These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 21611735)

  • 1. Optical waveguides for the evanescent wave-induced cleavage of photolabile linker compounds.
    Schmitt K; Rist J; Hoffmann C
    Anal Bioanal Chem; 2011 Aug; 401(2):777-82. PubMed ID: 21611735
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rapid photochemical surface patterning of proteins in thiol-ene based microfluidic devices.
    Lafleur JP; Kwapiszewski R; Jensen TG; Kutter JP
    Analyst; 2013 Feb; 138(3):845-9. PubMed ID: 23193537
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Direct immobilization of biotin on the micro-patterned PEN foil treated by excimer laser.
    Štofik M; Semerádtová A; Malý J; Kolská Z; Neděla O; Wrobel D; Slepička P
    Colloids Surf B Biointerfaces; 2015 Apr; 128():363-369. PubMed ID: 25771440
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multi-step surface functionalization of polyimide based evanescent wave photonic biosensors and application for DNA hybridization by Mach-Zehnder interferometer.
    Melnik E; Bruck R; Hainberger R; Lämmerhofer M
    Anal Chim Acta; 2011 Aug; 699(2):206-15. PubMed ID: 21704776
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Streptavidin functionalized polymer nanodots fabricated by visible light lithography.
    Wolfesberger C; Wollhofen R; Buchegger B; Jacak J; Klar TA
    J Nanobiotechnology; 2015 Mar; 13():27. PubMed ID: 25888763
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of streptavidins with varying biotin binding affinities on the properties of biotinylated gramicidin channels.
    Antonenko YN; Rokitskaya TI; Kotova EA; Reznik GO; Sano T; Cantor CR
    Biochemistry; 2004 Apr; 43(15):4575-82. PubMed ID: 15078104
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Immobilized streptavidin gradients as bioconjugation platforms.
    Coad BR; Vasilev K; Diener KR; Hayball JD; Short RD; Griesser HJ
    Langmuir; 2012 Feb; 28(5):2710-7. PubMed ID: 22235975
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biotinylated Fluorescent Polymeric Nanoparticles for Enhanced Immunostaining.
    Yudhistira T; Da Silva EC; Combes A; Lehmann M; Reisch A; Klymchenko AS
    Small Methods; 2023 Apr; 7(4):e2201452. PubMed ID: 36808832
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A two-photon excitation fluorescence cross-correlation assay for a model ligand-receptor binding system using quantum dots.
    Swift JL; Heuff R; Cramb DT
    Biophys J; 2006 Feb; 90(4):1396-410. PubMed ID: 16299079
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electrophoretic behavior of streptavidin complexed to a biotinylated probe: a functional screening assay for biotin-binding proteins.
    Humbert N; Zocchi A; Ward TR
    Electrophoresis; 2005 Jan; 26(1):47-52. PubMed ID: 15624156
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optical Detection of Photorelease Kinetics on Gold and Glass Surfaces using Streptavidin-Coupled Biotinylated Photolabile Protecting Groups for Nucleosides.
    Drexler K; Smirnova J; Galetskaya M; Schweizer N; Gauglitz G; Steiner UE
    Chemphyschem; 2017 Oct; 18(20):2890-2898. PubMed ID: 28771905
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Synthesis of hetero-telechelic alpha,omega bio-functionalized polymers.
    Roth PJ; Jochum FD; Zentel R; Theato P
    Biomacromolecules; 2010 Jan; 11(1):238-44. PubMed ID: 19947639
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Imaging and spectroscopic comparison of multi-step methods to form DNA arrays based on the biotin-streptavidin system.
    Gajos K; Petrou P; Budkowski A; Awsiuk K; Bernasik A; Misiakos K; Rysz J; Raptis I; Kakabakos S
    Analyst; 2015 Feb; 140(4):1127-39. PubMed ID: 25535629
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biotinylated non-ionic amphipols for GPCR ligands screening.
    Bosco M; Damian M; Chauhan V; Roche M; Guillet P; Fehrentz JA; Bonneté F; Polidori A; Banères JL; Durand G
    Methods; 2020 Aug; 180():69-78. PubMed ID: 32505829
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Encapsulation of fluorescent molecules by functionalized polymeric nanocontainers: investigation by confocal fluorescence imaging and fluorescence correlation spectroscopy.
    Rigler P; Meier W
    J Am Chem Soc; 2006 Jan; 128(1):367-73. PubMed ID: 16390167
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Synthesis of monodisperse biotinylated p(NIPAAm)-coated iron oxide magnetic nanoparticles and their bioconjugation to streptavidin.
    Narain R; Gonzales M; Hoffman AS; Stayton PS; Krishnan KM
    Langmuir; 2007 May; 23(11):6299-304. PubMed ID: 17451262
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Facile characterization of the immobilization of streptavidin on magnetic submicron particles with a fluorescent probe of streptavidin.
    Long G; Zhang Y; Yang X; Pu J; Qin J; Liu L; Liao F
    Appl Spectrosc; 2013 Jun; 67(6):688-91. PubMed ID: 23735255
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Coupling of biotin-(poly(ethylene glycol))amine to poly(D,L-lactide-co-glycolide) nanoparticles for versatile surface modification.
    Weiss B; Schneider M; Muys L; Taetz S; Neumann D; Schaefer UF; Lehr CM
    Bioconjug Chem; 2007; 18(4):1087-94. PubMed ID: 17590034
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cellular uptake of fluorescent labelled biotin-streptavidin microspheres.
    Bradley M; Alexander L; Sanchez-Martin RM
    J Fluoresc; 2008; 18(3-4):733-9. PubMed ID: 18330682
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Capture and Release of Protein-Nanoparticle Conjugates by Reversible Covalent Molecular Linkers.
    Moran IW; Sprachman MM; Bachman JL; Dahlhauser SD; Anslyn EV; Carter DJD
    Bioconjug Chem; 2020 Sep; 31(9):2191-2200. PubMed ID: 32786373
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.