273 related articles for article (PubMed ID: 21568983)
1. Evaluation of M43B Lumbar puncture simulator-II as a training tool for identification of the epidural space and lumbar puncture.
Uppal V; Kearns RJ; McGrady EM
Anaesthesia; 2011 Jun; 66(6):493-6. PubMed ID: 21568983
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of a new training device to simulate the epidural and subarachnoid spaces for neuraxial anesthesia techniques.
Capogna G; Stirparo S; Caniggia S
Minerva Anestesiol; 2013 Apr; 79(4):385-90. PubMed ID: 23306396
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of the Mediseus epidural simulator.
Lee RA; van Zundert TC; van Koesveld JJ; van Zundert AA; Stolker RJ; Wieringa PA; Gatt SP
Anaesth Intensive Care; 2012 Mar; 40(2):311-8. PubMed ID: 22417027
[TBL] [Abstract][Full Text] [Related]
4. Teaching neuraxial analgesia: identification of loss of resistance (epidural) and intrathecal (spinal) placement of needles--avoid "making a lemon" of yourself.
van den Berg AA; Liao D
Anesth Analg; 2013 Aug; 117(2):533-4. PubMed ID: 23881378
[No Abstract] [Full Text] [Related]
5. A simulation-based evaluation of two proposed alternatives to Luer devices for use in neuraxial anaesthesia.
Cook TM; Payne S; Skryabina E; Hurford D; Clow E; Georgiou A
Anaesthesia; 2010 Nov; 65(11):1069-79. PubMed ID: 20946390
[TBL] [Abstract][Full Text] [Related]
6. A simple epidural simulator: a blinded study assessing the 'feel' of loss of resistance in four fruits.
Raj D; Williamson RM; Young D; Russell D
Eur J Anaesthesiol; 2013 Jul; 30(7):405-8. PubMed ID: 23749185
[TBL] [Abstract][Full Text] [Related]
7. Teaching practices of thoracic epidural anesthesia in the United States: should lumbar epidurals be taught before thoracic epidurals?
Saied NN; Helwani M; Tabakian H; Srinivasan J
J Cardiothorac Vasc Anesth; 2006 Oct; 20(5):652-5. PubMed ID: 17023282
[TBL] [Abstract][Full Text] [Related]
8. Clinical application of a novel developed pressure bladder indicator in lumbar epidural puncture.
Liu X; Wang EE; Yan Q; Li K
J Clin Anesth; 2015 Nov; 27(7):543-7. PubMed ID: 26298694
[TBL] [Abstract][Full Text] [Related]
9. Development of the force-feedback model for an epidural needle insertion simulator.
Hiemenz L; Stredney D; Schmalbrock P
Stud Health Technol Inform; 1998; 50():272-7. PubMed ID: 10180553
[TBL] [Abstract][Full Text] [Related]
10. Loss of resistance: A randomised controlled trial assessing four low-fidelity epidural puncture simulators.
Pedersen TH; Meuli J; Plazikowski EJ; Buttenberg M; Kleine-Brueggeney M; Seidl C; Theiler L; Greif R
Eur J Anaesthesiol; 2017 Sep; 34(9):602-608. PubMed ID: 28437262
[TBL] [Abstract][Full Text] [Related]
11. Clinical impact of epidural anesthesia simulation on short- and long-term learning curve: High- versus low-fidelity model training.
Friedman Z; Siddiqui N; Katznelson R; Devito I; Bould MD; Naik V
Reg Anesth Pain Med; 2009; 34(3):229-32. PubMed ID: 19587620
[TBL] [Abstract][Full Text] [Related]
12. Prepuncture ultrasound-measured distance: an accurate reflection of epidural depth in infants and small children.
Kil HK; Cho JE; Kim WO; Koo BN; Han SW; Kim JY
Reg Anesth Pain Med; 2007; 32(2):102-6. PubMed ID: 17350519
[TBL] [Abstract][Full Text] [Related]
13. A randomized trial of dural puncture epidural technique compared with the standard epidural technique for labor analgesia.
Cappiello E; O'Rourke N; Segal S; Tsen LC
Anesth Analg; 2008 Nov; 107(5):1646-51. PubMed ID: 18931227
[TBL] [Abstract][Full Text] [Related]
14. Low-Fidelity Haptic Simulation Versus Mental Imagery Training for Epidural Anesthesia Technical Achievement in Novice Anesthesiology Residents: A Randomized Comparative Study.
Lim G; Krohner RG; Metro DG; Rosario BL; Jeong JH; Sakai T
Anesth Analg; 2016 May; 122(5):1516-23. PubMed ID: 27007077
[TBL] [Abstract][Full Text] [Related]
15. Clinical clerkship course for medical students on lumbar puncture using simulators.
Adachi K; Yoshimura A; Aso R; Miyashita T; Yoshida D; Teramoto A; Shimura T
J Nippon Med Sch; 2012; 79(6):430-7. PubMed ID: 23291841
[TBL] [Abstract][Full Text] [Related]
16. Intrathecal catheter insertion during labour reduces the risk of post-dural puncture headache.
Dennehy KC; Rosaeg OP
Can J Anaesth; 1998 Jan; 45(1):42-5. PubMed ID: 9466026
[TBL] [Abstract][Full Text] [Related]
17. Development of artificial tissue-like structures for a hybrid epidural anesthesia simulator.
Esterer B; Razenbock J; Hollensteiner M; Fuerst D; Schrempf A
Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():2099-2102. PubMed ID: 28268745
[TBL] [Abstract][Full Text] [Related]
18. Single-operator real-time ultrasound-guidance to aim and insert a lumbar epidural needle.
Tran D; Kamani AA; Al-Attas E; Lessoway VA; Massey S; Rohling RN
Can J Anaesth; 2010 Apr; 57(4):313-21. PubMed ID: 20196236
[TBL] [Abstract][Full Text] [Related]
19. A prototype haptic lumbar puncture simulator.
Gorman P; Krummel T; Webster R; Smith M; Hutchens D
Stud Health Technol Inform; 2000; 70():106-9. PubMed ID: 10977521
[TBL] [Abstract][Full Text] [Related]
20. Ten years of experience with accidental dural puncture and post-dural puncture headache in a tertiary obstetric anaesthesia department.
Van de Velde M; Schepers R; Berends N; Vandermeersch E; De Buck F
Int J Obstet Anesth; 2008 Oct; 17(4):329-35. PubMed ID: 18691871
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]