These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 21627576)

  • 21. Comparison of a disposable bougie versus a newly designed malleable bougie in the intubation of a difficult manikin airway.
    Boedeker BH; Bernhagen M; Miller DJ; Murray WB
    Stud Health Technol Inform; 2011; 163():65-7. PubMed ID: 21335760
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Comparison of performance of endotracheal intubation by senior residents in anesthesiology using Airway Scope VS Macintosh laryngoscope].
    Hakozaki T; Hirabayashi Y; Seo N
    Masui; 2009 Jan; 58(1):100-2. PubMed ID: 19175024
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Videolaryngoscopy for endotracheal intubation - new developments in difficult airway management].
    Wasem S; Roewer N; Lange M
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2009 Jul; 44(7-8):502-8. PubMed ID: 19629911
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The Flex-It stylet is less effective than a malleable stylet for orotracheal intubation using the GlideScope.
    Turkstra TP; Jones PM; Ower KM; Gros ML
    Anesth Analg; 2009 Dec; 109(6):1856-9. PubMed ID: 19923515
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The use of Airtraq videolaryngoscope for endotracheal intubation in Intensive Care Unit.
    Corso RM; Piraccini E; Terzitta M; Agnoletti V; Gambale G
    Minerva Anestesiol; 2010 Dec; 76(12):1095-6. PubMed ID: 20592674
    [No Abstract]   [Full Text] [Related]  

  • 26. Effect of just-in-time simulation training on tracheal intubation procedure safety in the pediatric intensive care unit.
    Nishisaki A; Donoghue AJ; Colborn S; Watson C; Meyer A; Brown CA; Helfaer MA; Walls RM; Nadkarni VM
    Anesthesiology; 2010 Jul; 113(1):214-23. PubMed ID: 20526179
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The use of the BERCI DCI Video Laryngoscope for teaching novices direct laryngoscopy and tracheal intubation.
    Low D; Healy D; Rasburn N
    Anaesthesia; 2008 Feb; 63(2):195-201. PubMed ID: 18211452
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A comparison of GlideScope video laryngoscopy versus direct laryngoscopy intubation in the emergency department.
    Platts-Mills TF; Campagne D; Chinnock B; Snowden B; Glickman LT; Hendey GW
    Acad Emerg Med; 2009 Sep; 16(9):866-71. PubMed ID: 19664096
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope.
    Serocki G; Bein B; Scholz J; Dörges V
    Eur J Anaesthesiol; 2010 Jan; 27(1):24-30. PubMed ID: 19809328
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The Parker Flex-Tip tube is useful for Airway Scope-assisted intubation.
    Kitagawa H; Imashuku Y; Yamazaki T
    J Clin Anesth; 2010 Jun; 22(4):307. PubMed ID: 20522368
    [No Abstract]   [Full Text] [Related]  

  • 31. Clinical comparison of two stylet angles for orotracheal intubation with the GlideScope video laryngoscope.
    Dupanović M; Isaacson SA; Borovcanin Z; Jain S; Korten S; Karan S; Messing SP
    J Clin Anesth; 2010 Aug; 22(5):352-9. PubMed ID: 20650382
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Awake orotracheal intubation under airway topical anesthesia using the Bonfils in patients with a predicted difficult airway.
    He N; Xue FS; Xu YC; Liao X; Xu XZ
    Can J Anaesth; 2008 Dec; 55(12):881-2. PubMed ID: 19050098
    [No Abstract]   [Full Text] [Related]  

  • 33. The Glidescope system: a clinical assessment of performance.
    Rai MR; Dering A; Verghese C
    Anaesthesia; 2005 Jan; 60(1):60-4. PubMed ID: 15601274
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Managing the difficult airway: a survey of residency directors and a call for change.
    Reeder TJ; Brown CK; Norris DL
    J Emerg Med; 2005 May; 28(4):473-8. PubMed ID: 15837035
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Tracheal intubation by inexperienced medical residents using the Airtraq and Macintosh laryngoscopes--a manikin study.
    Maharaj CH; Ni Chonghaile M; Higgins BD; Harte BH; Laffey JG
    Am J Emerg Med; 2006 Nov; 24(7):769-74. PubMed ID: 17098095
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Airway Scope for difficult intubation.
    Asai T; Enomoto Y; Okuda Y
    Anaesthesia; 2007 Feb; 62(2):199. PubMed ID: 17223831
    [No Abstract]   [Full Text] [Related]  

  • 37. Comparison of a single-use GlideScope Cobalt videolaryngoscope with a conventional GlideScope for orotracheal intubation.
    Jones PM; Turkstra TP; Armstrong KP; Armstrong PM; Harle CC
    Can J Anaesth; 2010 Jan; 57(1):18-23. PubMed ID: 19882199
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The learning curve for videolaryngoscopy.
    Butchart AG; Young P
    Anaesthesia; 2010 Nov; 65(11):1145-6; author reply 1146-7. PubMed ID: 20946399
    [No Abstract]   [Full Text] [Related]  

  • 39. Awake fiberoptic intubation using an optical stylet in an anticipated difficult airway.
    Kovacs G; Law AJ; Petrie D
    Ann Emerg Med; 2007 Jan; 49(1):81-3. PubMed ID: 17141147
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Developments in laryngoscopy and tracheal intubation: videogames and practical tools.
    Randell T; Antila H
    Acta Anaesthesiol Scand; 2008 Jan; 52(1):3-5. PubMed ID: 18173430
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.