These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 21574878)

  • 1. Monoclonal gammopathy missed by capillary zone electrophoresis.
    Schild C; Egger F; Kaelin-Lang A; Nuoffer JM
    Clin Chem Lab Med; 2011 Jul; 49(7):1217-9. PubMed ID: 21574878
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High false-positive rate for monoclonal gammopathy using capillary electrophoresis (CAPILLARYS 2) alone.
    Huang RS; Oleske DA; Tholpady A; Chang BN; Dasgupta A; Nguyen A; Wahed A
    J Clin Lab Anal; 2014 Jan; 28(1):42-6. PubMed ID: 24375896
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Linearity and detection limit in the measurement of serum M-protein with the capillary zone electrophoresis system Capillarys.
    Bergón E; Miranda I; Miravalles E
    Clin Chem Lab Med; 2005; 43(7):721-3. PubMed ID: 16207131
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Challenges in identifying some IgM monoclonal proteins by capillary serum protein electrophoresis.
    Bailey D; Lem-Ragosnig B; Chan PC
    Clin Biochem; 2013 Nov; 46(16-17):1776-7. PubMed ID: 23872206
    [No Abstract]   [Full Text] [Related]  

  • 5. False-negative result in the detection of an IgM monoclonal protein by capillary zone electrophoresis.
    Zetterberg H; Nilsson-Ehle H
    Clin Chem; 2004 Oct; 50(10):1878-80. PubMed ID: 15292071
    [No Abstract]   [Full Text] [Related]  

  • 6. [A monoclonal immunoglobulin M not visible on the profile of serum capillary electrophoresis].
    Szymanowicz A; Doche C; Schemitick I
    Ann Biol Clin (Paris); 2008; 66(4):465-9. PubMed ID: 18725351
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Concordance of Capillary Electrophoresis and Conventional Gel Electrophoresis in Two Different Groups of Patients with.
    Kim S; Yang HS; Lee A; Cho SY
    Clin Lab; 2018 Mar; 64(3):339-344. PubMed ID: 29739120
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance evaluation of the Helena V8 capillary electrophoresis system.
    Poisson J; Fedoriw Y; Henderson MP; Hainsworth S; Tucker K; Uddin Z; McCudden CR
    Clin Biochem; 2012 Jun; 45(9):697-9. PubMed ID: 22465274
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Detecting a peak in fraction beta by capillary electrophoresis: interference due to iomeprol].
    Wils J; Lavoinne A; Vaillant C
    Ann Biol Clin (Paris); 2013; 71(2):196-8. PubMed ID: 23587586
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of denatured serum proteins in the casein fraction of heat-treated milk by capillary zone electrophoresis.
    Recio I; Olieman C
    Electrophoresis; 1996 Jul; 17(7):1228-33. PubMed ID: 8855409
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of the Sebia CAPILLARYS 2 for detection and immunotyping of serum monoclonal paraproteins.
    Yang Z; Harrison K; Park YA; Chaffin CH; Thigpen B; Easley PL; Smith JA; Robinson CA; Lorenz RG; Hardy RW
    Am J Clin Pathol; 2007 Aug; 128(2):293-9. PubMed ID: 17638665
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection and identification of monoclonal gammopathies by capillary electrophoresis.
    Henskens Y; de Winter J; Pekelharing M; Ponjee G
    Clin Chem; 1998 Jun; 44(6 Pt 1):1184-90. PubMed ID: 9625041
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A preliminary evaluation of serum proteins by capillary electrophoresis.
    Wong MS; Aw TC
    J Capillary Electrophor; 1998; 5(5-6):217-21. PubMed ID: 10812430
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Conflicting results between electrophoresis methods of serum M-proteins.
    Wuyts B; Bossuyt X; Verhoef G; Blanckaert N; Delanghe JR
    Electrophoresis; 2004 Jun; 25(10-11):1548-50. PubMed ID: 15188240
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interpretation and clinical significance of small monoclonal peaks in capillary electrophoresis.
    Cho SY; Jeon YL; You E; Lee HJ; Park TS
    Ann Clin Lab Sci; 2013; 43(3):285-8. PubMed ID: 23884223
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Screening and Diagnosis of Monoclonal Gammopathies: An International Survey of Laboratory Practice.
    Genzen JR; Murray DL; Abel G; Meng QH; Baltaro RJ; Rhoads DD; Delgado JC; Souers RJ; Bashleben C; Keren DF; Ansari MQ
    Arch Pathol Lab Med; 2018 Apr; 142(4):507-515. PubMed ID: 29266967
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Applied capillary electrophoresis system affects screening for monoclonal gammopathy in serum: verification study of two eight-capillary systems.
    Šegulja D; Šparakl T; Rogić D
    Scand J Clin Lab Invest; 2022 Apr; 82(2):85-89. PubMed ID: 35112636
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Inability to Measure M-Protein With Capillary Zone Electrophoresis (CAPPILLARYS 2) in Tracings With NonDiscernable Peaks.
    Huang RS; Dasgupta A; Nguyen AN; Wahed A
    J Clin Lab Anal; 2015 Sep; 29(5):343-6. PubMed ID: 25130914
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of serum protein separation by capillary electrophoresis: prospective analysis of 1000 specimens.
    Jenkins MA; Kulinskaya E; Martin HD; Guerin MD
    J Chromatogr B Biomed Appl; 1995 Oct; 672(2):241-51. PubMed ID: 8581130
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of M-protein quantification using capillary electrophoresis and immunosubtraction-based integration in clinical samples with low M-protein concentrations.
    Cho H; Jung J; Chae H; Joong Lee J; Kim M; Oh EJ; Kim Y; Min CK
    Clin Biochem; 2022 Sep; 107():7-12. PubMed ID: 35660484
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.