463 related articles for article (PubMed ID: 21591801)
1. In vivo osseointegration of nano-designed composite coatings on titanium implants.
Facca S; Lahiri D; Fioretti F; Messadeq N; Mainard D; Benkirane-Jessel N; Agarwal A
ACS Nano; 2011 Jun; 5(6):4790-9. PubMed ID: 21591801
[TBL] [Abstract][Full Text] [Related]
2. Comparison of plasma-sprayed hydroxyapatite coatings and zirconia-reinforced hydroxyapatite composite coatings: in vivo study.
Lee TM; Yang CY; Chang E; Tsai RS
J Biomed Mater Res A; 2004 Dec; 71(4):652-60. PubMed ID: 15505828
[TBL] [Abstract][Full Text] [Related]
3. Hot isostatic pressing-processed hydroxyapatite-coated titanium implants: light microscopic and scanning electron microscopy investigations.
Wie H; Herø H; Solheim T
Int J Oral Maxillofac Implants; 1998; 13(6):837-44. PubMed ID: 9857595
[TBL] [Abstract][Full Text] [Related]
4. The role of titanium implant surface modification with hydroxyapatite nanoparticles in progressive early bone-implant fixation in vivo.
Lin A; Wang CJ; Kelly J; Gubbi P; Nishimura I
Int J Oral Maxillofac Implants; 2009; 24(5):808-16. PubMed ID: 19865620
[TBL] [Abstract][Full Text] [Related]
5. A comparative study of zinc, magnesium, strontium-incorporated hydroxyapatite-coated titanium implants for osseointegration of osteopenic rats.
Tao ZS; Zhou WS; He XW; Liu W; Bai BL; Zhou Q; Huang ZL; Tu KK; Li H; Sun T; Lv YX; Cui W; Yang L
Mater Sci Eng C Mater Biol Appl; 2016 May; 62():226-32. PubMed ID: 26952418
[TBL] [Abstract][Full Text] [Related]
6. Mechanical and histological fixation of hydroxylapatite-coated pyrolytic carbon and titanium alloy implants: a report of short-term results.
Hetherington VJ; Lord CE; Brown SA
J Appl Biomater; 1995; 6(4):243-8. PubMed ID: 8589509
[TBL] [Abstract][Full Text] [Related]
7. Osseointegration of a hydroxyapatite-coated multilayered mesh stem.
Kusakabe H; Sakamaki T; Nihei K; Oyama Y; Yanagimoto S; Ichimiya M; Kimura J; Toyama Y
Biomaterials; 2004 Jul; 25(15):2957-69. PubMed ID: 14967528
[TBL] [Abstract][Full Text] [Related]
8. Mechanical and in vitro biological performances of hydroxyapatite-carbon nanotube composite coatings deposited on Ti by aerosol deposition.
Hahn BD; Lee JM; Park DS; Choi JJ; Ryu J; Yoon WH; Lee BK; Shin DS; Kim HE
Acta Biomater; 2009 Oct; 5(8):3205-14. PubMed ID: 19446047
[TBL] [Abstract][Full Text] [Related]
9. Intermittent administration of human parathyroid hormone (1-34) increases fixation of strontium-doped hydroxyapatite coating titanium implants via electrochemical deposition in ovariectomized rat femur.
Tao ZS; Zhou WS; Qiang Z; Tu KK; Huang ZL; Xu HM; Sun T; Lv YX; Cui W; Yang L
J Biomater Appl; 2016 Feb; 30(7):952-60. PubMed ID: 26482573
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of titanium plasma-sprayed and plasma-sprayed hydroxyapatite implants in vivo.
Ong JL; Carnes DL; Bessho K
Biomaterials; 2004 Aug; 25(19):4601-6. PubMed ID: 15120505
[TBL] [Abstract][Full Text] [Related]
11. Effect of hydroxyapatite/tricalcium-phosphate coating on osseointegration of plasma-sprayed titanium alloy implants.
Stewart M; Welter JF; Goldberg VM
J Biomed Mater Res A; 2004 Apr; 69(1):1-10. PubMed ID: 14999745
[TBL] [Abstract][Full Text] [Related]
12. In vivo evaluation of plasma-sprayed titanium coating after alkali modification.
Xue W; Liu X; Zheng X; Ding C
Biomaterials; 2005 Jun; 26(16):3029-37. PubMed ID: 15603798
[TBL] [Abstract][Full Text] [Related]
13. Bone bonding to hydroxyapatite and titanium surfaces on femoral stems retrieved from human subjects at autopsy.
Porter AE; Taak P; Hobbs LW; Coathup MJ; Blunn GW; Spector M
Biomaterials; 2004 Sep; 25(21):5199-208. PubMed ID: 15109844
[TBL] [Abstract][Full Text] [Related]
14. Biological performance of chemical hydroxyapatite coating associated with implant surface modification by laser beam: biomechanical study in rabbit tibias.
Faeda RS; Tavares HS; Sartori R; Guastaldi AC; Marcantonio E
J Oral Maxillofac Surg; 2009 Aug; 67(8):1706-15. PubMed ID: 19615586
[TBL] [Abstract][Full Text] [Related]
15. [Improved osseointegration of titanium implants of different surface characteristics by the use of bone morphogenetic protein (BMP-3): an animal study performed at the metaphyseal bone bed in dogs].
Hartwig CH; Esenwein SA; Pfund A; Küsswetter Dagger W; Herr G
Z Orthop Ihre Grenzgeb; 2003; 141(6):705-11. PubMed ID: 14679438
[TBL] [Abstract][Full Text] [Related]
16. In vivo comparison of the osseointegration of vacuum plasma sprayed titanium- and hydroxyapatite-coated implants.
Aebli N; Krebs J; Stich H; Schawalder P; Walton M; Schwenke D; Gruner H; Gasser B; Theis JC
J Biomed Mater Res A; 2003 Aug; 66(2):356-63. PubMed ID: 12889006
[TBL] [Abstract][Full Text] [Related]
17. Histological and mechanical comparison of hydroxyapatite-coated cobalt-chrome and titanium implants in the rabbit femur.
Friedman RJ; Bauer TW; Garg K; Jiang M; An YH; Draughn RA
J Appl Biomater; 1995; 6(4):231-5. PubMed ID: 8589507
[TBL] [Abstract][Full Text] [Related]
18. Pedicle screw surface coatings improve fixation in nonfusion spinal constructs.
Upasani VV; Farnsworth CL; Tomlinson T; Chambers RC; Tsutsui S; Slivka MA; Mahar AT; Newton PO
Spine (Phila Pa 1976); 2009 Feb; 34(4):335-43. PubMed ID: 19182704
[TBL] [Abstract][Full Text] [Related]
19. Effect of hydroxyapatite coating crystallinity on dissolution and osseointegration in vivo.
Xue W; Liu X; Zheng X; Ding C
J Biomed Mater Res A; 2005 Sep; 74(4):553-61. PubMed ID: 16025491
[TBL] [Abstract][Full Text] [Related]
20. In vivo evaluation of hydroxyapatite coatings of different crystallinities.
Oh S; Tobin E; Yang Y; Carnes DL; Ong JL
Int J Oral Maxillofac Implants; 2005; 20(5):726-31. PubMed ID: 16274146
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]