BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 21613945)

  • 1. Peak insertion torque correlated to histologically and clinically evaluated bone density.
    Makary C; Rebaudi A; Mokbel N; Naaman N
    Implant Dent; 2011 Jun; 20(3):182-91. PubMed ID: 21613945
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implant primary stability determined by resonance frequency analysis: correlation with insertion torque, histologic bone volume, and torsional stability at 6 weeks.
    Makary C; Rebaudi A; Sammartino G; Naaman N
    Implant Dent; 2012 Dec; 21(6):474-80. PubMed ID: 23149504
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical outcome of dental implants placed with high insertion torques (up to 176 Ncm).
    Khayat PG; Arnal HM; Tourbah BI; Sennerby L
    Clin Implant Dent Relat Res; 2013 Apr; 15(2):227-33. PubMed ID: 21599832
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study.
    Alghamdi H; Anand PS; Anil S
    J Oral Maxillofac Surg; 2011 Dec; 69(12):e506-12. PubMed ID: 22117707
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
    Turkyilmaz I; Sennerby L; Yilmaz B; Bilecenoglu B; Ozbek EN
    Clin Implant Dent Relat Res; 2009 Mar; 11(1):52-8. PubMed ID: 18384400
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model.
    Beer A; Gahleitner A; Holm A; Birkfellner W; Homolka P
    Clin Oral Implants Res; 2007 Feb; 18(1):103-7. PubMed ID: 17224030
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Initial torque stability of a new bone condensing dental implant. A cohort study of 140 consecutively placed implants.
    Irinakis T; Wiebe C
    J Oral Implantol; 2009; 35(6):277-82. PubMed ID: 20017643
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Resonance frequency analysis measurements of implants at placement surgery.
    Ostman PO; Hellman M; Wendelhag I; Sennerby L
    Int J Prosthodont; 2006; 19(1):77-83; discussion 84. PubMed ID: 16479765
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of the correlation between insertion torque and resonance frequency analysis of implants placed in bone tissue of different densities.
    Filho LC; Cirano FR; Hayashi F; Feng HS; Conte A; Dib LL; Casati MZ
    J Oral Implantol; 2014 Jun; 40(3):259-62. PubMed ID: 24914911
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A correlation between bone (B), insertion torque (IT), and implant stability (S): BITS score.
    Herekar M; Sethi M; Ahmad T; Fernandes AS; Patil V; Kulkarni H
    J Prosthet Dent; 2014 Oct; 112(4):805-10. PubMed ID: 24726588
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study.
    Ahn SJ; Leesungbok R; Lee SW; Heo YK; Kang KL
    J Prosthet Dent; 2012 Jun; 107(6):366-72. PubMed ID: 22633592
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of drilling dimension on implant placement torque and early osseointegration stages: an experimental study in dogs.
    Campos FE; Gomes JB; Marin C; Teixeira HS; Suzuki M; Witek L; Zanetta-Barbosa D; Coelho PG
    J Oral Maxillofac Surg; 2012 Jan; 70(1):e43-50. PubMed ID: 22182660
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical stability of immediately loaded implants with various surfaces and designs: a pilot study in dogs.
    Neugebauer J; Weinländer M; Lekovic V; von Berg KH; Zoeller JE
    Int J Oral Maxillofac Implants; 2009; 24(6):1083-92. PubMed ID: 20162113
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: a pilot study.
    Fuster-Torres MÁ; Peñarrocha-Diago M; Peñarrocha-Oltra D; Peñarrocha-Diago M
    Int J Oral Maxillofac Implants; 2011; 26(5):1051-6. PubMed ID: 22010089
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites.
    Degidi M; Daprile G; Piattelli A; Carinci F
    Clin Implant Dent Relat Res; 2007 Sep; 9(3):144-9. PubMed ID: 17716258
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Heat generation during implant placement in low-density bone: effect of surgical technique, insertion torque and implant macro design.
    Marković A; Mišić T; Miličić B; Calvo-Guirado JL; Aleksić Z; Ðinić A
    Clin Oral Implants Res; 2013 Jul; 24(7):798-805. PubMed ID: 22469169
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retrospective study of 68 implants placed in the pterygomaxillary region using drills and osteotomes.
    Peñarrocha M; Carrillo C; Boronat A; Peñarrocha M
    Int J Oral Maxillofac Implants; 2009; 24(4):720-6. PubMed ID: 19885414
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study.
    Tabassum A; Meijer GJ; Wolke JG; Jansen JA
    Clin Oral Implants Res; 2009 Apr; 20(4):327-32. PubMed ID: 19298286
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implant micromotion is related to peak insertion torque and bone density.
    Trisi P; Perfetti G; Baldoni E; Berardi D; Colagiovanni M; Scogna G
    Clin Oral Implants Res; 2009 May; 20(5):467-71. PubMed ID: 19522976
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis.
    Falco A; Berardini M; Trisi P
    Int J Oral Maxillofac Implants; 2018; 33(4):824-830. PubMed ID: 30024998
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.