These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 21604290)

  • 1. Parallel reconstruction using null operations.
    Zhang J; Liu C; Moseley ME
    Magn Reson Med; 2011 Nov; 66(5):1241-53. PubMed ID: 21604290
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Parallel imaging reconstruction using spatial nulling maps.
    Hu J; Yi Z; Zhao Y; Zhang J; Xiao L; Man C; Lau V; Leong ATL; Chen F; Wu EX
    Magn Reson Med; 2023 Aug; 90(2):502-519. PubMed ID: 37010506
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improving GRAPPA using cross-sampled autocalibration data.
    Wang H; Liang D; King KF; Nagarsekar G; Chang Y; Ying L
    Magn Reson Med; 2012 Apr; 67(4):1042-53. PubMed ID: 22135234
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Generalized autocalibrating partially parallel acquisitions (GRAPPA).
    Griswold MA; Jakob PM; Heidemann RM; Nittka M; Jellus V; Wang J; Kiefer B; Haase A
    Magn Reson Med; 2002 Jun; 47(6):1202-10. PubMed ID: 12111967
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Iterative Schemes to Solve Low-Dimensional Calibration Equations in Parallel MR Image Reconstruction with GRAPPA.
    Inam O; Qureshi M; Malik SA; Omer H
    Biomed Res Int; 2017; 2017():3872783. PubMed ID: 29119106
    [TBL] [Abstract][Full Text] [Related]  

  • 6. SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space.
    Lustig M; Pauly JM
    Magn Reson Med; 2010 Aug; 64(2):457-71. PubMed ID: 20665790
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Iterative GRAPPA (iGRAPPA) for improved parallel imaging reconstruction.
    Zhao T; Hu X
    Magn Reson Med; 2008 Apr; 59(4):903-7. PubMed ID: 18383282
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cross-validation-based kernel support selection for improved GRAPPA reconstruction.
    Nana R; Zhao T; Heberlein K; LaConte SM; Hu X
    Magn Reson Med; 2008 Apr; 59(4):819-25. PubMed ID: 18383295
    [TBL] [Abstract][Full Text] [Related]  

  • 9. k-space inherited parallel acquisition (KIPA): application on dynamic magnetic resonance imaging thermometry.
    Guo JY; Kholmovski EG; Zhang L; Jeong EK; Parker DL
    Magn Reson Imaging; 2006 Sep; 24(7):903-15. PubMed ID: 16916708
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of reconstruction and acquisition parameters for GRAPPA-based parallel imaging on the image quality.
    Bauer S; Markl M; Honal M; Jung BA
    Magn Reson Med; 2011 Aug; 66(2):402-9. PubMed ID: 21381100
    [TBL] [Abstract][Full Text] [Related]  

  • 11. GRAPPA reconstruction with spatially varying calibration of self-constraint.
    Xu L; Guo L; Liu X; Kang L; Chen W; Feng Y
    Magn Reson Med; 2015 Oct; 74(4):1057-69. PubMed ID: 25311235
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A radial self-calibrated (RASCAL) generalized autocalibrating partially parallel acquisition (GRAPPA) method using weight interpolation.
    Codella NC; Spincemaille P; Prince M; Wang Y
    NMR Biomed; 2011 Aug; 24(7):844-54. PubMed ID: 21834008
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Instrument Variables for Reducing Noise in Parallel MRI Reconstruction.
    Chang Y; Wang H; Zheng Y; Lin H
    Biomed Res Int; 2017; 2017():9016826. PubMed ID: 28197419
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Image reconstruction with low-rankness and self-consistency of k-space data in parallel MRI.
    Zhang X; Guo D; Huang Y; Chen Y; Wang L; Huang F; Xu Q; Qu X
    Med Image Anal; 2020 Jul; 63():101687. PubMed ID: 32294605
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accelerating GRAPPA reconstruction using SoC design for real-time cardiac MRI.
    Basit A; Inam O; Omer H
    Comput Biol Med; 2023 Jun; 160():107008. PubMed ID: 37159960
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sparsity-promoting calibration for GRAPPA accelerated parallel MRI reconstruction.
    Weller DS; Polimeni JR; Grady L; Wald LL; Adalsteinsson E; Goyal VK
    IEEE Trans Med Imaging; 2013 Jul; 32(7):1325-35. PubMed ID: 23584259
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Adaptive self-calibrating iterative GRAPPA reconstruction.
    Park S; Park J
    Magn Reson Med; 2012 Jun; 67(6):1721-9. PubMed ID: 21994010
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improving parallel imaging by jointly reconstructing multi-contrast data.
    Bilgic B; Kim TH; Liao C; Manhard MK; Wald LL; Haldar JP; Setsompop K
    Magn Reson Med; 2018 Aug; 80(2):619-632. PubMed ID: 29322551
    [TBL] [Abstract][Full Text] [Related]  

  • 19. k-t GRAPPA: a k-space implementation for dynamic MRI with high reduction factor.
    Huang F; Akao J; Vijayakumar S; Duensing GR; Limkeman M
    Magn Reson Med; 2005 Nov; 54(5):1172-84. PubMed ID: 16193468
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion.
    Shin PJ; Larson PE; Ohliger MA; Elad M; Pauly JM; Vigneron DB; Lustig M
    Magn Reson Med; 2014 Oct; 72(4):959-70. PubMed ID: 24248734
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.