162 related articles for article (PubMed ID: 21626951)
1. Technical note: removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: a relevant and necessary step.
Therriault-Proulx F; Beddar S; Briere TM; Archambault L; Beaulieu L
Med Phys; 2011 Apr; 38(4):2176-9. PubMed ID: 21626951
[TBL] [Abstract][Full Text] [Related]
2. A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy.
Therriault-Proulx F; Briere TM; Mourtada F; Aubin S; Beddar S; Beaulieu L
Med Phys; 2011 May; 38(5):2542-51. PubMed ID: 21776789
[TBL] [Abstract][Full Text] [Related]
3. On the use of a single-fiber multipoint plastic scintillation detector for 192Ir high-dose-rate brachytherapy.
Therriault-Proulx F; Beddar S; Beaulieu L
Med Phys; 2013 Jun; 40(6):062101. PubMed ID: 23718599
[TBL] [Abstract][Full Text] [Related]
4. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
[TBL] [Abstract][Full Text] [Related]
5. Inorganic scintillation detectors for
Kertzscher G; Beddar S
Phys Med Biol; 2019 Nov; 64(22):225018. PubMed ID: 31491777
[TBL] [Abstract][Full Text] [Related]
6. Inorganic scintillation detectors based on Eu-activated phosphors for
Kertzscher G; Beddar S
Phys Med Biol; 2017 Jun; 62(12):5046-5075. PubMed ID: 28475494
[TBL] [Abstract][Full Text] [Related]
7. Dosimetric performance of a multipoint plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate
Linares Rosales HM; Archambault L; Beddar S; Beaulieu L
Med Phys; 2020 Sep; 47(9):4477-4490. PubMed ID: 32443175
[TBL] [Abstract][Full Text] [Related]
8. In vivo dosimeters for HDR brachytherapy: a comparison of a diamond detector, MOSFET, TLD, and scintillation detector.
Lambert J; Nakano T; Law S; Elsey J; McKenzie DR; Suchowerska N
Med Phys; 2007 May; 34(5):1759-65. PubMed ID: 17555257
[TBL] [Abstract][Full Text] [Related]
9. The mean photon energy ĒF at the point of measurement determines the detector-specific radiation quality correction factor kQ,M in (192)Ir brachytherapy dosimetry.
Chofor N; Harder D; Selbach HJ; Poppe B
Z Med Phys; 2016 Sep; 26(3):238-50. PubMed ID: 26387927
[TBL] [Abstract][Full Text] [Related]
10. Use of water-equivalent plastic scintillator for intravascular brachytherapy dosimetry.
Geso M; Robinson N; Schumer W; Williams K
Australas Phys Eng Sci Med; 2004 Mar; 27(1):5-10. PubMed ID: 15156701
[TBL] [Abstract][Full Text] [Related]
11. A plastic scintillation dosimeter for high dose rate brachytherapy.
Lambert J; McKenzie DR; Law S; Elsey J; Suchowerska N
Phys Med Biol; 2006 Nov; 51(21):5505-16. PubMed ID: 17047266
[TBL] [Abstract][Full Text] [Related]
12. Development and implementation of a remote audit tool for high dose rate (HDR) Ir-192 brachytherapy using optically stimulated luminescence dosimetry.
Casey KE; Alvarez P; Kry SF; Howell RM; Lawyer A; Followill D
Med Phys; 2013 Nov; 40(11):112102. PubMed ID: 24320455
[TBL] [Abstract][Full Text] [Related]
13. Monte Carlo characterization of high atomic number inorganic scintillators for in vivo dosimetry in
Kaveckyte V; Jørgensen EB; Kertzscher G; Johansen JG; Carlsson Tedgren Å
Med Phys; 2022 Jul; 49(7):4715-4730. PubMed ID: 35443079
[TBL] [Abstract][Full Text] [Related]
14. Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate
Kaveckyte V; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
Med Phys; 2018 Jan; 45(1):429-437. PubMed ID: 29171060
[TBL] [Abstract][Full Text] [Related]
15. 3D source tracking and error detection in HDR using two independent scintillator dosimetry systems.
Linares Rosales HM; Johansen JG; Kertzscher G; Tanderup K; Beaulieu L; Beddar S
Med Phys; 2021 May; 48(5):2095-2107. PubMed ID: 33222208
[TBL] [Abstract][Full Text] [Related]
16. Ruby-based inorganic scintillation detectors for
Kertzscher G; Beddar S
Phys Med Biol; 2016 Nov; 61(21):7744-7764. PubMed ID: 27740947
[TBL] [Abstract][Full Text] [Related]
17. High resolution small-scale inorganic scintillator detector: HDR brachytherapy application.
Debnath SBC; Ferre M; Tonneau D; Fauquet C; Tallet A; Goncalves A; Darreon J
Med Phys; 2021 Apr; 48(4):1485-1496. PubMed ID: 33476399
[TBL] [Abstract][Full Text] [Related]
18. Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.
Lessard F; Archambault L; Plamondon M; Despres P; Therriault-Proulx F; Beddar S; Beaulieu L
Med Phys; 2012 Sep; 39(9):5308-16. PubMed ID: 22957599
[TBL] [Abstract][Full Text] [Related]
19. Direct measurement of instantaneous source speed for a HDR brachytherapy unit using an optical fiber based detector.
Minamisawa RA; Rubo RA; Seraide RM; Rocha JR; Almeida A
Med Phys; 2010 Oct; 37(10):5407-11. PubMed ID: 21089776
[TBL] [Abstract][Full Text] [Related]
20. The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.
Espinoza A; Beeksma B; Petasecca M; Fuduli I; Porumb C; Cutajar D; Corde S; Jackson M; Lerch ML; Rosenfeld AB
Med Phys; 2013 Nov; 40(11):111702. PubMed ID: 24320410
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]