These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Internal electrolyte temperatures for polymer and fused-silica capillaries used in capillary electrophoresis. Evenhuis CJ; Guijt RM; Macka M; Marriott PJ; Haddad PR Electrophoresis; 2005 Nov; 26(22):4333-44. PubMed ID: 16287176 [TBL] [Abstract][Full Text] [Related]
4. Improving the reproducibility in capillary electrophoresis by incorporating current drift in mobility and peak area calculations. Petersen NJ; Hansen SH Electrophoresis; 2012 Mar; 33(6):1021-31. PubMed ID: 22528422 [TBL] [Abstract][Full Text] [Related]
5. Influence of solvent on temperature and thermal peak broadening in capillary zone electrophoresis. Porras SP; Marziali E; Gas B; Kenndler E Electrophoresis; 2003 May; 24(10):1553-64. PubMed ID: 12761785 [TBL] [Abstract][Full Text] [Related]
6. Simplified universal method for determining electrolyte temperatures in a capillary electrophoresis instrument with forced-air cooling. Patel KH; Evenhuis CJ; Cherney LT; Krylov SN Electrophoresis; 2012 Mar; 33(6):1079-85. PubMed ID: 22528428 [TBL] [Abstract][Full Text] [Related]
7. Temperature profiles and heat dissipation in capillary electrophoresis. Evenhuis CJ; Guijt RM; Macka M; Marriott PJ; Haddad PR Anal Chem; 2006 Apr; 78(8):2684-93. PubMed ID: 16615780 [TBL] [Abstract][Full Text] [Related]
8. [Temperature measurement in the ear canal: comparison of an infrared thermometer with conventional temperature probes and evaluation of clinical factors on infrared measurement]. Rohrberg M; Fritz U; Weyland W; Braun U Anasthesiol Intensivmed Notfallmed Schmerzther; 1997 Jul; 32(7):409-13. PubMed ID: 9340028 [TBL] [Abstract][Full Text] [Related]
9. Temperature difference between the cooled and the noncooled parts of an electrolyte in capillary electrophoresis. Musheev MU; Filiptsev Y; Krylov SN Anal Chem; 2010 Oct; 82(20):8692-5. PubMed ID: 20853855 [TBL] [Abstract][Full Text] [Related]
10. Universal method for determining electrolyte temperatures in capillary electrophoresis. Evenhuis CJ; Musheev MU; Krylov SN Anal Chem; 2011 Mar; 83(5):1808-14. PubMed ID: 21288017 [TBL] [Abstract][Full Text] [Related]
11. Quantification and evaluation of Joule heating in on-chip capillary electrophoresis. Swinney K; Bornhop DJ Electrophoresis; 2002 Feb; 23(4):613-20. PubMed ID: 11870773 [TBL] [Abstract][Full Text] [Related]
12. Reliability of an infrared forehead skin thermometer for core temperature measurements. Kistemaker JA; Den Hartog EA; Daanen HA J Med Eng Technol; 2006; 30(4):252-61. PubMed ID: 16864237 [TBL] [Abstract][Full Text] [Related]
13. Effect of Joule heating on efficiency and performance for microchip-based and capillary-based electrophoretic separation systems: a closer look. Petersen NJ; Nikolajsen RP; Mogensen KB; Kutter JP Electrophoresis; 2004 Jan; 25(2):253-69. PubMed ID: 14743478 [TBL] [Abstract][Full Text] [Related]
15. Using nonequilibrium capillary electrophoresis of equilibrium mixtures for the determination of temperature in capillary electrophoresis. Berezovski M; Krylov SN Anal Chem; 2004 Dec; 76(23):7114-7. PubMed ID: 15571367 [TBL] [Abstract][Full Text] [Related]
16. Diffusion as a tool of measuring temperature inside a capillary. Musheev MU; Javaherian S; Okhonin V; Krylov SN Anal Chem; 2008 Sep; 80(17):6752-7. PubMed ID: 18672887 [TBL] [Abstract][Full Text] [Related]