These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 21602977)

  • 1. Suction conditions for minimizing the production of free hemoglobin during blood salvage using an autotransfusion apparatus.
    An SB; Choi ES; Ahn W
    Korean J Anesthesiol; 2011 Apr; 60(4):266-71. PubMed ID: 21602977
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Suction-induced hemolysis at various vacuum pressures: implications for intraoperative blood salvage.
    Gregoretti S
    Transfusion; 1996 Jan; 36(1):57-60. PubMed ID: 8607155
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of hemolysis and red cell mechanical fragility in blood collected with different cell salvage suction devices.
    Yazer MH; Waters JH; Elkin KR; Rohrbaugh ME; Kameneva MV
    Transfusion; 2008 Jun; 48(6):1188-91. PubMed ID: 18346016
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Modification of suction-induced hemolysis during cell salvage.
    Waters JH; Williams B; Yazer MH; Kameneva MV
    Anesth Analg; 2007 Mar; 104(3):684-7. PubMed ID: 17312230
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro analysis of cell salvage blood collection with a laparoscopic suction device.
    Nagarsheth NP; Fenske SS; Shah A; Moshier E; Stahl R; Shander A
    J Minim Invasive Gynecol; 2013; 20(1):104-6. PubMed ID: 23312250
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A low-hemolysis blood aspirator conserves blood during surgery.
    Clague CT; Blackshear PL
    Biomed Instrum Technol; 1995; 29(5):419-24. PubMed ID: 7496409
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of different autotransfusion devices on the quality of salvaged blood.
    Reents W; Babin-Ebell J; Misoph MR; Schwarzkopf A; Elert O
    Ann Thorac Surg; 1999 Jul; 68(1):58-62. PubMed ID: 10421115
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of transfusion load and suction pressure on renal function in intraoperative salvage autotransfusion.
    Zeng J; Zhang S; Wu Q; Li S; Chen Y; Wu B
    Braz J Med Biol Res; 2021; 54(3):e10292. PubMed ID: 33470391
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Autologous Transfusion of Blood Aspirated during Suction Decompression in Clipping of Large or Giant Cerebral Aneurysm.
    Matsuzawa R; Murata H; Sato M; Miyazaki R; Tanaka T; Shimizu N; Tateishi K; Suenaga J; Yamamoto T
    Neurol Med Chir (Tokyo); 2019 Sep; 59(9):351-356. PubMed ID: 31231087
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An atraumatic aspirator for use in autologous transfusion and cardiac bypass.
    Clague CT; Blackshear PL
    ASAIO J; 1995; 41(3):M551-6. PubMed ID: 8573866
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improving hemolysis levels associated with cardiotomy suction.
    Arensdorf J; Petitt H; Holt D
    Perfusion; 2018 Nov; 33(8):612-617. PubMed ID: 29792111
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new neurosurgical adjustable pressure suction apparatus with a mechanically controlled air inlet: the study of precise regulation and atraumatic suction.
    Nie P; Chen M; Zhang J; Pan M; Gu X; Xu C; Li Z; Zhang J; Zhao W; Li X; Zhang J; Chen J
    Front Neurol; 2022; 13():979494. PubMed ID: 36204001
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of a novel turbulence-controlled suction system in the prevention of hemolysis and platelet dysfunction in autologous surgery blood.
    Budde H; Riggert J; Vormfelde S; Tirilomis T; Friedrich MG
    Perfusion; 2019 Jan; 34(1):58-66. PubMed ID: 30052109
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A New Evaluation
    Iwanowski I; Böckhaus J; Richardt P; Kutschka I; Hanekop GG; Friedrich MG
    J Extra Corpor Technol; 2022 Jun; 54(2):107-114. PubMed ID: 35928337
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Hemolytic characteristics of three suctioning systems for use with a newly developed cardiopulmonary bypass system.
    Michinaga Y; Takano T; Terasaki T; Miyazaki S; Kikuchi N; Okada K
    Perfusion; 2019 Mar; 34(2):136-142. PubMed ID: 30124127
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The impact of roller pump-assisted cardiotomy suction unit on hemolysis.
    Jahren SE; Jenni H; Roesch Y; Arn R; Tevaearai H; Obrist D; Carrel T; Erdoes G
    Artif Organs; 2021 Jan; 45(1):46-54. PubMed ID: 32619302
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Postoperative Blood Salvage and Autotransfusion for Adult Spinal Deformity: A Randomized Controlled Trial.
    Nemani VM; Kim HJ; Mina CA; Sheha ED; Ross T; Boachie-Adjei O
    Spine (Phila Pa 1976); 2020 Sep; 45(18):1247-1252. PubMed ID: 31361726
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Smart suction device for less blood trauma: a comparison with Cell Saver.
    Mueller XM; Tevaearai HT; Horisberger J; Augstburger M; Boone Y; von Segesser LK
    Eur J Cardiothorac Surg; 2001 Apr; 19(4):507-11. PubMed ID: 11306321
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving autologous blood harvest: recovery of red cells from sponges and suction.
    Ronai AK; Glass JJ; Shapiro AS
    Anaesth Intensive Care; 1987 Nov; 15(4):421-4. PubMed ID: 3425881
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quality of the blood sampled from surgical drainage after total hip arthroplasty.
    Tripković B; Buković D; Sakić K; Sakić S; Buković N; Radaković B
    Coll Antropol; 2008 Mar; 32(1):153-60. PubMed ID: 18494201
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.