BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

261 related articles for article (PubMed ID: 21577124)

  • 1. Multicenter comparison of high concentration contrast agent iomeprol-400 with iso-osmolar iodixanol-320: contrast enhancement and heart rate variation in coronary dual-source computed tomographic angiography.
    Becker CR; Vanzulli A; Fink C; de Faveri D; Fedeli S; Dore R; Biondetti P; Kuettner A; Krix M; Ascenti G
    Invest Radiol; 2011 Jul; 46(7):457-64. PubMed ID: 21577124
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Coronary stent evaluation with coronary computed tomographic angiography: comparison between low-osmolar, high-iodine concentration iomeprol-400 and iso-osmolar, lower-iodine concentration iodixanol-320.
    Andreini D; Pontone G; Mushtaq S; Bartorelli AL; Conte E; Bertella E; Baggiano A; Annoni A; Formenti A; Ballerini G; Agostoni P; Fiorentini C; Pepi M
    J Cardiovasc Comput Tomogr; 2014; 8(1):44-51. PubMed ID: 24582042
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of the efficacy and safety of iopamidol-370 and iodixanol-320 in patients undergoing multidetector-row computed tomography.
    Sahani DV; Soulez G; Chen KM; Lepanto L; Xu JR; Nelson RC; Grazioli L; Vanzulli A; Heiken JP;
    Invest Radiol; 2007 Dec; 42(12):856-61. PubMed ID: 18007158
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of non-ionic iodinated contrast media on patient heart rate and pressures during intra-cardiac or intra-arterial injection.
    Schmid I; Didier D; Pfammatter T; Garachemani A; Fleisch M; Kirchin MA; Meier B
    Int J Cardiol; 2007 Jun; 118(3):389-96. PubMed ID: 17376548
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Heart rate variability and heat sensation during CT coronary angiography: Low-osmolar versus iso-osmolar contrast media.
    Svensson A; Ripsweden J; Rück A; Aspelin P; Cederlund K; Brismar BT
    Acta Radiol; 2010 Sep; 51(7):722-6. PubMed ID: 20568977
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of the effect of low- and iso-osmolar contrast agents on heart rate during chest CT angiography: results of a prospective randomized multicenter study.
    Chartrand-Lefebvre C; White CS; Bhalla S; Mayo-Smith WW; Prenovault J; Vydareny KH; Soto JA; Ozkan OS; Chughtai AR; Soulez G
    Radiology; 2011 Mar; 258(3):930-7. PubMed ID: 21212367
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of a low-osmolar contrast medium, iopamidol, and an iso-osmolar contrast medium, iodixanol, in MDCT coronary angiography.
    Ozbulbul NI; Yurdakul M; Tola M
    Coron Artery Dis; 2010 Nov; 21(7):414-9. PubMed ID: 20671550
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Four-detector row computed tomographic angiography in the evaluation of infrarenal aorta and peripheral arterial occlusive disease: influence of contrast medium concentration.
    Iezzi R; Cotroneo AR; Filippone A; Giancristofaro D; Storto ML
    J Comput Assist Tomogr; 2008; 32(5):690-6. PubMed ID: 18830096
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Enhancement and safety of iomeprol-400 and iodixanol-320 in patients undergoing abdominal multidetector CT.
    Romano L; Grazioli L; Bonomo L; Xu JR; Chen KM; Dore R; Vanzulli A; Catalano C
    Br J Radiol; 2009 Mar; 82(975):204-11. PubMed ID: 19064592
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Influence of Contrast Agent's Osmolarity on Iodine Delivery Protocol in Coronary Computed Tomography Angiography: Comparison Between Iso-Osmolar Iodixanol-320 and Low-Osmolar Iomeprol-370.
    Yang X; Huang W; Liu W; Zhu Y; Xu Y; Yang G; Tang L; Zhu X
    J Comput Assist Tomogr; 2018; 42(1):62-67. PubMed ID: 28708716
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Iodixanol versus Iopromide at Coronary CT Angiography: Lumen Opacification and Effect on Heart Rhythm-the Randomized IsoCOR Trial.
    Lubbers MM; Kock M; Niezen A; Galema T; Kofflard M; Bruning T; Kooij HS; van Valen H; Dijkshoorn M; Booij R; Padmos A; Vogels A; Budde RPJ; Nieman K
    Radiology; 2018 Jan; 286(1):71-80. PubMed ID: 28809582
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Contrast bolus optimization for cardiac 16-slice computed tomography: comparison of contrast medium formulations containing 300 and 400 milligrams of iodine per milliliter.
    Rist C; Nikolaou K; Kirchin MA; van Gessel R; Bae KT; von Ziegler F; Knez A; Wintersperger BJ; Reiser MF; Becker CR
    Invest Radiol; 2006 May; 41(5):460-7. PubMed ID: 16625109
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography: iopromide 370 versus iomeprol 400.
    Cademartiri F; de Monye C; Pugliese F; Mollet NR; Runza G; van der Lugt A; Midiri M; de Feyter PJ; Lagalla R; Krestin GP
    Invest Radiol; 2006 Mar; 41(3):349-53. PubMed ID: 16481919
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic Accuracy, Image Quality, and Patient Comfort for Coronary CT Angiography Performed Using Iso-Osmolar versus Low-Osmolar Iodinated Contrast: A Prospective International Multicenter Randomized Controlled Trial.
    Nakazato R; Arsanjani R; Shalev A; Leipsic JA; Gransar H; Lin FY; Gomez M; Berman DS; Min JK
    Acad Radiol; 2016 Jun; 23(6):743-51. PubMed ID: 27178781
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Coronary computed tomographic angiography in coronary artery bypass grafts: comparison between low-concentration Iodixanol 270 and Iohexol 350.
    Wang H; Xu L; Zhang N; Fan Z; Zhang Z; Sun Z
    J Comput Assist Tomogr; 2015; 39(1):112-8. PubMed ID: 25299799
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The ACTIVE Trial: comparison of the effects on renal function of iomeprol-400 and iodixanol-320 in patients with chronic kidney disease undergoing abdominal computed tomography.
    Thomsen HS; Morcos SK; Erley CM; Grazioli L; Bonomo L; Ni Z; Romano L;
    Invest Radiol; 2008 Mar; 43(3):170-8. PubMed ID: 18301313
    [TBL] [Abstract][Full Text] [Related]  

