These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
56 related articles for article (PubMed ID: 21610299)
21. Mechanical forces as predictors of healing during tibial lengthening by distraction osteogenesis. Aronson J; Harp JH Clin Orthop Relat Res; 1994 Apr; (301):73-9. PubMed ID: 8156700 [TBL] [Abstract][Full Text] [Related]
22. Monitoring the healing of a tibial osteotomy in the rabbit treated with external fixation. Kaplan SJ; Hayes WC; Mudan P; Lelli JL; White AA J Orthop Res; 1985; 3(3):325-30. PubMed ID: 4032104 [TBL] [Abstract][Full Text] [Related]
23. [Treatment concepts and results in non-infected post-traumatic pseudarthroses of the femur and tibia]. Jürgens C; Wolter D; Queitsch C; Schultz JH Zentralbl Chir; 1994; 119(10):706-13. PubMed ID: 7801709 [TBL] [Abstract][Full Text] [Related]
24. Stiffness measurement of the neocallus with the Fraktometer FM 100. Schmickal T; von Recum J; Wentzensen A Arch Orthop Trauma Surg; 2005 Dec; 125(10):653-9. PubMed ID: 16189688 [TBL] [Abstract][Full Text] [Related]
25. Load transmission through a healing tibial fracture. Vijayakumar V; Marks L; Bremmer-Smith A; Hardy J; Gardner T Clin Biomech (Bristol); 2006 Jan; 21(1):49-53. PubMed ID: 16226358 [TBL] [Abstract][Full Text] [Related]
26. Locally applied nerve growth factor enhances bone consolidation in a rabbit model of mandibular distraction osteogenesis. Wang L; Zhou S; Liu B; Lei D; Zhao Y; Lu C; Tan A J Orthop Res; 2006 Dec; 24(12):2238-45. PubMed ID: 17001706 [TBL] [Abstract][Full Text] [Related]
27. Correlation of pQCT bone strength index with mechanical testing in distraction osteogenesis. Kokoroghiannis C; Charopoulos I; Lyritis G; Raptou P; Karachalios T; Papaioannou N Bone; 2009 Sep; 45(3):512-6. PubMed ID: 19497394 [TBL] [Abstract][Full Text] [Related]
28. The use of a circular external skeletal fixation device for the management of long bone osteotomies in large ruminants: an experimental study. Aithal HP; Singh GR; Hoque M; Maiti SK; Kinjavdekar P; Pawde AM; Setia HC; J Vet Med A Physiol Pathol Clin Med; 2004 Aug; 51(6):284-93. PubMed ID: 15485564 [TBL] [Abstract][Full Text] [Related]
29. Pressure, oxygen tension and temperature in the periosteal callus during bone healing--an in vivo study in sheep. Epari DR; Lienau J; Schell H; Witt F; Duda GN Bone; 2008 Oct; 43(4):734-9. PubMed ID: 18634913 [TBL] [Abstract][Full Text] [Related]
30. Nonunion of the external maxillary distraction in cleft lip and palate: analysis of possible reasons. He D; Genecov DG; Barcelo R J Oral Maxillofac Surg; 2010 Oct; 68(10):2402-11. PubMed ID: 20605305 [TBL] [Abstract][Full Text] [Related]
31. Mid-tibial distraction osteogenesis redistributes bone blood flow: a microsphere study in rabbits. Eckardt H; Lind M; Christensen KS; Hansen ES; Hvid I Acta Orthop; 2005 Aug; 76(4):459-64. PubMed ID: 16195058 [TBL] [Abstract][Full Text] [Related]
32. Quantitative assessment of in vivo bone regeneration consolidation in distraction osteogenesis. Windhagen H; Kolbeck S; Bail H; Schmeling A; Raschke M J Orthop Res; 2000 Nov; 18(6):912-9. PubMed ID: 11192251 [TBL] [Abstract][Full Text] [Related]
33. A new bending stiffness measurement device to monitor the influence of different intramedullar implants during healing period. Thorey F; Richter A; Besdo S; Hackenbroich C; Meyer-Lindenberg A; Hurschler C; Windhagen H Technol Health Care; 2008; 16(2):129-40. PubMed ID: 18487859 [TBL] [Abstract][Full Text] [Related]
34. Intermittent parathyroid hormone (1-34) enhances mechanical strength and density of new bone after distraction osteogenesis in rats. Seebach C; Skripitz R; Andreassen TT; Aspenberg P J Orthop Res; 2004 May; 22(3):472-8. PubMed ID: 15099623 [TBL] [Abstract][Full Text] [Related]
35. Comparison of cyclic compression, cyclic distraction and rigid fixation. Bone healing in rabbits. Matsushita T; Kurokawa T Acta Orthop Scand; 1998 Feb; 69(1):95-8. PubMed ID: 9524527 [TBL] [Abstract][Full Text] [Related]
36. The Use of Distraction Osteogenesis and a Taylor Spatial Frame in the Treatment of a Tibial Shaft Nonunion and Deformity in a Pediatric Patient with Osteopetrosis: A Case Report. Catanzano AA; Fitch RD JBJS Case Connect; 2018; 8(4):e93. PubMed ID: 30489377 [TBL] [Abstract][Full Text] [Related]
37. Decline in transfixing K-wire tension of the circular external fixator: experimental continuous in vivo measurements. Stein H; Perren SM; Mosheiff R; Baumgart F; Cordey J Orthopedics; 2001 Oct; 24(10):985-9. PubMed ID: 11688779 [No Abstract] [Full Text] [Related]
38. [Telemetric transmission system for in vivo measurement of the stress load of an internal spinal fixator]. Graichen F; Bergmann G; Rohlmann A Biomed Tech (Berl); 1994 Oct; 39(10):251-8. PubMed ID: 7811908 [TBL] [Abstract][Full Text] [Related]
39. An electronically instrumented internal fixator for the assessment of bone healing. Kienast B; Kowald B; Seide K; Aljudaibi M; Faschingbauer M; Juergens C; Gille J Bone Joint Res; 2016 May; 5(5):191-7. PubMed ID: 27226357 [TBL] [Abstract][Full Text] [Related]
40. A telemetric system for the strain gauge determination of strain in bone in vivo. Schatzker J; Sumner-Smith G; Hoare J; McBroom R Arch Orthop Trauma Surg (1978); 1980; 96(4):309-11. PubMed ID: 7396679 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]