These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 21570884)

  • 1. Kilovoltage beam model for flat panel imaging system with bow-tie filter for scatter prediction and correction.
    Blessing M; Bhagwat MS; Lyatskaya Y; Bellon JR; Hesser J; Zygmanski P
    Phys Med; 2012 Apr; 28(2):134-43. PubMed ID: 21570884
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A phenomenological kV beam model for cone-beam imaging.
    Bhagwat MS; Blessing M; Lyatskaya Y; Zygmanski P
    Phys Med Biol; 2010 Oct; 55(19):5787-99. PubMed ID: 20844328
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Algorithm for X-ray scatter, beam-hardening, and beam profile correction in diagnostic (kilovoltage) and treatment (megavoltage) cone beam CT.
    Maltz JS; Gangadharan B; Bose S; Hristov DH; Faddegon BA; Paidi A; Bani-Hashemi AR
    IEEE Trans Med Imaging; 2008 Dec; 27(12):1791-810. PubMed ID: 19033095
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Scatter kernel estimation with an edge-spread function method for cone-beam computed tomography imaging.
    Li H; Mohan R; Zhu XR
    Phys Med Biol; 2008 Dec; 53(23):6729-48. PubMed ID: 18997269
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improved scatter correction using adaptive scatter kernel superposition.
    Sun M; Star-Lack JM
    Phys Med Biol; 2010 Nov; 55(22):6695-720. PubMed ID: 21030750
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Acquisition of MV-scatter-free kilovoltage CBCT images during RapidArc™ or VMAT.
    Ling C; Zhang P; Etmektzoglou T; Star-Lack J; Sun M; Shapiro E; Hunt M
    Radiother Oncol; 2011 Jul; 100(1):145-9. PubMed ID: 21821301
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Correction of image artifacts from treatment couch in cone-beam CT from kV on-board imaging.
    Ali I; Ahmad S; Alsbou N; Lovelock DM; Kriminski S; Amols H
    J Xray Sci Technol; 2011; 19(3):321-32. PubMed ID: 21876282
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy.
    Ding GX; Duggan DM; Coffey CW
    Phys Med Biol; 2007 Mar; 52(6):1595-615. PubMed ID: 17327651
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of flat panel-imager veiling glare on scatter-estimation accuracy and image quality of a commercial on-board cone-beam CT imaging system.
    Lazos D; Williamson JF
    Med Phys; 2012 Sep; 39(9):5639-51. PubMed ID: 22957630
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A megavoltage scatter correction technique for cone-beam CT images acquired during VMAT delivery.
    Boylan CJ; Marchant TE; Stratford J; Malik J; Choudhury A; Shrimali R; Rodgers J; Rowbottom CG
    Phys Med Biol; 2012 Jun; 57(12):3727-39. PubMed ID: 22617805
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dose calculation accuracy using cone-beam CT (CBCT) for pelvic adaptive radiotherapy.
    Guan H; Dong H
    Phys Med Biol; 2009 Oct; 54(20):6239-50. PubMed ID: 19794241
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calibration of megavoltage cone-beam CT for radiotherapy dose calculations: correction of cupping artifacts and conversion of CT numbers to electron density.
    Petit SF; van Elmpt WJ; Nijsten SM; Lambin P; Dekker AL
    Med Phys; 2008 Mar; 35(3):849-65. PubMed ID: 18404922
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part II: System modeling, scatter correction, and optimization.
    Wang A; Maslowski A; Messmer P; Lehmann M; Strzelecki A; Yu E; Paysan P; Brehm M; Munro P; Star-Lack J; Seghers D
    Med Phys; 2018 May; 45(5):1914-1925. PubMed ID: 29509973
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Projection correlation based view interpolation for cone beam CT: primary fluence restoration in scatter measurement with a moving beam stop array.
    Yan H; Mou X; Tang S; Xu Q; Zankl M
    Phys Med Biol; 2010 Nov; 55(21):6353-75. PubMed ID: 20938067
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.
    Siewerdsen JH; Jaffray DA
    Med Phys; 2001 Feb; 28(2):220-31. PubMed ID: 11243347
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT.
    Bootsma GJ; Verhaegen F; Jaffray DA
    Med Phys; 2011 Feb; 38(2):897-914. PubMed ID: 21452727
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-quality 3D correction of ring and radiant artifacts in flat panel detector-based cone beam volume CT imaging.
    Anas EM; Kim JG; Lee SY; Hasan MK
    Phys Med Biol; 2011 Oct; 56(19):6495-519. PubMed ID: 21934193
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Empirical binary tomography calibration (EBTC) for the precorrection of beam hardening and scatter for flat panel CT.
    Grimmer R; Kachelriess M
    Med Phys; 2011 Apr; 38(4):2233-40. PubMed ID: 21626957
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Separable scatter model of the detector and object contributions using continuously thickness-adapted kernels in CBCT.
    Bhatia N; Tisseur D; Valton S; Létang JM
    J Xray Sci Technol; 2016 Oct; 24(5):723-732. PubMed ID: 27716681
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a two-dimensional Moire-free antiscatter grid for cone-beam computed tomography.
    Kim J; Kang Y; Hwang T; Park M; Chung W
    Med Phys; 2023 Jun; 50(6):3435-3444. PubMed ID: 36748167
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.