These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 21648049)

  • 1. Very late thrombosis in a bare metal stent: mechanistic analysis from optical coherence tomography.
    Qian J; Yang YJ
    Catheter Cardiovasc Interv; 2012 Feb; 79(2):288-90. PubMed ID: 21648049
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of lipid-rich plaque inside bare metal stent: possible mechanism of late stent thrombosis? An optical coherence tomography study.
    Hou J; Qi H; Zhang M; Ma L; Liu H; Han Z; Meng L; Yang S; Zhang S; Yu B; Jang IK
    Heart; 2010 Aug; 96(15):1187-90. PubMed ID: 20639235
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Very late bare metal stent thrombosis due to neoatherosclerotic plaque rupture: an optical coherence tomography finding.
    Bennett J; Coosemans M; Adriaenssens T
    Heart; 2012 Oct; 98(19):1470. PubMed ID: 22649093
    [No Abstract]   [Full Text] [Related]  

  • 4. A rare mechanism of very late bare metal stent thrombosis--role of optical coherence imaging in its evaluation and management.
    Subban V; Bell B; Raffel OC; Small A; Savage M; Incani A; Walters DL
    Heart Lung Circ; 2014 Feb; 23(2):190-2. PubMed ID: 23721696
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Disruption of atherosclerotic neointima as a cause of very late stent thrombosis after bare metal stent implantation.
    Ando H; Ishii H; Yoshikawa D; Uetani T; Amano T; Murohara T
    Am J Cardiol; 2012 Feb; 109(3):448-9. PubMed ID: 22071214
    [TBL] [Abstract][Full Text] [Related]  

  • 6. OCT analysis in patients with very late stent thrombosis.
    Kang SJ; Lee CW; Song H; Ahn JM; Kim WJ; Lee JY; Park DW; Lee SW; Kim YH; Mintz GS; Park SW; Park SJ
    JACC Cardiovasc Imaging; 2013 Jun; 6(6):695-703. PubMed ID: 23643282
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stent malapposition, as a potential mechanism of very late stent thrombosis after bare-metal stent implantation: a case report.
    Higuma T; Abe N; Hanada K; Yokoyama H; Tomita H; Okumura K
    Cardiovasc Revasc Med; 2014 Apr; 15(3):178-81. PubMed ID: 24139450
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optical coherence tomography visualization of a ruptured plaque after bare-metal stent implantation.
    Kim S; Ko YG; Shin DH; Kim JS; Kim BK; Choi D; Hong MK; Jang Y
    Can J Cardiol; 2012; 28(4):516.e11-2. PubMed ID: 22326713
    [No Abstract]   [Full Text] [Related]  

  • 9. [Value of the optical coherence tomography in the treatment guided of the stent failure. Case report].
    Macías E; Tellez A; Ochoa J; Ortíz JE
    Arch Cardiol Mex; 2014; 84(4):305-9. PubMed ID: 25108456
    [TBL] [Abstract][Full Text] [Related]  

  • 10. First results of the DEB-AMI (drug eluting balloon in acute ST-segment elevation myocardial infarction) trial: a multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in primary percutaneous coronary intervention with 6-month angiographic, intravascular, functional, and clinical outcomes.
    Belkacemi A; Agostoni P; Nathoe HM; Voskuil M; Shao C; Van Belle E; Wildbergh T; Politi L; Doevendans PA; Sangiorgi GM; Stella PR
    J Am Coll Cardiol; 2012 Jun; 59(25):2327-37. PubMed ID: 22503057
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Very late stent thrombosis derived from thin-cap neoatheroma and fibroatheroma with plaque rupture assessed by optical coherence tomography.
    Kim Y; Jeong MH; Kim MC; Sim DS; Hong YJ; Kim JH; Ahn Y
    Cardiol J; 2017; 24(6):704-705. PubMed ID: 29297582
    [No Abstract]   [Full Text] [Related]  

  • 12. Very late stent thrombosis related to incomplete neointimal coverage or neoatherosclerotic plaque rupture identified by optical coherence tomography imaging.
    Amabile N; Souteyrand G; Ghostine S; Combaret N; Slama MS; Barber-Chamoux N; Motreff P; Caussin C
    Eur Heart J Cardiovasc Imaging; 2014 Jan; 15(1):24-31. PubMed ID: 23720378
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optical Frequency Domain Imaging of Very Late Stent Thrombosis Following Bare-Metal Stent Implantation for Acute Myocardial Infarction.
    Masuda S; Shibui T; Kawamura R; Saiki H; Hata A
    Int Heart J; 2018 Jan; 59(1):209-212. PubMed ID: 29279529
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Very late thrombosis in a bare metal stent: an under-recognized problem.
    Fineschi M; Gori T
    Can J Cardiol; 2008 Feb; 24(2):e6-7. PubMed ID: 18273479
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Increased thin-cap neoatheroma and periprocedural myocardial infarction in drug-eluting stent restenosis: multimodality intravascular imaging of drug-eluting and bare-metal stents.
    Ali ZA; Roleder T; Narula J; Mohanty BD; Baber U; Kovacic JC; Mintz GS; Otsuka F; Pan S; Virmani R; Sharma SK; Moreno P; Kini AS
    Circ Cardiovasc Interv; 2013 Oct; 6(5):507-17. PubMed ID: 24065447
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Very late bare metal stent thrombosis: The role of restenosis.
    Sengül C; Erdoğan T; Dindar I
    Turk Kardiyol Dern Ars; 2010 Jun; 38(4):282-4. PubMed ID: 20935438
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Time does not heal every wound: coronary stent thrombosis of a bare-metal stent more than one decade after its implantation.
    Zomer AC; Zwart B; van Werkum JW; Suttorp MJ
    Platelets; 2009 Dec; 20(8):594-7. PubMed ID: 19857047
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The butler did it! A very late stent thrombosis of TAXUS evaluated with Optical Coherence Tomography.
    Iannaccone M; D'Ascenzo F; Montefusco A; Moretti C; Gaita F
    Int J Cardiol; 2015; 187():141-3. PubMed ID: 25828337
    [No Abstract]   [Full Text] [Related]  

  • 19. Multimodality visualization with 3-dimensional reconstruction of neointimal plaque rupture after bare-metal stent implantation.
    Sudo M; Hiro T; Takayama T; Iida K; Nishida T; Kawano T; Kanai T; Higuchi Y; Hirayama A
    JACC Cardiovasc Interv; 2014 Oct; 7(10):e163-5. PubMed ID: 25240542
    [No Abstract]   [Full Text] [Related]  

  • 20. Excessive stent overhang as an uncommon cause of very late stent thrombosis: Usefulness of optical coherence tomography.
    Rumiz E; Vilar JV; Berenguer A
    Int J Cardiol; 2016 Jan; 203():123-5. PubMed ID: 26519671
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.