These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
109 related articles for article (PubMed ID: 21619239)
1. Enhanced Serum Carbon Dioxide Measurements with a Silicone Rubber-Based Carbonate Ion-Selective Electrode and a High-pH Dilution Buffer. Shin JH; Sakong DS; Nam H; Cha GS Anal Chem; 1996 Jan; 68(1):221-5. PubMed ID: 21619239 [TBL] [Abstract][Full Text] [Related]
2. One-component room temperature vulcanizing-type silicone rubber-based calcium-selective electrodes. Oh BK; Kim CY; Lee HJ; Rho KL; Cha GS; Nam H Anal Chem; 1996 Feb; 68(3):503-8. PubMed ID: 21619086 [TBL] [Abstract][Full Text] [Related]
3. A lipophilic sol-gel matrix for the development of a carbonate-selective electrode. Lee BH; Shim YB; Park SB Anal Chem; 2004 Oct; 76(20):6150-5. PubMed ID: 15481966 [TBL] [Abstract][Full Text] [Related]
4. Direct optical carbon dioxide sensing based on a polymeric film doped with a selective molecular tweezer-type ionophore. Xie X; Pawlak M; Tercier-Waeber ML; Bakker E Anal Chem; 2012 Apr; 84(7):3163-9. PubMed ID: 22369632 [TBL] [Abstract][Full Text] [Related]
5. Determination of water uptake of polymeric ion-selective membranes with the coulometric Karl Fischer and FT-IR-attenuated total reflection techniques. He N; Lindfors T Anal Chem; 2013 Jan; 85(2):1006-12. PubMed ID: 23249325 [TBL] [Abstract][Full Text] [Related]
6. An all-solid-state reference electrode based on the layer-by-layer polymer coating. Kwon NH; Lee KS; Won MS; Shim YB Analyst; 2007 Sep; 132(9):906-12. PubMed ID: 17710266 [TBL] [Abstract][Full Text] [Related]
7. A cerium(III) selective polyvinyl chloride membrane sensor based on a Schiff base complex of N,N'-bis[2-(salicylideneamino)ethyl]ethane-1,2-diamine. Gupta VK; Singh AK; Gupta B Anal Chim Acta; 2006 Aug; 575(2):198-204. PubMed ID: 17723591 [TBL] [Abstract][Full Text] [Related]
8. Determination of oceanic carbon dioxide using a carbonate-selective electrode. Choi YS; Lvova L; Shin JH; Oh SH; Lee CS; Kim BH; Cha GS; Nam H Anal Chem; 2002 May; 74(10):2435-40. PubMed ID: 12038772 [TBL] [Abstract][Full Text] [Related]
9. Organic tin compounds combined with anionic additives-an ionophore system leading to a phosphate ion-selective electrode? Sasaki S; Ozawa S; Citterio D; Yamada K; Suzuki K Talanta; 2004 May; 63(1):131-4. PubMed ID: 18969410 [TBL] [Abstract][Full Text] [Related]
10. Multiplexed all-solid-state ion-sensitive light-addressable potentiometric sensor (ISLAPS) system based on silicone-rubber for physiological ions detection. Liang T; Jiang N; Zhou S; Wang X; Xu Y; Wu C; Kirsanov D; Legin A; Wan H; Wang P Anal Chim Acta; 2021 Sep; 1179():338603. PubMed ID: 34535249 [TBL] [Abstract][Full Text] [Related]
11. FTIR-ATR study of water uptake and diffusion through ion-selective membranes based on poly(acrylates) and silicone rubber. Sundfors F; Lindfors T; Höfler L; Bereczki R; Gyurcsányi RE Anal Chem; 2009 Jul; 81(14):5925-34. PubMed ID: 19527006 [TBL] [Abstract][Full Text] [Related]
12. PVC-Based Ion-Selective Electrodes with a Silicone Rubber Outer Coating with Improved Analytical Performance. Joon NK; He N; Ruzgas T; Bobacka J; Lisak G Anal Chem; 2019 Aug; 91(16):10524-10531. PubMed ID: 31333015 [TBL] [Abstract][Full Text] [Related]