hemodialysis patients: a randomized controlled trial.
Hur E; Usta M; Toz H; Asci G; Wabel P; Kahvecioglu S; Kayikcioglu M; Demirci MS; Ozkahya M; Duman S; Ok E
Am J Kidney Dis; 2013 Jun; 61(6):957-65. PubMed ID: 23415416
[TBL] [Abstract][Full Text] [Related]
24. Influence of peritoneal dialysis solution on measurements of fluid status by bioimpedance spectroscopy.
Parmentier SP; Schirutschke H; Schmitt B; Schewe J; Herbrig K; Pistrosch F; Passauer J
Int Urol Nephrol; 2013 Feb; 45(1):229-32. PubMed ID: 22710970
[TBL] [Abstract][Full Text] [Related]
25. Plasma volume, albumin, and fluid status in peritoneal dialysis patients.
John B; Tan BK; Dainty S; Spanel P; Smith D; Davies SJ
Clin J Am Soc Nephrol; 2010 Aug; 5(8):1463-70. PubMed ID: 20538836
[TBL] [Abstract][Full Text] [Related]
26. The Impact of Volume Overload on the Longitudinal Change of Adipose and Lean Tissue Mass in Incident Chinese Peritoneal Dialysis Patients.
Ng JK; Chan GC; Kam KK; Tian N; Than WH; Cheng PM; Law MC; Pang WF; Szeto CC; Li PK
Nutrients; 2022 Sep; 14(19):. PubMed ID: 36235728
[TBL] [Abstract][Full Text] [Related]
27. Overhydration Is a Strong Predictor of Mortality in Peritoneal Dialysis Patients - Independently of Cardiac Failure.
Jotterand Drepper V; Kihm LP; Kälble F; Diekmann C; Seckinger J; Sommerer C; Zeier M; Schwenger V
PLoS One; 2016; 11(7):e0158741. PubMed ID: 27415758
[TBL] [Abstract][Full Text] [Related]
28. Clinical significance of multi-frequency bioimpedance spectroscopy in peritoneal dialysis patients: independent predictor of patient survival.
O'Lone EL; Visser A; Finney H; Fan SL
Nephrol Dial Transplant; 2014 Jul; 29(7):1430-7. PubMed ID: 24598280
[TBL] [Abstract][Full Text] [Related]
29. Body composition, hydration, and related parameters in hemodialysis versus peritoneal dialysis patients.
Devolder I; Verleysen A; Vijt D; Vanholder R; Van Biesen W
Perit Dial Int; 2010; 30(2):208-14. PubMed ID: 20081049
[TBL] [Abstract][Full Text] [Related]
30. Efficacy of dialysis in peritoneal dialysis: utility of bioimpedance to calculate Kt/V and the search for a target Kt.
Martínez Fernández G; Ortega Cerrato A; Masiá Mondéjar J; Pérez Rodríguez A; Llamas Fuentes F; Gómez Roldán C; Pérez-Martínez J
Clin Exp Nephrol; 2013 Apr; 17(2):261-7. PubMed ID: 22886499
[TBL] [Abstract][Full Text] [Related]
31. Bioimpedance spectroscopy for the detection of fluid overload in Chinese peritoneal dialysis patients.
Kwan BC; Szeto CC; Chow KM; Law MC; Cheng MS; Leung CB; Pang WF; Kwong VW; Li PK
Perit Dial Int; 2014 Jun; 34(4):409-16. PubMed ID: 24385329
[TBL] [Abstract][Full Text] [Related]
32. Clinical Significance of Phase Angle in Non-Dialysis CKD Stage 5 and Peritoneal Dialysis Patients.
Han BG; Lee JY; Kim JS; Yang JW
Nutrients; 2018 Sep; 10(9):. PubMed ID: 30235860
[TBL] [Abstract][Full Text] [Related]
33. Echocardiographic impact of hydration status in dialysis patients.
Juan-García I; Puchades MJ; Sanjuán R; Torregrosa I; Solís MÁ; González M; Blasco M; Martínez A; Miguel A
Nefrologia; 2012; 32(1):94-102. PubMed ID: 22240880
[TBL] [Abstract][Full Text] [Related]
34. Increase in Extracellular Hydration Status After Initiating Peritoneal Dialysis Electively.
Panorchan K; Davenport A
Perit Dial Int; 2017; 37(3):338-340. PubMed ID: 28512162
[TBL] [Abstract][Full Text] [Related]
35. Does peritoneal dialysate affect body composition assessments using multi-frequency bioimpedance in peritoneal dialysis patients?
Davenport A
Eur J Clin Nutr; 2013 Feb; 67(2):223-5. PubMed ID: 23249878
[TBL] [Abstract][Full Text] [Related]
36. Effect of icodextrin on volume status, blood pressure and echocardiographic parameters: a randomized study.
Konings CJ; Kooman JP; Schonck M; Gladziwa U; Wirtz J; van den Wall Bake AW; Gerlag PG; Hoorntje SJ; Wolters J; van der Sande FM; Leunissen KM
Kidney Int; 2003 Apr; 63(4):1556-63. PubMed ID: 12631373
[TBL] [Abstract][Full Text] [Related]
37. Bioimpedance spectroscopy for fluid status assessment in patients with decompensated liver cirrhosis: Implications for peritoneal dialysis.
Schwaiger E; Simon A; Wabel P; Schairer B; Berner C; Signorini L; Ernstbrunner M; Evstatiev R; Schwabl P; Hinterholzer G; Frommlet F; Vychytil A; Müller CJ; Hecking M
Sci Rep; 2020 Feb; 10(1):2869. PubMed ID: 32071351
[TBL] [Abstract][Full Text] [Related]
38. Asymptomatic fluid overload predicts survival and cardiovascular event in incident Chinese peritoneal dialysis patients.
Ng JK; Kwan BC; Chow KM; Pang WF; Cheng PM; Leung CB; Li PK; Szeto CC
PLoS One; 2018; 13(8):e0202203. PubMed ID: 30102739
[TBL] [Abstract][Full Text] [Related]
39. A comparison of fluid status determination using bioelectric impedance and the isotope dilution method in hemodialysis and peritoneal dialysis patients.
Dou Y; Gong Y; Li A; Wang P; Song D; Wang Y; Liu D; Cheng G; Zhao Z
Ren Fail; 2022 Dec; 44(1):1698-1707. PubMed ID: 36262107
[TBL] [Abstract][Full Text] [Related]
40. Relationship between bioimpedance-determined body composition and peritoneal transport in peritoneal dialysis.
da Costa BM; Del Peso G; Bajo MA; Carreño G; Ferreira M; Ferreira C; Selgas R
Int J Artif Organs; 2017 May; 40(5):212-218. PubMed ID: 28525669
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]