730 related articles for article (PubMed ID: 21613946)
1. Evaluation of bone insertion level of support teeth in class I mandibular removable partial denture associated with an osseointegrated implant: a study using finite element analysis.
Verri FR; Pellizzer EP; Pereira JA; Zuim PR; Santiago Júnior JF
Implant Dent; 2011 Jun; 20(3):192-201. PubMed ID: 21613946
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of the influence of location of osseointegrated implants associated with mandibular removable partial dentures.
Cunha LD; Pellizzer EP; Verri FR; Pereira JA
Implant Dent; 2008 Sep; 17(3):278-87. PubMed ID: 18784528
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of different retention systems on a distal extension removable partial denture associated with an osseointegrated implant.
Pellizzer EP; Verri FR; Falcón-Antenucci RM; Goiato MC; Gennari Filho H
J Craniofac Surg; 2010 May; 21(3):727-34. PubMed ID: 20485037
[TBL] [Abstract][Full Text] [Related]
4. Influence of implant inclination associated with mandibular class I removable partial denture.
de Freitas Santos CM; Pellizzer EP; Verri FR; de Moraes SL; Falcón-Antenucci RM
J Craniofac Surg; 2011 Mar; 22(2):663-8. PubMed ID: 21415633
[TBL] [Abstract][Full Text] [Related]
5. Influence of length and diameter of implants associated with distal extension removable partial dentures.
Verri FR; Pellizzer EP; Rocha EP; Pereira JA
Implant Dent; 2007 Sep; 16(3):270-80. PubMed ID: 17846543
[TBL] [Abstract][Full Text] [Related]
6. Influence of ridge inclination and implant localization on the association of mandibular Kennedy class I removable partial denture.
Cunha LD; Pellizzer EP; Verri FR; Falcón-Antenucci RM; Goiato MC
J Craniofac Surg; 2011 May; 22(3):871-5. PubMed ID: 21558932
[TBL] [Abstract][Full Text] [Related]
7. Finite element analysis of an implant-assisted removable partial denture during bilateral loading: occlusal rests position.
Shahmiri R; Das R; Aarts JM; Bennani V
J Prosthet Dent; 2014 Nov; 112(5):1126-33. PubMed ID: 24951387
[TBL] [Abstract][Full Text] [Related]
8. Finite element method analysis of stress distribution to supporting tissues in a Class IV Aramany removable partial denture (Part II: bone and mucosal membrane).
Gharechahi J; Sharifi E; Nosohian S; Aghdaee NA
J Contemp Dent Pract; 2008 Nov; 9(7):49-56. PubMed ID: 18997916
[TBL] [Abstract][Full Text] [Related]
9. Effects of rigid and nonrigid extracoronal attachments on supporting tissues in extension base partial removable dental prostheses: a nonlinear finite element study.
Wang HY; Zhang YM; Yao D; Chen JH
J Prosthet Dent; 2011 May; 105(5):338-46. PubMed ID: 21530760
[TBL] [Abstract][Full Text] [Related]
10. Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures.
Tanino F; Hayakawa I; Hirano S; Minakuchi S
Int J Prosthodont; 2007; 20(2):193-8. PubMed ID: 17455444
[TBL] [Abstract][Full Text] [Related]
11. Finite element method analysis of the stress distribution to supporting tissues in a Class IV Aramany removable partial denture (Part I: the teeth and periodontal ligament).
Gharechahi J; Sharifi E; Aghdaee NA; Nosohian S
J Contemp Dent Pract; 2008 Sep; 9(6):65-72. PubMed ID: 18784861
[TBL] [Abstract][Full Text] [Related]
12. Removable dentures with implant support in strategic positions followed for up to 8 years.
Kaufmann R; Friedli M; Hug S; Mericske-Stern R
Int J Prosthodont; 2009; 22(3):233-41; discussion 242. PubMed ID: 19548404
[TBL] [Abstract][Full Text] [Related]
13. The influence of the alveolar ridge shape on the stress distribution in a free-end saddle removable partial denture supported by implant.
Júnior MM; Anchieta RB; Rocha EP; Pereira JA; Archangelo CM; Freitas-Júnior AC; Almeida EO
Acta Odontol Latinoam; 2011; 24(2):168-75. PubMed ID: 22165315
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysis.
Lin CL; Wang JC; Chang WJ
Clin Oral Implants Res; 2008 Jan; 19(1):107-17. PubMed ID: 17944965
[TBL] [Abstract][Full Text] [Related]
15. Finite element contact stress analysis of the RPD abutment tooth and periodontal ligament.
Muraki H; Wakabayashi N; Park I; Ohyama T
J Dent; 2004 Nov; 32(8):659-65. PubMed ID: 15476961
[TBL] [Abstract][Full Text] [Related]
16. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.
Merıç G; Erkmen E; Kurt A; Eser A; özden AU
Acta Odontol Scand; 2011 Nov; 69(6):374-84. PubMed ID: 21449688
[TBL] [Abstract][Full Text] [Related]
17. Biomechanical behaviour of tooth-supported fixed partial dentures by 3D FEA.
Naveau A; Chesneau J; Barquins M; Pierrisnard L
Eur J Prosthodont Restor Dent; 2009 Dec; 17(4):157-63. PubMed ID: 20158056
[TBL] [Abstract][Full Text] [Related]
18. Three-dimensional stress analysis of tooth/lmplant-retained long-span fixed dentures.
Maezawa N; Shiota M; Kasugai S; Wakabayashi N
Int J Oral Maxillofac Implants; 2007; 22(5):710-8. PubMed ID: 17974104
[TBL] [Abstract][Full Text] [Related]
19. The effect of implant design on the stress distribution in a three-unit implant-supported distal cantilever fixed partial denture: a three-dimensional finite-element analysis.
Koka P; Mohapatra A; Anandapandian PA; Murugesan K; Vasanthakumar M
Indian J Dent Res; 2012; 23(2):129-34. PubMed ID: 22945697
[TBL] [Abstract][Full Text] [Related]
20. Platform switching: biomechanical evaluation using three-dimensional finite element analysis.
Tabata LF; Rocha EP; Barão VA; Assunção WG
Int J Oral Maxillofac Implants; 2011; 26(3):482-91. PubMed ID: 21691594
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]