These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
95 related articles for article (PubMed ID: 21626960)
1. Independent quality assurance of a helical tomotherapy machine using the dose magnifying glass. Wong JH; Hardcastle N; Tomé WA; Bayliss A; Tolakanahalli R; Lerch ML; Petasecca M; Carolan M; Metcalfe P; Rosenfeld AB Med Phys; 2011 Apr; 38(4):2256-64. PubMed ID: 21626960 [TBL] [Abstract][Full Text] [Related]
2. A silicon strip detector dose magnifying glass for IMRT dosimetry. Wong JH; Carolan M; Lerch ML; Petasecca M; Khanna S; Perevertaylo VL; Metcalfe P; Rosenfeld AB Med Phys; 2010 Feb; 37(2):427-39. PubMed ID: 20229851 [TBL] [Abstract][Full Text] [Related]
3. The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry. Wong JH; Knittel T; Downes S; Carolan M; Lerch ML; Petasecca M; Perevertaylo VL; Metcalfe P; Jackson M; Rosenfeld AB Med Phys; 2011 Mar; 38(3):1226-38. PubMed ID: 21520835 [TBL] [Abstract][Full Text] [Related]
4. Phantomless patient-specific TomoTherapy QA via delivery performance monitoring and a secondary Monte Carlo dose calculation. Handsfield LL; Jones R; Wilson DD; Siebers JV; Read PW; Chen Q Med Phys; 2014 Oct; 41(10):101703. PubMed ID: 25281942 [TBL] [Abstract][Full Text] [Related]
5. Verification of helical tomotherapy delivery using autoassociative kernel regression. Seibert RM; Ramsey CR; Garvey DR; Hines JW; Robison BH; Outten SS Med Phys; 2007 Aug; 34(8):3249-62. PubMed ID: 17879788 [TBL] [Abstract][Full Text] [Related]
6. Clinical implementation of an exit detector-based dose reconstruction tool for helical tomotherapy delivery quality assurance. Deshpande S; Xing A; Metcalfe P; Holloway L; Vial P; Geurts M Med Phys; 2017 Oct; 44(10):5457-5466. PubMed ID: 28737014 [TBL] [Abstract][Full Text] [Related]
7. Filmless methods for quality assurance of Tomotherapy using ArcCHECK. Yang B; Wong WK; Geng H; Lam WW; Ho YW; Kwok WM; Cheung KY; Yu SK Med Phys; 2017 Jan; 44(1):7-16. PubMed ID: 28044341 [TBL] [Abstract][Full Text] [Related]
8. A diagnostic tool for basic daily quality assurance of a Tomotherapy Hi*Art machine. de Vondel IV; Tournel K; Verellen D; Duchateau M; Lelie S; Storme G J Appl Clin Med Phys; 2009 Oct; 10(4):151-164. PubMed ID: 19918225 [TBL] [Abstract][Full Text] [Related]
9. Quality assurance of the multileaf collimator with helical tomotherapy: design and implementation. Sarkar V; Lin L; Shi C; Papanikolaou N Med Phys; 2007 Jul; 34(7):2949-56. PubMed ID: 17822003 [TBL] [Abstract][Full Text] [Related]
10. Results of a two-year quality control program for a helical tomotherapy unit. Broggi S; Cattaneo GM; Molinelli S; Maggiulli E; Del Vecchio A; Longobardi B; Perna L; Fazio F; Calandrino R Radiother Oncol; 2008 Feb; 86(2):231-41. PubMed ID: 18061691 [TBL] [Abstract][Full Text] [Related]
11. TomoTherapy MLC verification using exit detector data. Chen Q; Westerly D; Fang Z; Sheng K; Chen Y Med Phys; 2012 Jan; 39(1):143-51. PubMed ID: 22225283 [TBL] [Abstract][Full Text] [Related]
12. Monte Carlo calculation of helical tomotherapy dose delivery. Zhao YL; Mackenzie M; Kirkby C; Fallone BG Med Phys; 2008 Aug; 35(8):3491-500. PubMed ID: 18777909 [TBL] [Abstract][Full Text] [Related]
13. A topographic leaf-sequencing algorithm for delivering intensity modulated radiation therapy. Desai D; Ramsey CR; Breinig M; Mahan SL Med Phys; 2006 Aug; 33(8):2751-6. PubMed ID: 16964850 [TBL] [Abstract][Full Text] [Related]
14. In air and in vivo measurement of the leaf open time in tomotherapy using the on-board detector pulse-by-pulse data. Schopfer M; Bochud FO; Bourhis J; Moeckli R Med Phys; 2019 May; 46(5):1963-1971. PubMed ID: 30810233 [TBL] [Abstract][Full Text] [Related]
15. Fast radiographic film calibration procedure for helical tomotherapy intensity modulated radiation therapy dose verification. Yan Y; Papanikolaou N; Weng X; Penagaricano J; Ratanatharathorn V Med Phys; 2005 Jun; 32(6):1566-70. PubMed ID: 16013715 [TBL] [Abstract][Full Text] [Related]
16. Using the volumetric effect of a finite-sized detector for routine quality assurance of multileaf collimator leaf positioning. Yang Y; Xing L Med Phys; 2003 Mar; 30(3):433-41. PubMed ID: 12674244 [TBL] [Abstract][Full Text] [Related]
17. A novel method for routine quality assurance of volumetric-modulated arc therapy. Wang Q; Dai J; Zhang K Med Phys; 2013 Oct; 40(10):101712. PubMed ID: 24089902 [TBL] [Abstract][Full Text] [Related]
18. Dosimetric quality assurance for intensity-modulated radiotherapy feasibility study for a filmless approach. Wiezorek T; Banz N; Schwedas M; Scheithauer M; Salz H; Georg D; Wendt TG Strahlenther Onkol; 2005 Jul; 181(7):468-74. PubMed ID: 15995841 [TBL] [Abstract][Full Text] [Related]
19. Commissioning and quality assurance for MLC-based IMRT. Saw CB; Ayyangar KM; Zhen W; Thompson RB; Enke CA Med Dosim; 2001; 26(2):125-33. PubMed ID: 11444514 [TBL] [Abstract][Full Text] [Related]
20. Enhanced efficiency in helical tomotherapy quality assurance using a custom-designed water-equivalent phantom. Goddu SM; Mutic S; Pechenaya OL; Chaudhari SR; Garcia-Ramirez J; Rangaraj D; Klein EE; Yang D; Grigsby J; Low DA Phys Med Biol; 2009 Oct; 54(19):5663-74. PubMed ID: 19724101 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]