BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 21648078)

  • 1. Comparison of monolithic and 1.8-μm RP-18 silica capillary columns using chromatographic data and mass spectrometric identification scores for proteins.
    Rozenbrand J; de Jong GJ; van Bennekom WP
    J Sep Sci; 2011 Aug; 34(16-17):2199-205. PubMed ID: 21648078
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Estimation and optimization of the peak capacity of one-dimensional gradient high performance liquid chromatography using a long monolithic silica capillary column.
    Horie K; Sato Y; Kimura T; Nakamura T; Ishihama Y; Oda Y; Ikegami T; Tanaka N
    J Chromatogr A; 2012 Mar; 1228():283-91. PubMed ID: 22265351
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fast LC separation of a myoglobin digest: a case study using monolithic and particulate RP 18 silica capillary columns.
    Rozenbrand J; van Bennekom WP; Unger KK; de Jong GJ
    Anal Bioanal Chem; 2006 Jul; 385(6):1055-61. PubMed ID: 16736167
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of the gradient kinetic performance of silica monolithic capillary columns with columns packed with 3 μm porous and 2.7 μm fused-core silica particles.
    Vaast A; Broeckhoven K; Dolman S; Desmet G; Eeltink S
    J Chromatogr A; 2012 Mar; 1228():270-5. PubMed ID: 21855077
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance of wide-pore monolithic silica column in protein separation.
    Morisaka H; Kobayashi K; Kirino A; Furuno M; Minakuchi H; Nakanishi K; Ueda M
    J Sep Sci; 2009 Aug; 32(15-16):2747-51. PubMed ID: 19575377
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-efficiency peptide analysis on monolithic multimode capillary columns: Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry.
    Ivanov AR; Horváth C; Karger BL
    Electrophoresis; 2003 Nov; 24(21):3663-73. PubMed ID: 14613191
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Band broadening in fast gradient high-performance liquid chromatography: application to the second generation of 4.6 mm I.D. silica monolithic columns.
    Gritti F; Guiochon G
    J Chromatogr A; 2012 May; 1238():77-90. PubMed ID: 22503619
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improvement of the liquid-chromatographic analysis of protein tryptic digests by the use of long-capillary monolithic columns with UV and MS detection.
    van de Meent MH; de Jong GJ
    Anal Bioanal Chem; 2007 May; 388(1):195-200. PubMed ID: 17393153
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Potential of long capillary monolithic columns for the analysis of protein digests.
    van de Meent MH; de Jong GJ
    J Sep Sci; 2009 Feb; 32(4):487-93. PubMed ID: 19160369
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of pore structural parameters on column performance and resolution of reversed-phase monolithic silica columns for peptides and proteins.
    Skudas R; Grimes BA; Machtejevas E; Kudirkaite V; Kornysova O; Hennessy TP; Lubda D; Unger KK
    J Chromatogr A; 2007 Mar; 1144(1):72-84. PubMed ID: 17084406
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Preparation of 20-microm-i.d. silica-based monolithic columns and their performance for proteomics analyses.
    Luo Q; Shen Y; Hixson KK; Zhao R; Yang F; Moore RJ; Mottaz HM; Smith RD
    Anal Chem; 2005 Aug; 77(15):5028-35. PubMed ID: 16053318
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monolithic silica columns of various format in automated sample clean-up/multidimensional liquid chromatography/mass spectrometry for peptidomics.
    Machtejevas E; Andrecht S; Lubda D; Unger KK
    J Chromatogr A; 2007 Mar; 1144(1):97-101. PubMed ID: 17137587
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-efficiency liquid chromatography-mass spectrometry separations with 50 mm, 250 mm, and 1 m long polymer-based monolithic capillary columns for the characterization of complex proteolytic digests.
    Eeltink S; Dolman S; Detobel F; Swart R; Ursem M; Schoenmakers PJ
    J Chromatogr A; 2010 Oct; 1217(43):6610-5. PubMed ID: 20382391
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hydrophilic interaction chromatography using a meter-scale monolithic silica capillary column for proteomics LC-MS.
    Horie K; Kamakura T; Ikegami T; Wakabayashi M; Kato T; Tanaka N; Ishihama Y
    Anal Chem; 2014 Apr; 86(8):3817-24. PubMed ID: 24666247
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Silica particles encapsulated poly(styrene-divinylbenzene) monolithic stationary phases for micro-high performance liquid chromatography.
    Bakry R; Stöggl WM; Hochleitner EO; Stecher G; Huck CW; Bonn GK
    J Chromatogr A; 2006 Nov; 1132(1-2):183-9. PubMed ID: 16920130
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 1 mm ID poly(styrene-co-divinylbenzene) monolithic columns for high-peak capacity one- and two-dimensional liquid chromatographic separations of intact proteins.
    Eeltink S; Dolman S; Detobel F; Desmet G; Swart R; Ursem M
    J Sep Sci; 2009 Aug; 32(15-16):2504-9. PubMed ID: 19557812
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-performance liquid chromatographic enantioseparations on capillary columns containing monolithic silica modified with amylose tris(3,5-dimethylphenylcarbamate).
    Chankvetadze B; Yamamoto C; Kamigaito M; Tanaka N; Nakanishi K; Okamoto Y
    J Chromatogr A; 2006 Mar; 1110(1-2):46-52. PubMed ID: 16476435
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High-speed gradient separations of peptides and proteins using polymer-monolithic poly(styrene-co-divinylbenzene) capillary columns at ultra-high pressure.
    Vaast A; Nováková L; Desmet G; de Haan B; Swart R; Eeltink S
    J Chromatogr A; 2013 Aug; 1304():177-82. PubMed ID: 23885671
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reversed-phase high-performance liquid chromatographic prefractionation of immunodepleted human serum proteins to enhance mass spectrometry identification of lower-abundant proteins.
    Martosella J; Zolotarjova N; Liu H; Nicol G; Boyes BE
    J Proteome Res; 2005; 4(5):1522-37. PubMed ID: 16212403
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-efficiency liquid chromatographic separation utilizing long monolithic silica capillary columns.
    Miyamoto K; Hara T; Kobayashi H; Morisaka H; Tokuda D; Horie K; Koduki K; Makino S; Núñez O; Yang C; Kawabe T; Ikegami T; Takubo H; Ishihama Y; Tanaka N
    Anal Chem; 2008 Nov; 80(22):8741-50. PubMed ID: 18947204
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.