These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
205 related articles for article (PubMed ID: 21626947)
21. Spectral discrimination of Cerenkov radiation in scintillating dosimeters. Frelin AM; Fontbonne JM; Ban G; Colin J; Labalme M; Batalla A; Isambert A; Vela A; Leroux T Med Phys; 2005 Sep; 32(9):3000-6. PubMed ID: 16266114 [TBL] [Abstract][Full Text] [Related]
22. WE-G-BRB-04: BEST IN PHYSICS (THERAPY) - A Novel Multi-Point Plastic Scintillation Detector for in Vivo Dosimetry and Quality Assurance in Radiation Therapy. Therriault-Proulx F; Beaulieu L; Archambault L; Beddar S Med Phys; 2012 Jun; 39(6Part28):3967. PubMed ID: 28519652 [TBL] [Abstract][Full Text] [Related]
23. Projection imaging of photon beams by the Čerenkov effect. Glaser AK; Davis SC; McClatchy DM; Zhang R; Pogue BW; Gladstone DJ Med Phys; 2013 Jan; 40(1):012101. PubMed ID: 23298103 [TBL] [Abstract][Full Text] [Related]
24. Fabrication and characterization of a stemless plastic scintillation detector. Hupman MA; Monajemi T; Valitova I; Hill IG; Syme A Med Phys; 2020 Nov; 47(11):5882-5889. PubMed ID: 32966652 [TBL] [Abstract][Full Text] [Related]
25. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging. Nillius P; Klamra W; Sibczynski P; Sharma D; Danielsson M; Badano A Med Phys; 2015 Feb; 42(2):600-605. PubMed ID: 28102604 [TBL] [Abstract][Full Text] [Related]
26. Effect of Magnetic Field Strength on Plastic Scintillation Detector Response. Therriault-Proulx F; Wen Z; Ibbott G; Beddar S Radiat Meas; 2018 Sep; 116():10-13. PubMed ID: 30559600 [TBL] [Abstract][Full Text] [Related]
27. Energy dependence of a scintillating fiber detector for preclinical dosimetry with an image guided micro-irradiator. Le Deroff C; Frelin AM; Ledoux X Phys Med Biol; 2019 May; 64(11):115015. PubMed ID: 30974415 [TBL] [Abstract][Full Text] [Related]
28. CALCULATION OF GAMMA SPECTRA IN A PLASTIC SCINTILLATOR FOR ENERGY CALIBRATIONAND DOSE COMPUTATION. Kim C; Yoo H; Kim Y; Moon M; Kim JY; Kang DU; Lee D; Kim MS; Cho M; Lee E; Cho G Radiat Prot Dosimetry; 2016 Sep; 170(1-4):377-81. PubMed ID: 27127208 [TBL] [Abstract][Full Text] [Related]
29. External beam irradiation angle measurement using a hybrid Cerenkov-scintillation detector. Jean E; Lambert-Girard S; Therriault-Proulx F; Beaulieu L Phys Med Biol; 2022 May; 67(10):. PubMed ID: 35483351 [No Abstract] [Full Text] [Related]
30. A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector. Therriault-Proulx F; Wootton L; Beddar S Phys Med Biol; 2015 Oct; 60(20):7927-39. PubMed ID: 26407188 [TBL] [Abstract][Full Text] [Related]
31. Accurate calibration of a polymer gel dosimeter with a plastic scintillation detector. Tremblay NM; Hubert-Tremblay V; Bujold R; Beddar AS; Beaulieu L; Lepage M Med Phys; 2011 May; 38(5):2754-61. PubMed ID: 21776812 [TBL] [Abstract][Full Text] [Related]
32. Measurement accuracy and cerenkov removal for high performance, high spatial resolution scintillation dosimetry. Archambault L; Beddar AS; Gingras L; Roy R; Beaulieu L Med Phys; 2006 Jan; 33(1):128-35. PubMed ID: 16485419 [TBL] [Abstract][Full Text] [Related]
33. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy. Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803 [TBL] [Abstract][Full Text] [Related]
34. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance. Gagnon JC; Thériault D; Guillot M; Archambault L; Beddar S; Gingras L; Beaulieu L Med Phys; 2012 Jan; 39(1):429-36. PubMed ID: 22225313 [TBL] [Abstract][Full Text] [Related]
35. Technical note: characterization of spectral changes with measurement geometry and magnetic field strength in light guides used for scintillation dosimetry. Simiele E; Kapsch RP; Ankerhold U; Culberson W; DeWerd L Phys Med Biol; 2020 Jun; 65(11):11NT01. PubMed ID: 32311693 [TBL] [Abstract][Full Text] [Related]
36. Development of a wavelength-separated type scintillator with optical fiber (SOF) dosimeter to compensate for the Cerenkov radiation effect. Ishikawa M; Nagase N; Matsuura T; Hiratsuka J; Suzuki R; Miyamoto N; Sutherland KL; Fujita K; Shirato H J Radiat Res; 2015 Mar; 56(2):372-81. PubMed ID: 25618136 [TBL] [Abstract][Full Text] [Related]
37. Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide. Lambert J; Yin Y; McKenzie DR; Law S; Suchowerska N Phys Med Biol; 2008 Jun; 53(11):3071-80. PubMed ID: 18490811 [TBL] [Abstract][Full Text] [Related]
38. Cerenkov light spectrum in an optical fiber exposed to a photon or electron radiation therapy beam. Lambert J; Yin Y; McKenzie DR; Law S; Suchowerska N Appl Opt; 2009 Jun; 48(18):3362-7. PubMed ID: 19543342 [TBL] [Abstract][Full Text] [Related]
39. Characterization of the plastic scintillation detector Exradin W2 for small field dosimetry. Galavis PE; Hu L; Holmes S; Das IJ Med Phys; 2019 May; 46(5):2468-2476. PubMed ID: 30897221 [TBL] [Abstract][Full Text] [Related]
40. Determination of the quenching correction factors for plastic scintillation detectors in therapeutic high-energy proton beams. Wang LL; Perles LA; Archambault L; Sahoo N; Mirkovic D; Beddar S Phys Med Biol; 2012 Dec; 57(23):7767-81. PubMed ID: 23128412 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]