These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Fatal late migration of viacor percutaneous transvenous mitral annuloplasty device resulting in distal coronary venous perforation. Machaalany J; St-Pierre A; Sénéchal M; Larose E; Philippon F; Abdelaal E; Charbonneau E; Dagenais F; Trahan S; Bertrand OF Can J Cardiol; 2013 Jan; 29(1):130.e1-4. PubMed ID: 22622003 [TBL] [Abstract][Full Text] [Related]
3. Delayed Asymptomatic Thrombosis and Erosion of the Coronary Sinus After Transvenous Mitral Annuloplasty With the Viacor Device. Radermecker MA; Lancellotti P; Legrand V; Pierard L Ann Thorac Surg; 2016 Jun; 101(6):2391. PubMed ID: 27211957 [No Abstract] [Full Text] [Related]
4. Percutaneous mitral annuloplasty in a patient with coronary sinus stenosis and coronary artery compression during procedure; they will not interfere. Celik T; Ozturk C; Iyisoy A; Demir M; Yildirim AO; Demirkol S; Balta S Int J Cardiol; 2015 Jul; 191():84-6. PubMed ID: 25965609 [No Abstract] [Full Text] [Related]
5. Quadripolar left ventricular lead implantation through the anchor struts of a mitral valve annuloplasty device. Shetty AK; Roy D; Thomas MR; Rinaldi CA Europace; 2011 Apr; 13(4):590-1. PubMed ID: 20974758 [TBL] [Abstract][Full Text] [Related]
6. Percutaneous mitral valve annuloplasty for functional mitral regurgitation: acute results of the first patient treated with the Viacor permanent device and future perspectives. Bertrand OF; Philippon F; St Pierre A; Nguyen CM; Larose E; Bilodeau S; Dagenais F; Charbonneau E; Rodés-Cabau J; Sénéchal M Cardiovasc Revasc Med; 2010; 11(4):265.e1-8. PubMed ID: 20934667 [TBL] [Abstract][Full Text] [Related]
7. Use of cardiac computed tomography prior to percutaneous coronary sinus device placement for the treatment of mitral regurgitation. Gopal A; Budoff MJ; Shavelle DM JACC Cardiovasc Interv; 2011 May; 4(5):593; author reply 593-4. PubMed ID: 21596340 [No Abstract] [Full Text] [Related]
8. Complications during percutaneous edge-to-edge mitral valve repair. Bakker AL; Swaans MJ; van der Heyden JA; Eefting FD; Rensing BJ; Post MC Herz; 2013 Aug; 38(5):484-9. PubMed ID: 23797375 [TBL] [Abstract][Full Text] [Related]
9. Functional mitral stenosis after surgical annuloplasty for ischemic mitral regurgitation: importance of subvalvular tethering in the mechanism and dynamic deterioration during exertion. M Frater RW J Thorac Cardiovasc Surg; 2011 Feb; 141(2):602; author reply 602-3. PubMed ID: 21241876 [No Abstract] [Full Text] [Related]
10. Percutaneous treatment of mitral regurgitation: from feasibility to clinical application? Iung B; Vahanian A Arch Cardiovasc Dis; 2011 Jan; 104(1):1-3. PubMed ID: 21276571 [No Abstract] [Full Text] [Related]
11. Percutaneous transvenous mitral annuloplasty: initial human experience with device implantation in the coronary sinus. Webb JG; Harnek J; Munt BI; Kimblad PO; Chandavimol M; Thompson CR; Mayo JR; Solem JO Circulation; 2006 Feb; 113(6):851-5. PubMed ID: 16461812 [TBL] [Abstract][Full Text] [Related]
12. The more proximal implantation of percutaneous mitral annuloplasty device due to the circumflex artery compression may be less beneficial. Ozturk C; Iyisoy A; Onrat E; Balta S; Celik T Int J Cardiol; 2016 Apr; 209():46-8. PubMed ID: 26878474 [No Abstract] [Full Text] [Related]
14. Reply: Cardiac CT prior to percutaneous coronary sinus-based mitral annuloplasty with the Carillon device. Rottländer D; Gödde M; Degen H; Haude M EuroIntervention; 2020 Nov; 16(10):863-864. PubMed ID: 33215997 [No Abstract] [Full Text] [Related]
15. Morphologic and angiographic analysis to assess the safety of a biodegradable mitral annuloplasty ring. Cikirikcioglu M; Cherian S; Stimec B; Theologou T; Myers PO; Fasel J; Kalangos A J Heart Valve Dis; 2011 Mar; 20(2):199-204. PubMed ID: 21560823 [TBL] [Abstract][Full Text] [Related]
16. Spatial relationship of coronary sinus-great cardiac vein with adjoining anatomic structures: a key element in predicting the success of percutaneous transvenous mitral annuloplasty. Sahni D; Randhawa A; Aggarwal A; Rohit MK J Heart Valve Dis; 2014 Mar; 23(2):184-92. PubMed ID: 25076549 [TBL] [Abstract][Full Text] [Related]
17. Repair for mitral stenosis due to pannus formation after Duran ring annuloplasty. Song S; Cho SH; Yang JH; Park PW Ann Thorac Surg; 2010 Dec; 90(6):e93-4. PubMed ID: 21095295 [TBL] [Abstract][Full Text] [Related]
18. Reversible circumflex coronary artery occlusion during percutaneous transvenous mitral annuloplasty with the Viacor system. Sponga S; Bertrand OF; Philippon F; St Pierre A; Dagenais F; Charbonneau E; Bagur R; Sénéchal M J Am Coll Cardiol; 2012 Jan; 59(3):288. PubMed ID: 22240134 [No Abstract] [Full Text] [Related]
19. Percutaneous mitral annuloplasty through the coronary sinus: an anatomic point of view. Lansac E; Di Centa I; Al Attar N; Messika-Zeitoun D; Raffoul R; Vahanian A; Nataf P J Thorac Cardiovasc Surg; 2008 Feb; 135(2):376-81. PubMed ID: 18242272 [TBL] [Abstract][Full Text] [Related]