  • 17. 80-kV pulmonary CT angiography with 40 mL of iodinated contrast material in lean patients: comparison of vascular enhancement with iodixanol (320 mg I/mL)and iomeprol (400 mg I/mL).
    Faggioni L; Neri E; Sbragia P; Pascale R; D'Errico L; Caramella D; Bartolozzi C
    AJR Am J Roentgenol; 2012 Dec; 199(6):1220-5. PubMed ID: 23169711
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of iopamidol-370 versus iodixanol-320 on coronary contrast, branch depiction, and heart rate variability in dual-source coronary MDCT angiography.
    Christensen JD; Meyer LT; Hurwitz LM; Boll DT
    AJR Am J Roentgenol; 2011 Sep; 197(3):W445-51. PubMed ID: 21862771
    [TBL] [Abstract][Full Text] [Related]  

  • 19. MDCT angiography for detection of pulmonary emboli: comparison between equi-iodine doses of iomeprol 400 mgI/mL and iodixanol 320 mgI/mL.
    Langenberger H; Friedrich K; Plank C; Matzek W; Wolf F; Storto ML; Schaefer-Prokop C; Herold C
    Eur J Radiol; 2009 Jun; 70(3):579-88. PubMed ID: 18384995
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Choice of contrast medium in patients with impaired renal function undergoing percutaneous coronary intervention.
    Wessely R; Koppara T; Bradaric C; Vorpahl M; Braun S; Schulz S; Mehilli J; Schömig A; Kastrati A;
    Circ Cardiovasc Interv; 2009 Oct; 2(5):430-7. PubMed ID: 20031753
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.