213 related articles for article (PubMed ID: 21613945)
1. Peak insertion torque correlated to histologically and clinically evaluated bone density.
Makary C; Rebaudi A; Mokbel N; Naaman N
Implant Dent; 2011 Jun; 20(3):182-91. PubMed ID: 21613945
[TBL] [Abstract][Full Text] [Related]
2. Implant primary stability determined by resonance frequency analysis: correlation with insertion torque, histologic bone volume, and torsional stability at 6 weeks.
Makary C; Rebaudi A; Sammartino G; Naaman N
Implant Dent; 2012 Dec; 21(6):474-80. PubMed ID: 23149504
[TBL] [Abstract][Full Text] [Related]
3. Clinical outcome of dental implants placed with high insertion torques (up to 176 Ncm).
Khayat PG; Arnal HM; Tourbah BI; Sennerby L
Clin Implant Dent Relat Res; 2013 Apr; 15(2):227-33. PubMed ID: 21599832
[TBL] [Abstract][Full Text] [Related]
4. Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study.
Alghamdi H; Anand PS; Anil S
J Oral Maxillofac Surg; 2011 Dec; 69(12):e506-12. PubMed ID: 22117707
[TBL] [Abstract][Full Text] [Related]
5. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
Turkyilmaz I; Sennerby L; Yilmaz B; Bilecenoglu B; Ozbek EN
Clin Implant Dent Relat Res; 2009 Mar; 11(1):52-8. PubMed ID: 18384400
[TBL] [Abstract][Full Text] [Related]
6. Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model.
Beer A; Gahleitner A; Holm A; Birkfellner W; Homolka P
Clin Oral Implants Res; 2007 Feb; 18(1):103-7. PubMed ID: 17224030
[TBL] [Abstract][Full Text] [Related]
7. Initial torque stability of a new bone condensing dental implant. A cohort study of 140 consecutively placed implants.
Irinakis T; Wiebe C
J Oral Implantol; 2009; 35(6):277-82. PubMed ID: 20017643
[TBL] [Abstract][Full Text] [Related]
8. Resonance frequency analysis measurements of implants at placement surgery.
Ostman PO; Hellman M; Wendelhag I; Sennerby L
Int J Prosthodont; 2006; 19(1):77-83; discussion 84. PubMed ID: 16479765
[TBL] [Abstract][Full Text] [Related]
9. Assessment of the correlation between insertion torque and resonance frequency analysis of implants placed in bone tissue of different densities.
Filho LC; Cirano FR; Hayashi F; Feng HS; Conte A; Dib LL; Casati MZ
J Oral Implantol; 2014 Jun; 40(3):259-62. PubMed ID: 24914911
[TBL] [Abstract][Full Text] [Related]
10. A correlation between bone (B), insertion torque (IT), and implant stability (S): BITS score.
Herekar M; Sethi M; Ahmad T; Fernandes AS; Patil V; Kulkarni H
J Prosthet Dent; 2014 Oct; 112(4):805-10. PubMed ID: 24726588
[TBL] [Abstract][Full Text] [Related]
11. Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study.
Ahn SJ; Leesungbok R; Lee SW; Heo YK; Kang KL
J Prosthet Dent; 2012 Jun; 107(6):366-72. PubMed ID: 22633592
[TBL] [Abstract][Full Text] [Related]
12. Effect of drilling dimension on implant placement torque and early osseointegration stages: an experimental study in dogs.
Campos FE; Gomes JB; Marin C; Teixeira HS; Suzuki M; Witek L; Zanetta-Barbosa D; Coelho PG
J Oral Maxillofac Surg; 2012 Jan; 70(1):e43-50. PubMed ID: 22182660
[TBL] [Abstract][Full Text] [Related]
13. Mechanical stability of immediately loaded implants with various surfaces and designs: a pilot study in dogs.
Neugebauer J; Weinländer M; Lekovic V; von Berg KH; Zoeller JE
Int J Oral Maxillofac Implants; 2009; 24(6):1083-92. PubMed ID: 20162113
[TBL] [Abstract][Full Text] [Related]
14. Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: a pilot study.
Fuster-Torres MÁ; Peñarrocha-Diago M; Peñarrocha-Oltra D; Peñarrocha-Diago M
Int J Oral Maxillofac Implants; 2011; 26(5):1051-6. PubMed ID: 22010089
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites.
Degidi M; Daprile G; Piattelli A; Carinci F
Clin Implant Dent Relat Res; 2007 Sep; 9(3):144-9. PubMed ID: 17716258
[TBL] [Abstract][Full Text] [Related]
16. Heat generation during implant placement in low-density bone: effect of surgical technique, insertion torque and implant macro design.
Marković A; Mišić T; Miličić B; Calvo-Guirado JL; Aleksić Z; Ðinić A
Clin Oral Implants Res; 2013 Jul; 24(7):798-805. PubMed ID: 22469169
[TBL] [Abstract][Full Text] [Related]
17. Retrospective study of 68 implants placed in the pterygomaxillary region using drills and osteotomes.
Peñarrocha M; Carrillo C; Boronat A; Peñarrocha M
Int J Oral Maxillofac Implants; 2009; 24(4):720-6. PubMed ID: 19885414
[TBL] [Abstract][Full Text] [Related]
18. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study.
Tabassum A; Meijer GJ; Wolke JG; Jansen JA
Clin Oral Implants Res; 2009 Apr; 20(4):327-32. PubMed ID: 19298286
[TBL] [Abstract][Full Text] [Related]
19. Implant micromotion is related to peak insertion torque and bone density.
Trisi P; Perfetti G; Baldoni E; Berardi D; Colagiovanni M; Scogna G
Clin Oral Implants Res; 2009 May; 20(5):467-71. PubMed ID: 19522976
[TBL] [Abstract][Full Text] [Related]
20. Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis.
Falco A; Berardini M; Trisi P
Int J Oral Maxillofac Implants; 2018; 33(4):824-830. PubMed ID: 30024998
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]