These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 21607845)

  • 21. Internal iliac artery coil embolization in the prevention of potential type 2 endoleak after endovascular repair of abdominal aortoiliac and iliac artery aneurysms: effect of total occlusion versus residual flow.
    Heye S; Nevelsteen A; Maleux G
    J Vasc Interv Radiol; 2005 Feb; 16(2 Pt 1):235-9. PubMed ID: 15713924
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Structural limitations of currently available microcatheters and coils for endovascular coiling of very small aneurysms.
    Lim YC; Kim BM; Shin YS; Kim SY; Chung J
    Neuroradiology; 2008 May; 50(5):423-7. PubMed ID: 18283447
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Flow-directed microcatheters for cerebral embolizations using Ethibloc--an in vitro study.
    Doerfler A; Goericke S; Wanke I; Holla M; Forsting M
    Neuroradiology; 2001 Dec; 43(12):1112-7. PubMed ID: 11792056
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Monorail snare technique for the retrieval of an adherent microcatheter from an onyx cast: technical case report.
    Kelly ME; Turner R; Gonugunta V; Rasmussen PA; Woo HH; Fiorella D
    Neurosurgery; 2008 Jul; 63(1 Suppl 1):ONSE89; discussion ONSE89. PubMed ID: 18728613
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Management of visceral artery embolization using 0.010-inch detachable microcoils.
    Koganemaru M; Abe T; Nonoshita M; Iwamoto R; Kusumoto M; Kuhara A; Kugiyama T
    Diagn Interv Radiol; 2014; 20(4):345-8. PubMed ID: 24509180
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Embolization of the gastroduodenal artery before selective internal radiotherapy: a prospectively randomized trial comparing platinum-fibered microcoils with the Amplatzer Vascular Plug II.
    Pech M; Kraetsch A; Wieners G; Redlich U; Gaffke G; Ricke J; Dudeck O
    Cardiovasc Intervent Radiol; 2009 May; 32(3):455-61. PubMed ID: 19137369
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Tailor-made shaping of microcatheters using three-dimensional printed vessel models for endovascular coil embolization.
    Ishibashi T; Takao H; Suzuki T; Yuki I; Kaku S; Kan I; Nishimura K; Suzuki T; Watanabe M; Karagiozov K; Murayama Y
    Comput Biol Med; 2016 Oct; 77():59-63. PubMed ID: 27521515
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Technique for shaping microcatheter tips in coil embolization of paraclinoid aneurysms using full-scale volume rendering images of 3D rotational angiography.
    Toyota S; Fujimoto Y; Iwamoto F; Wakayama A; Yoshimine T
    Minim Invasive Neurosurg; 2009 Aug; 52(4):201-3. PubMed ID: 19838977
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Endovascular catheter for magnetic navigation under MR imaging guidance: evaluation of safety in vivo at 1.5T.
    Hetts SW; Saeed M; Martin AJ; Evans L; Bernhardt AF; Malba V; Settecase F; Do L; Yee EJ; Losey A; Sincic R; Lillaney P; Roy S; Arenson RL; Wilson MW
    AJNR Am J Neuroradiol; 2013; 34(11):2083-91. PubMed ID: 23846795
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Aneurysm coil embolization using a 1.5-fr distal outer diameter microcatheter.
    Stidd DA; Lopes DK; Chen M
    Neurointervention; 2014 Feb; 9(1):39-44. PubMed ID: 24643022
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Mechanical detachable platinum coil: report of the European phase II clinical trial in 60 patients.
    Murphy KJ; Houdart E; Szopinski KT; Levrier O; Guimaraens L; Kühne D; Solymosi L; Bartholdy NJ; Rüfenacht DA
    Radiology; 2001 May; 219(2):541-4. PubMed ID: 11323485
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Distal-tip shape-consistency testing of steam-shaped microcatheters suitable for cerebral aneurysm coil placement.
    Abe T; Hirohata M; Tanaka N; Uchiyama Y; Fujimoto K; Fujimura N; Norbash AM; Hayabuchi N
    AJNR Am J Neuroradiol; 2004; 25(6):1058-61. PubMed ID: 15205148
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Treatment of intracranial broad-neck aneurysms with a new self-expanding stent and coil embolization.
    Alfke K; Straube T; Dörner L; Mehdorn HM; Jansen O
    AJNR Am J Neuroradiol; 2004 Apr; 25(4):584-91. PubMed ID: 15090346
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Type II endoleak prevention with coil embolization during endovascular aneurysm repair in high-risk patients.
    Fabre D; Fadel E; Brenot P; Hamdi S; Gomez Caro A; Mussot S; Becquemin JP; Angel C
    J Vasc Surg; 2015 Jul; 62(1):1-7. PubMed ID: 25937609
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Microcatheter Looping to Facilitate Aneurysm Selection in Coil Embolization of Paraclinoid Aneurysms.
    Cho YD; Rhim JK; Park JJ; Jeon JS; Yoo RE; Kang HS; Kim JE; Cho WS; Han MH
    Korean J Radiol; 2015; 16(4):899-905. PubMed ID: 26175591
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Erosion of Embolization Coils into the Renal Collecting System: Removal with Prone Transradial Renal Arteriography and Nephroscopy.
    Srinivasa RN; Chick JFB; Hage A; Ramamurthi A; Wolf JS; Gemmete JJ; Dauw CA
    J Endourol; 2017 Oct; 31(10):1019-1025. PubMed ID: 28830216
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Double Balloon-Assisted Coil Embolization (BACE) Combined with Proximal and Distal Balloon Inflation for Short Abdominal Arterial Segments: Comparison with Single BACE.
    Maruyama M; Yoshizako T; Nakamura T; Nakamura M; Yoshida R; Ando S; Kitagaki H
    Cardiovasc Intervent Radiol; 2017 Oct; 40(10):1617-1623. PubMed ID: 28593394
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Compact coil packing using a steerable microcatheter for a giant wide-necked pulmonary artery pseudoaneurysm.
    Umakoshi N; Arai Y; Sone M; Sugawara S
    Interact Cardiovasc Thorac Surg; 2019 May; 28(5):826-827. PubMed ID: 30561622
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Coil embolization of a large, wide-necked aneurysm using a double coil-delivered microcatheter technique in combination with a balloon-assisted technique.
    Nakahara T; Kutsuna M; Yamanaka M; Sakoda K
    Neurol Res; 1999 Apr; 21(3):324-6. PubMed ID: 10319344
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Use of a latest-generation vascular plug for peripheral vascular embolization with use of a diagnostic catheter: preliminary clinical experience.
    Mordasini P; Szucs-Farkas Z; Do DD; Gralla J; Kettenbach J; Hoppe H
    J Vasc Interv Radiol; 2010 Aug; 21(8):1185-90. PubMed ID: 20627777
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.